My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
7910
>
2300 - Underground Storage Tank Program
>
PR0231660
>
COMPLIANCE INFO 2002-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2022 4:12:56 PM
Creation date
11/5/2018 6:43:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2013
RECORD_ID
PR0231660
PE
2361
FACILITY_ID
FA0003733
FACILITY_NAME
NORTH SIDE SHELL
STREET_NUMBER
7910
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
07949006
CURRENT_STATUS
02
SITE_LOCATION
7910 LOWER SACRAMENTO RD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOWER SACRAMENTO\7910\PR0231660\COMPLIANCE INFO 2002-2013.PDF
QuestysFileName
COMPLIANCE INFO 2002-2013
QuestysRecordDate
8/1/2017 3:46:12 PM
QuestysRecordID
3538774
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification-PA of 3 <br /> Site Address: 7910 Sacramento Rd. @ Hammer Lane Date of Testing/Servicing: 6123104 <br /> D. Results of Testing l Servicing <br /> Software Version Installed: 119.02 <br /> Complete the following checklist: <br /> g Yes ❑ No* Is the audible alarm operational? <br /> 85 Yes p o Is the visual alarm operatio <br /> g Yes ❑ o Were all sensors visually inspected, functionally tested, and confirmed operational? <br /> M Yes ❑No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> gS Yes ❑ o arms are relayed to a remote monitoring station, is 0 communications equipment e.g. modem) <br /> ❑ NIA operational? <br /> IN Yes ❑ No* For pressurized piping systems, does the ter ine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to operate, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down?(Check all that apply) IN Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? M Yes ❑No <br /> ❑Yes ❑ No For tank systems that utilize the monitoring system as the primary tank overfill warning device i.e,no <br /> pq N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so, at what percent of tank capacity does the alarm trigger? 0 % <br /> ❑Yes* A No Was any monitoring equipment replaced. If yes,identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E, below. <br /> ❑ es JN No as aqui oun insi e any secon ry containment systems -esigned as dry systems. (Check all that app y <br /> ❑Product; ❑ Water. If yes, describe causes in Section E,below. <br /> Yes ❑ o as monitoring system set-up reviewed to ensure proper settings.(Attach set-up reports, if applicable.) <br /> 7 7es ❑ o Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below, describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br />
The URL can be used to link to this page
Your browser does not support the video tag.