My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
3550
>
2300 - Underground Storage Tank Program
>
PR0505827
>
COMPLIANCE INFO_1997-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:05:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2007
RECORD_ID
PR0505827
PE
2361
FACILITY_ID
FA0007030
FACILITY_NAME
VALLEY PACIFIC HWY 99 CARDLOCK
STREET_NUMBER
3550
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17916043
CURRENT_STATUS
01
SITE_LOCATION
3550 S HWY 99
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\3550\PR0505827\COMPLIANCE INFO 1997-2007.PDF
QuestysFileName
COMPLIANCE INFO 1997-2007
QuestysRecordDate
6/21/2017 4:01:59 PM
QuestysRecordID
3452124
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> Software Version Installed: <br /> Complete the following checldist: <br /> es ❑ No* is the audible alarm operational? 1 <br /> Yes ❑ No* Is the visual alarm operational? <br /> es Q No* Were all sensors visually inspected functionally tested,and confumed operational? <br /> 1k es ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper ration? <br /> Yes ❑ No' If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> Q N/A operational? <br /> -Yes Q No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A Monitoring system detects a leak,fails to opepte,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply)<CI==i=&Cispenser Containment Sensors. - <br /> Did you confirm positive shutdown due to leakonnection? ❑Yes; ❑No. <br /> ""Yes O No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> ❑ N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audibl. the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? <br /> ❑ Yes* No Was any monitoring equipment replaced? if yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section I3,below. <br /> l�Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)Q <br /> Product; Q W airs. >f s,describe causes is Section E,below. <br /> ❑ Nc* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> Yes O No* Is all monitoring ui mentoperational per manufacturer's s ificadons? <br /> •In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments- <br /> Page 2 of 3 83101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.