My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:14:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2012-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A 53/A 5310 - 06a <br /> 16.1.2 For plain-end pipe lighter than extra-strong weight,it and any flaking or cracking of the zinc coating shall not be <br /> shall be permissible for not more than 5 %of the total number considered cause for rejection. If galvanized pipe is bent or <br /> of pipe to be in lengths of 12 to 16 It [3.66 to 4.88 m]. otherwise fabricated to a degree that causes the zinc coating to <br /> 16.1.3 Pipe of extra-strong weight or heavier shall be in stretch or compress beyond the limit of elasticity,some flaking <br /> random lengths of 12 to 22 ft (3.66 to 6.71 m], except that it of the coating is acceptable. <br /> shall be permissible for not more than 5%of the total of pipe <br /> to be in lengths of 6 to 12 ft [1.83 to 3.66 m]. 18. Inspection <br /> 16.1.4 For extra-strong weight or lighter pipe ordered in <br /> double-random lengths, the minimum lengths shall be not less 18.1 The inspector representing the purchaser shall have <br /> than 22 it [6.71 m] and the minimum average length for the entry, at all times while work on the contract of the purchaser <br /> order shall be not less than 35 it [10.67 m]. is being performed, to all parts of the manufacturer's works <br /> 16.1.5 For pipe heavier than extra-strong weight ordered in that concern the manufacture of the pipe ordered. The manu- <br /> lengths longer than single random, the lengths shall be as facturer shall afford the inspector all reasonable facilities to be <br /> agreed upon between the manufacturer and the purchaser. satisfied that the pipe is being furnished in accordance with this <br /> 16.1.6 If pipe is furnished threaded and coupled, the length specification.All tests(except product analysis)and inspection <br /> shall be measured to the outer face of the coupling. shall be made at the place of manufacture prior to shipment, <br /> unless otherwise specified,and shall be so conducted as not to <br /> 17. Galvanized Pipe interfere unnecessarily with the operation of the works. <br /> 17.1 Galvanized pipe ordered under this specification shall <br /> be coated with zinc inside and outside by the hot-dip process. 19. Rejection <br /> The zinc used for the coating shall be any grade of zinc 19,1 The purchaser is permitted to inspect each length of <br /> conforming to Specification B 6. pipe received from the manufacturer and,if it does not meet the <br /> 17.2 Weight(Mass)per Unit Area of Coating-The weight requirements of this specification based upon the inspection <br /> (mass) per unit area of zinc coating shall be not less than 1.8 and test method as outlined in the specification,the length shall <br /> oz/ft'[0.55 kg/m2] as determined from the average results of be rejected and the manufacturer shall be notified.Disposition <br /> the two specimens taken for test in the manner prescribed in <br /> 17.5 and not less than 1.6 oz/ft'-[0.49 kg/m'] for each of these of rejected pipe shall be a matter of agreement between the <br /> manufacturer and the purchaser. <br /> specimens. The weight (mass) per unit area of coating, ex- 19.2 Pipe found in fabrication or in installation to be <br /> pressed in ounces per square foot[kilograms per square metre] <br /> shall be calculated by dividing the total weight(mass)of zinc, unsuitable for the intended use, under the scope and require- <br /> inside plus outside,by the total area,inside plus outside,of the mems of this specification,shall be set aside and the manufac- <br /> surface coated. Each specimen shall have not less than 1.3 turer notified. Such pipe shall be subject to mutual investiga- <br /> oz/ft'[0.40 kg/mz]of zinc coating on each surface,calculated tion as to the nature and severity of the deficiency and the <br /> by dividing the total weight(mass)of zinc on the given surface forming or installation, or both,conditions involved. Disposi- <br /> (outside or inside)by the area of the surface coated(outside or tion shall be a matter for agreement. <br /> inside). <br /> 17.3 Weight (Mass) per Unit Area of Coating Test-The 20. Certification <br /> weight(mass)per unit area of zinc coating shall be determined 20.1 The manufacturer or supplier shall, upon request, <br /> by stripping tests in accordance with Test Method A 90/A 90M. furnish to the purchaser a certificate of compliance stating that <br /> 17.4 Test Specimens-Test specimens for determination of the material has been manufactured, sampled, tested, and <br /> weight (mass) per unit area of coating shall be cut approxi- inspected in accordance with this specification (including <br /> mately 4 in. [100 mm] in length. year-date), and has been found to meet the requirements. <br /> 17.5 Number of Tests-Two test specimens for the determi- 20.2 Test Report-For Types E and S, the manufacturer or <br /> nation of weight(mass)per unit area of coating shall be taken, supplier shall furnish to the purchaser a chemical analysis <br /> one from each end of one length of galvanized pipe selected at report for the elements given in Table I. <br /> random from each lo[ of 500 lengths, or fraction thereof, of 3 ED!-A certificate of compliance or test report printed <br /> each size. <br /> 17.6 Rerests-If the weigh[ (mass) per unit area of coating From, or used in, electronic form from an electronic data <br /> of any lot does not conform to the requirements specified in interchange(EDI)transmission shall be regarded as having the <br /> 17.2,retests of two additional pipes from the same lot shall be same validity as a counterpart printed in the certifier's facility. <br /> made, each of which shall conform to the specified require- The use and format of the EDI document are subject to <br /> mens. agreement between the purchaser and the manufacturer or <br /> 17.7 If pipe ordered under this specification is to be galva- supplier. <br /> nized, the tension, flattening, and bend tests shall be made on Non 7-EDI is the computer to computer exchange of business <br /> the base material before galvanizing, if practicable. If speci- information in a standard format such as ANSI ASC X12. <br /> fied, results of the mechanical tests on the base material shall <br /> be reported to the purchaser. If it is impracticable to make the 20.4 Notwithstanding the absence of a signature, the orga- <br /> mechanical tests on the base material before galvanizing, it nization submitting the certificate of compliance or test report <br /> shall be permissible to make such tests on galvanized samples, is responsible for its content. <br /> 8 <br />
The URL can be used to link to this page