My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:14:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2012-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps Lj ____ <br /> Fill Riser Containment Sumps are Present,but were Not Tested❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑ Other(Specifi) _ <br /> Test Method Used: ❑ Pressure ❑ vacuum ® Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: INCON TS-STS Equipment Resolution:0.0001 <br /> Fill Sump #87 Fill Sump#89 Fill Sump#91 Fili Sum # <br /> Sump Diameter: 42" 42" 42" <br /> Sum De the _ 63" 64" 68" <br /> Height from Tank Top to Top of 0 0 0 <br /> Highest Piping Penetration: _ <br /> Height from'rank Top to Lowest 37" 37" 36" <br /> Electrical Penetration: _ <br /> Condition of sump prior to testing, FAIR FAIR FAIR <br /> Portion of Sump Tested 39" 39" 38" <br /> Sump Material: FG FG FG <br /> Wait time between applying 15 MIN 15 MIN 15 MIN <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Stait'rime: 3:00 3:39 __- 3:00 <br /> Initial Reading(Rj......... 4.5491 4.9115 3.7768 <br /> Test End Time: 3:15 3:54 3:t5 <br /> Final Reading R 4.5492 _4.9110 3.7770 <br /> Test Duration: 15 MIN 15 MIN 15 MIN <br /> Change in Reading,(RF-Ri): 0.0001 0.01105 0.0002 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 <br /> Test-Result: Pass Fail Pass Fitit ❑Fa <br /> Pass Fail {Pass il <br /> Is there a sensor in the sump? Yes El No _Yes 0 No Yes Nn Li Yes Lj No <br /> Does the sensor alarm when either ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA ❑Yes❑No❑NA <br /> product or water is detected? <br /> Was sensor removed for testing? Yes No NA Yes No NA ZYesEjNoLNA Ej Yes No NA <br /> Was sensor properly replaced and Z Yes Lj No ETNA Z Yes Lj No Lj NA Yes No NA Yes No NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior io testing, and recommended jbUow-up for failed tests) <br /> RECEI Y EL <br /> NOV 2 5 2N <br /> ENVIRONMENTAL <br /> HFl11Tu r1Cg8OT44rNT <br /> Secondary Containment Test Results 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.