Laserfiche WebLink
MONITOWNG SYSTEM CERTIFICOION <br /> F e By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3 Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be Prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7-ELEVEN#32190,MKT 2368 City: STOCKTON CA Zip:95206 <br /> Site Address: 4943 S.KINGSLEY(FRONTAGE RD) Contact Phone No: 939-0679 <br /> HWY 99 @ ARCH AIRPORT RD Dale of Testing/Service: 06/07/2011 <br /> Facility Contact Person: MGR-LORENA <br /> Make/Model of Monitoring System:TLS 350 Work Order Number: 2281601 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 87 REGULAR Tank ID: 89 PLUS <br /> 71 In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 302 Annular Space or Vault Sensor. Model: 302 <br /> 71 Piping Sumplrrench Sensor(s). Model: 208 Piping Sumprrrench Sensor(s). Model: 208 <br /> X Fill Sump Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: 208 <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: PLLD ❑X Electronic Line Leak Detector. Model: PLLD <br /> X Tank Overfill/High-Level Sensor. Model: FLAPPER ® Tank Overnll/High-Level Sensor. Model: FLAPPER <br /> Other(specify equipment type and model in Section E on page 2). Otherc' equipment <br /> (s pe dY <br /> type and model in Section E on page 2). <br /> Tank ID: TanklD: <br /> In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 302 Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensor(s). Model: 208 Piping Sumpri-rench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model: 208 Fill Sump Senors). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: PLLD <br /> Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: FLAPPER Tank OvefilUHigh-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Othereci s equipment <br /> ( p ty <br /> type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Sensor(s) Model:208 :Xj Dispenser Containment Sensor(s) Model:208 <br /> X7 Shear Valve(s). X Shear Valves) <br /> ❑Dispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> X❑Dispenser Containment Sensor(s) Model:208 21 Dispenser Containment Sensor(s). Model:208 <br /> XO Shear Valve(s). Shearvalve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/10 Dispenser ID: 11/12 <br /> X❑ Dispenser Containment Sensor(s) Model:208 —XI Dispenser Containment Sensor(s). Model:208 <br /> FX Shear Valve(s). :X Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this farm.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up X❑Alarm history report <br /> Technician Name(print): STEVEN WILLEMS Signature: <br /> Certification No.: 836743 License.No.: 743160(Class'A'General Enginering Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 11000 N.MoPac Expressway,suite 500,Austin,TX 78759 Date of Testing/Servicing: 06/07/2011 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/08 <br />