My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2008-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:17:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2009
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2008-2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
300
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> -4- <br /> Vapor Flow Meter Operability Test <br /> 1. Connect a notebook PC — See figure 5-9 of the ISD Install, Setup & Operation <br /> Manual. Run Veeder-Root's "ISD PC Setup Tool", v1.03 or higher, to the <br /> dedicated TLS serial port that is required for ISD reports access. Using the tool, <br /> access the individual fueling point"dispensing event ISD A/C results as needed <br /> in this test procedure. These results are compared to the manually measured <br /> V/L's in the procedure. Training on use of the tool is provided as part of the <br /> Veeder-Root training program for ISD. A trained service technician must be <br /> present when performing this operation. <br /> 2. Select a dispenser and note the fueling point numbers on the data form. Obtain <br /> the vapor flow meter serial number (available from the EVR/ISD Setup Printout— <br /> see Figure 3-6 in the ISD Install, Setup & Operation Manual). Record the serial <br /> number on the data form. <br /> 3. Conduct a Healy EVR Phase I I system V/L test per Exhibit 5 of VR-202-D with <br /> lowest grade fuel available on that dispenser to obtain a V/L result. <br /> 4. Obtain the corresponding ISD A/L value for that V/L test obtained from the TLS <br /> using the "ISD PC Setup Tool". <br /> 5. Compare the ISD A/L value for that dispenser hose to the V/L result (subtract V/L <br /> result from A/L value and note difference on the form). <br /> Pass: If the difference is between -0.15 and +0.15, then the ISD A/L value <br /> is within +/- 0.15 of the V/L result. Circle "Pass" to document that <br /> the ISD flow meter in that dispenser passes and repeat the <br /> procedure beginning at Step 2 for the next dispenser. <br /> Continue: If the ISD A/L value is NOT within +/- 0.15 of the V/L result, then go <br /> to Step 6. <br /> 6. Run two more V/L tests per Exhibit 5 with lowest grade fuel on the same hose <br /> and average the two results with the first V/L result from Step 3. <br /> 7. Obtain the corresponding two ISD A/L values from the TLS and average the two <br /> values with the first ISD A/L value from Step 4. <br /> 8. Compare the average of the 3 ISD values for that hose to the average of the 3 <br /> V/L results (subtract V/L average from A/L average and note difference on the <br /> form). <br /> Healy Phase 11 EVR System Including Veeder-Root ISD, Exhibit 9—VR-202-D <br />