My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 TO PRESENT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2016 TO PRESENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:23:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 TO PRESENT
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2016 TO PRESENT.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
155
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R E <br /> k . I an <br /> Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at hftp://www.swrcb.ca:gov.)'3! 8 2017 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions within the StateofCalifornia ENVI^('l�lNIE{STAL HEALTI <br /> Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code 0 7 n'p � <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7-ELEVEN#32190,MKT 2368 <br /> Site Address: 4943 S. KINGSLEY(FRONTAGE RD)HWY 99 @ ARCH AIRPORT RD <br /> Bldg. No.: <br /> Facility Contact Person: MGR-LORENA City: STOCKTON Zip: 95206 <br /> Contact Phone No.: 209-939-0679 <br /> Make/Model of Monitoring System: Veeder Root TI-S-350 <br /> B.Inventory of Equipment Tested/Certified Date of Testing/Servicing! 4/11/2017 <br /> Check the appropriate boxes to indicatespecific aqui 3ment ins ected serviced: <br /> Tank ID: T4-RUL Tank ID: T5-MUL <br /> r In-Tank Gauging Probe. Model: MAG r7l In-Tank Gauging Probe. Model: MAG <br /> P Annular Space or Vault Sensor. Model: 794380 302 P Annular Space or Vault Sensor. Model: 794380 302 <br /> P_ Piping Sump/Trench Sensor(s). Model: 794380-208 r Piping Sump/Trench Sensor(s), Model: 794380-208 <br /> S7 Fill Sump Sensor(s). Model: 794380-208 r Fill Sump Sensor(s). Model: 208 <br /> Mechanical Line Leak Detector. Model <br /> 794380 <br /> Electronic Line Leak Detector. Model: Veeder Root PLLD- r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: Veeder Root PLLD- <br /> r Tank Overfill/High-Level Sensor.Model FLAPPERS r Tank Overfill/High-Level Sensor.Model: FLAPPERS <br /> Other(specify,a ui ment type and model in Section E on Pa e 2 . <br /> Other(specifyequipment a and model in Section E on Pa e 2). <br /> Tank ID: T6-PUL Tank ID: <br /> In-Tank Gauging Probe. Model: ETMAGI✓ Annular Space or Vault Sensor. Model -302 r In Tank Gauging Probe. Model: <br /> P— Piping Sump/Trench Sensor(s). Model: 794380-208r Annular Space or Vault Sensor. Model: <br /> r Piping Sump/Trench Sensor(s). Model: <br /> IO Fill Sump Sensor(s). Model: 794380-208 r Fill Sump Sensor(s). Model: <br /> r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: Veeder Root PLLD- r Mechanical Line Leak Detector. Model: <br /> tv Tank Overfill/High-Level Sensor.Model: FLAPPERS r Electronic Line Leak Detector. Model: <br /> Other(specifyequipment a and model in Section E on Pae 2). r Tank Overfill/High Level Sensor.Madel; <br /> Other(specify a ui ment a and model in Section E on Pa e 2 . <br /> Dispenser 1/2 Dispenser <br /> ID: ID: 314 <br /> Iw Dispenser Containment Sensor(s).Model: 794380-206 17 <br /> Dispenser Containment Sensors),Model: 794380-208 <br /> W Shear Valve(s). W Shear Valve(s). <br /> Fr Dispenser Containment Float(s)and Chain(s). <br /> �' Dispenser Containment Float(s)and Chain(s).. <br /> Dispenser 516 <br /> Ip: Dispenser 7/8 <br /> ID: <br /> (v Dispenser Containment Sensor(s).Model: 794380-208 <br /> r Dispenser Containment Sensor(s).Model: 794380-208 <br /> W Shear Valve(s). � Shear Valve(s). <br /> F Dispenser Containment Float(s)and Chain(s). <br /> r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 9/10 Dispenser <br /> ID. ID: 11/42 <br /> F Dispenser Containment Sensor(s).Model: 794380-208 <br /> [v Dispenser Containment Sensor(s).Madel: 794380-208 <br /> Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). f Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Irdude information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines,Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):I%5ystem set- <br /> up P Alarm history report <br /> Technician Name(print): Jesus Saldivar <br /> Signature: <br /> Certification No.: B45334 License. No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)80011633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 <br /> Date of Testing/Servicing: 4/11/2017 <br /> Monitoring System Certification Page 1 of 3 <br /> 12/D7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.