Laserfiche WebLink
8 <br /> 4 SUMP LID <br /> 26" I.D. <br /> TYP <br /> 27. 3/8". OD <br /> WATER TIGHT COVER <br /> - - - — • • :- -.- - _ 3/4" CONDUIT J BOX - .SEALING BAND NOTE:. <br /> CLAMP CONTRACTOR SHALL BE HELD RESPONSIBLE <br /> w b <br /> • • TO LEAK DETECTION MONITOR PAN`' � SEAL: OFF FOR PROPER INSTALLATION PREPARATION .PER T O , <br /> rp{— MANUFACTURERS INSTRUCTIONS AND SHALL <br /> 3. MIN 2 CONDUCTOR #18 SHIELDED CABLE REINSTALL SUMPS IF HYDROSTATIC TESTING E .� O <br /> IN. RIGID METAL OR PVC SGH. 40 CONDUIT. I SHOWS LEAKING IN THIS AREA OF THE SUMP. E L- Q ['1� <br /> 26' I.D. ACCESS lLJ iViCl <br /> SCR'D fBLACKOSTEEL 2 WIRE SHIELDED CABLE - OPENING y C ,� <br /> 23 3/4" CONDUIT TO TURBINE 3" PVC PIPE. OPEN RISER TOP E U �� •C <br /> AT BOTTOM MOUNTED F.R.P.`RISER TOP <br /> TO SUMP WALL LZ W <br /> 8A 8 O 48" ID SEE TOP JOINT - - ,�` V W <br /> 9 J-BOX SEAL ANY PENETRATION �� �� <br /> MADE INTO SUMP ADHESIVE CC <br /> 24 TEMP. ALIGNMENT SPACE y, I (SUPPLIED W/ <br /> ATTACHED IN FIELD TO KIT) Q C C r <br /> 10 21 20 MANHOLE SKIRT (TYP4 PLCS) "� I <br /> REMOVE AFTER INSTALLATION I I <br /> 48' SUMP I PRODUCT PI ING 48" SUMP - 25 5 8" <br /> - - - -" — J3" _ I `— _ ^y-SLIP ON V � � � <br /> 'gyp 2" BELL & FNPT O i ACCESS OPENING MIN RISER = .� <br /> 3 ADAPTOR 48" I.D. F.R.P. H5 - ~ <br /> VEEDER ROOT COLLAR RISER SEE V Q <br /> LIQUID SENSOR ,d — — ABOVEOTE O O <br /> 22 ADHESIVE <br /> 42' I.D. F.R.P. COLLAR (( ^L <br /> 1 LAMINATED DIRECTLY ON `� WSy KIIT)EO RISER N 1.L CO <br /> TANK BY MANUFACTURER <br /> 1" MIN. FROM BOTTOM OF SUMP AN IN FIELD COLLAR I I ADHESIVE O /O/^^ <br /> LOCATED AT SIDE OF PRODUCT LINE I I BONDED I KSUPPLIED W/ C W <br /> ENTRY BELOW LEVEL OF BOTTOM OF L T)) <br /> LOWEST PENETRATION FITTING. T0: TANK I A � ) <br /> P <br /> I. _ FIELD W V� <br /> � LY.. i <br /> NOTE: ONLY PRODUCT PIPING LAY-U <br /> cd <br /> IS SHOWN IN THIS VIEW JOINT DETAILS Q U <br /> FOR CLARITY <br /> Sump Section Trbine Side Sump Riser Standard <br /> �� Liquid Sensor at Turbine Sump ��GT�TO <br /> dor E <br /> NOT TO SCALE: 1 SCALE LL. <br /> NOT TO SCALE: ^^@ <br /> J <br /> NOTE: <br /> THE LOCATION OF THE VENT DISCHARGE C <br /> SHALL BE 30" ABOVE ROOF AND SHALL ^, <br /> NOT BE WITHIN 5 FEET OF ANY BUILDING Y/ <br /> OPENING (I.E. DOOR WINDOW, ETC.) - <br /> ENTS SHALL BE INSTALLED IN ACCORDANCE E <br /> H UNIFORM FIRE CODE REQUIREMENTS. 40 VENT CAP ^^`` <br /> LU <br /> Uz <br /> TILE _j . <br /> �- <br /> J,3, z <br /> W <br /> ) 2" VENT LINES A\ <br /> 0 RISERS COMMON EXTRACTOR/O V�J: <br /> FLOAT VENT VALVE <br /> .ASSEMBLY FOR STAGE If <br /> ACTIVE SIPHON II . VAPOR RECOVERY AND VENT Q <br /> SLOPE AS SHOWN ON <br /> G _ - <br /> DETAIL #10 ION DWTK3-2 1-5//8" U UT BOLT - - C <br /> TO WAPIPING LOCATED IN SUMP (TYP.)ALL Nz <br /> B 20 21 DUCT UNISTRUT CLAMP <br /> g 3" <br /> TK3-1 <br /> 164A., 1/2" <br /> EE NOTE Rf f <br /> F' V SEE NOTE 3" 3" z <br /> J - Q •Q. <br /> SUMP LIQUID M N R NG 18 �• 2" VENT 2 iv 2N LS FRO io 3.. CO. O <br /> SEE NOl �N'� �V `_�{ J. <br /> 11 10 TYPICAL WALL TK-1 v Q C <br /> (4) 2" GALV. VENT RISER SECTION <br /> 24 11 PPCO NT TO MATCH BUILDING EOM' il\ = V <br /> NEW NION I :5^J�Np 87 TK-2 rCO z-� <br /> ISCW CK STEE 20 �c��A C 0 Cd <br /> 87 <br /> 5 GALV. RISER PRIMED TK-3 U 0. <br /> AND WRAPPED TO <br /> END TANK CONNECTION FOR SIPHON GRADE (TYP.) 7/8"STUCCO <br /> SYSTEM SHOWN HERE. SEE DETAILS <br /> 92 <br /> �6 AND #7 ON DWG. TK3-2 FOR TURBINE (Q Q <br /> NEW NION ( QU <br /> E AND PASSIVE SIDE CONNECTIONS <br /> SCR' L CK STEE FINISH GRADE FINISHED FLOOR <br /> 2" FROM <br /> x x <br /> B22 8 K D FITTI x xxx <br /> TK3-1 SE TE #1 SLOPE 1`4" PER FOOT. <br /> TO TANKS r--- x FOOTING <br /> z m P x 3 <br /> 2" ENT LINE • EARTH q� 2 N o...: <br /> F ANK PO N " � Eowa <br /> 2" GALV. SWI NT o mwd <br /> NOTES: Vent and Vapor Recovery gi2 x U I I <br /> " F.G. BELL X MALE a o m m <br /> 1. SUMP PIPING PENETRATIONS: PIPING PENETRATIONS SHALL BE MADE USING ADAPTER Schematic lkl J 8 v .P m <br /> BULKHEAD FITTINGS (ENVIRON). ELECTRICAL PENETRATIONS SHALL BE MADE WITH <br /> APPROPRIATE WATERTIGHT COMPRESSION FITTINGS WITH SEAL-OFFS. (i.e. ENVIRON). <br /> (THIS IS THE PREFERRED VENT LOCATION OPTION) NOT TO SCALE: <br /> 2. TURBINE SUMP SENSOR: SEE DETAIL #1, SHEET TK3-1. FOR LIQUID SENSOR <br /> DETAILS. SENSOE TO BE MOUNTED AT SIDE OF TANK WHERE PRODUCT PENETRATIONS O pp master releeae date <br /> INTO SUMP IS MADE AND BELOW THE LOWEST PENETRATION FITTING IN THE SUMP .Vent Risers at Building <br /> AREA. <br /> Sump Plan View 4 DATE pr4exe. dndnby <br /> C ' NOT T0: SCALE: <br /> NOT TO SCALE: ,. .. PEiiMT <br /> pf01°Ct /Iacft <br /> -0595 <br /> CONBL: . ehaat(1b <br /> TK3-1 <br /> of <br /> AR994/994TK31.DWG <br />