My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
14800
>
2300 - Underground Storage Tank Program
>
PR0231600
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 10:36:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0231600
PE
2361
FACILITY_ID
FA0000957
FACILITY_NAME
LATHROP GAS & FOOD MART*
STREET_NUMBER
14800
Direction
S
STREET_NAME
STATE ROUTE 99
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19702004
CURRENT_STATUS
02
SITE_LOCATION
14800 S HWY 99 RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\N\HWY 99\14800\PR0231600\COMPLIANCE INFO 2009-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.or-q/ehd/unitiii.html <br /> CONTINUATION FORM Page: 4 of 4 <br /> OFFICIAL INSPECTION REPORT Date: 12/27111 <br /> Facility Address: Lathrop Gas & Food 14800 S. Hwy 99 Manteca, CA 95335 Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> located to detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to be able <br /> to detect a leak at the earliest possible opportunity. During the inspection the technician repositioned the <br /> sensors to the correct side of the tank sump saddle. Continue to ensure that the monitoring equipment is <br /> maintained to be able to detect a leak at the earliest possible opportunity. Corrected on site. <br /> 310. Liquid was observed in the #112, 314, and 516 dispenser sumps. If water could enter into the <br /> secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br /> Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous waste <br /> regulations, and manage it accordingly. Ensure that the tank top sumps are maintained free of liquid. <br /> 311. The 91 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable <br /> of detecting a 3-gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, and <br /> certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and obtain a <br /> permit within one business day from the EHD. If the failed leak detector can't be replaced immediately, <br /> there is a possibility that the 91 UST system may be red tagged to prevent fuel inputs. <br /> 313. The 87 direct-bury spill container failed when tested. All spill containers shall have a minimum <br /> capacity of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. <br /> Immediately discontinue deposition of petroleum into this tank until the component is repaired or <br /> replaced by a properly licensed, trained, and certified contractor under permit and inspection of the EHD. <br /> If the spill container can't be replaced immediately, there is a possibility that the 87 UST system may be <br /> red tagged to prevent fuel inputs. <br /> 314. The mechanical flapper used as the overfill prevention system is being overridden by a stick placed <br /> in the drop tube on the 87 UST. Immediately discontinue deposition of petroleum into this tank until the <br /> stick is removed by a properly licensed, trained, and certified contractor under permit and inspection of <br /> the EHD. If the overfill prevention system can't be returned to normal function immediately, there is a <br /> possibility that the 87 UST system may be red tagged to prevent fuel inputs. <br /> Note: Technician on site verified to the business owner that ElitelV will obtain a permit from the EHD and <br /> and address the above noted violations. Verified "All Functions Normal" on the monitoring panel before <br /> leaving the facility. � SIL'�o . <br /> I <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation by 1-27-11. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAIU14G TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME T EHD'S CURRENT HOURLY RATE, <br /> EHD Inspector: Received Title: <br /> Aris Cacapit (209) 468-3453 <br /> CONTINUATION FORM <br /> EHD 23-02-003 Rev 07112111 <br />
The URL can be used to link to this page
Your browser does not support the video tag.