My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1987-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NEWTON
>
4051
>
2300 - Underground Storage Tank Program
>
PR0231868
>
COMPLIANCE INFO 1987-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2024 4:52:41 PM
Creation date
11/5/2018 10:43:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-2011
RECORD_ID
PR0231868
PE
2361
FACILITY_ID
FA0004045
FACILITY_NAME
AT&T California - UER47
STREET_NUMBER
4051
STREET_NAME
NEWTON
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
4051 Newton Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\N\NEWTON\4051\PR0231868\COMPLIANCE INFO 1987-2011 .PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
205
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> MONIT,tING SYSTEM CERTIFI .-ATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited- Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: PACIFIC BELL GEO PAR# UE-R47 CLLC Code: SKTNCAI6 <br /> Site Address: 4051 NEWTON ROAD City: STOCKTON Zip: <br /> Facility Contact Person: CONNIE MITCHELL Contact Phone No.: 209-474-4014 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Service: 8/9/02 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment ins ted/serviced: <br /> Tank ID: 2029 Tank ID: <br /> ®In-Tank Gauging Probe: Model: 847390-107 ❑ht-Tank Gauging Probe: Model: <br /> ®Annular Space or Vault Sensor: Model: 794390-420 ❑Annular Space or Vault Sensor Model: <br /> ®Piping Sump/Trench Sensor(s): Model: 794390-205 ❑Piping Sump/Trench Sensor(s): Model: <br /> ®Fill Sump Sensor(s): Model: 794390-205 []Fill Sump Sensor(s): Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High-level Sensor: Model: ❑Tank Overfill/High-level Sensor: Model: <br /> ❑Other, Specify ui and model in Section E on Page 2 ❑Other, Specify ui and model in Section E on Page 2 <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe: Model: ❑In-Tank Gauging Probe: Model: <br /> ❑Annular Space or Vault Sensor: Model: ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s): Model: ❑Piping Sump/Trench Sensor(s): Model: <br /> ❑Fill Sump Sensor(s): Model: ❑Fill Sump Sensor(s): Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High-level Sensor: Model: ❑Tank Overfill/High-level Sensor: Model: <br /> ❑Other,Specify ui . type and model in Section E on Pa e 2 ❑Other,Specify equip. a and model in Section E on Page 2 <br /> Dispenser ID: Dispenser ID: <br /> ®Dispenser Containment Sensor: Model: 794390-420 ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Floats and Chains ODispenser Containment Floats and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑In-Tank Gauging Probe: Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Floats and Chains ❑Dis eraser Containment Floats and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑In-Tank Gauging Probe: Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ODispenser Containment Floats and Chain(s) ❑Dis ser Containment Floats and Chain s <br /> -if the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report; (check all that apply): ® System set-up ® isto report <br /> Technician Name(Print): FRED RIDDLES Signature: C�,((JJ <br /> Certification No.: 9579 License No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SYSTEMS Phone No.: (714)560-8222 <br /> Page 1 of 3 03101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.