My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1995 PLAN
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
7647
>
2300 - Underground Storage Tank Program
>
PR0231227
>
INSTALL_1995 PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:24 AM
Creation date
11/6/2018 9:48:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1995 PLAN
RECORD_ID
PR0231227
PE
2361
FACILITY_ID
FA0004033
FACILITY_NAME
BEST CALIFORNIA GAS LTD #172
STREET_NUMBER
7647
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
07748014
CURRENT_STATUS
02
SITE_LOCATION
7647 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\7647\PR0231227\INSTALL PLAN 1995.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> 2'-6" 4'-8• 6'-6" 2'-6" CILBARCO DISPENSING SYSTEM <br /> CANOPY COLUMN CONSOLE INSiALLA110N NOTES <br /> ,I I (WHERE APPLICABLE -+•. 3•_3` 3'_3` N0. 1 E <br /> � ,, • =NONGILBA <br /> © Q 1. TWO IMPACT VALVES AND CLAMPS ARE REQUIRED WHEN A <br /> SEE PLOT PLAN) DISTRIBUTION BOX <br /> F-71 <br /> H - ( RDO DUAL PRODUCT TWIN DISPENSER IS SPECIFIED; THREE <br /> CIRCUIT O D) CONSOLE EACH FOR MULTI PRODUCT DISPENSERS, <br /> it f o BREAKER Q N0. 2 O 2. MOUNTING BRACKET FOR VERTICAL ADJUSTMENT OF VALVE <br /> ,h ,�L--f}}�-7 N 'o PANEL DURING INSTALLAnON. <br /> 3. USE CLAMP SUPPLIED WITH IMPACT VALVE. <br /> I n 4. MOUNTING RODS TO SIDES OF ISLAND TO LOCATE PUMP BOX. <br /> 1 o N LJ-" DISPENSERS <br /> 5. ADAPTER AND IMPACT VALVE TO BE ASSEMBLED TO SUPPLY <br /> 2'-0" 2'-0• VARINC TROUGH PIPE BEFORE CLAMPING VALVE TO ISLAND FORM. <br /> o �J 7 ' O 6. ALL ELECTRICAL WORK TO CONFORM WIn{ LOCAL AND <br /> 7 3'_9' 2'-0 2'-6" 4'-0' S-9" USE HIGHLINE NATIONAL ELECTRICAL CODES AT A MINIMUM. <br /> ,. 8'-3' MODELS 7. ALL WIRES MUST BE CONTINUOUS RUN (NO SPLICES) <br /> 8 88 16'-0• SUBMERSIBLE FROM DISPENSER TO CONSOLE TERMINAL STRIP BOX. <br /> 12 8'-3" / 18' PEDESTAL ISLAND W/ 2/3 DISP. PUMP RELAY Q 8. ALL SPARE WIRES SHOULD BE TAPED AND LOOPED AT <br /> 14 SCALE: 1/4' - 1'-0• O WIRING BLOCK DIAGRAM ENDS AND LABELLED. <br /> SUBMERSIBLE 9. ALL 110VAC TO DISPENSERS MUST BE ON SAME-PHASE. <br /> NOTE 16 - 10. SEE MANUFACTURER'S DRAWINGS INCLUDED WTH <br /> . 11 o PUMPS DISPENSERS FOR FURTHER DETAILS. <br /> 9 I 9 13 Z r{--1 {- 0 11. GENERAL CONTRACTOR TO CALIBRATE DISPENSERS, AND <br /> -L"{J- 1 o a APPLY FOR WEIGHTS AND MEASURES' SEAL. <br /> 10 1 12. ALL CIRCUIT BREAKERS ARE TO BE SW iCHED NEUTRAL <br /> • +.'r I I I TYPE, AND LABELLED NEATLY, ACCORDING TO CIRCUIT. <br /> i� <br /> 5'-4" I 2'-8' � o N 13. CONSOLE TERMINAL STRIP BOX AND/OR PUMP INTERFACE <br /> Z <br /> BOX TO BE MOUNTED IN UTILITY ROOM WITH OTHER <br /> ELEVATION ma w 'd ELECTRICAL APPURTENANCES. <br /> X00 14. SUBMERSIBLE PUMP RELAYS MUST BE USED IF 1 1/2 HP <br /> TYPICAL MPD AND DIESEL DISPENSERS • 16' SOLID ISLAND 2/3 DISP. m PUMP MOTORS ARE INSTALLED. IF NOT SUPPLIED WI(H <br /> S AL T=11=0"- a 0 0 '- m SUBMERSIBLE PUMP, CONSULT THE ENGINEER. <br /> w w w O O U <br /> SCALE: 1/2" r-D~ r ALTERNATE ISLANDS 0 o ' L z z $ = z 0 15, PROVIDE 6' CLEARANCE AROUND ALL SIDES OF CONTROLLER. <br /> a <br /> 6 o b' 8 o O o D i6, 1/2" x 2' ANCHOR BOLTS (4) FOR DISPENSER MOUNTING <br /> 48. w m � m TO BE SUPPLIED BY ISLAND MANUFACTURER. <br /> ` ,22.1/27 - 22.1/2" w ' x o o zO o v vii 17. ALL MATERIAL USED IN ISLAND FORM CONSTRUCTION <br /> 9 h use 21• 21" w a u u ' v v v u o SHALL BE AT LEAST 12 GA, CARBON STEEL. <br /> *. I SALESMAKER-2 - 16.1/2" - 16.1/2' - (4) 13/16• X 1 7/16" w 5 a m o a m o a o <br /> I 2'-8• 2 HOSE 16• - 16" SLOTS FOR w w r r r I-_ <br /> 18. FOR OTHER BUILDING WIDTHS SEE PLOT PLAN. <br /> 9.1 4 u u N N 0 0 0 0 0 u u u <br /> 15.1I/ ANCHOR BOLTS a < z z > > z > > > > �� 19. BACKFILL w./ PEA GRAVEL. SEE 15RSWT FOR BOX MONITORING <br /> 0 0 0 0 0 0 0 0 DETAILS. <br /> . • 13.1/2' - ? > a w o 0 0 0 o o n ¢ ¢ <br /> STEEL i - - 2.1 2" 3) 1 1/2• o O m °vi m s x m a m m a a _ <br /> T- N <br /> TROWEL / w a o a a a 0 a a a a o o REF ITEM SUPPLIED INSTALLED <br /> _ DISPENSING SYSTEM MATERIAL SCHEDULE <br /> _ I FINISH _ SUPPLY UNIONS (� (O� Q - <br /> I O I U CJ V O U tl 3 3 3 3 , 3 <br /> m I a T �-- �• <br /> V '7(4) 13/16•x 1 7/157 3 3 3 3 � 3 3 � ' BY BY - <br /> A SUBMERGED PUMPS OWNER C.C. <br /> ' SLOTS FOR ANCHOR a a a a a a a a a a a ¢ a o <br /> 2'-60 R. :F m m 4.1 8• BOLTS a a Y a a: a a N a a w . m w oz z 0 - <br /> y B PUMP RELAY RED JACKET OWNER G.C. <br /> u u �Q C PAM OWNER G.C, <br /> J 'v ro r u w o 0 o w w 0 DISPENSERS OWNER G.C. <br /> • g �} m} w K a w m m N m o E CONSOLE OWNER G.C. <br /> 3'-7 1 2" 8• R. ` _ ry a' o m ^ a n a o F CONSOLE DATA CABLE O'WNER G.C. <br /> 4" R. <br /> - TYP �i. •w +ra a. as w m 1n =+a m <br /> G DISPENSER CABLE OWNER G.C. <br /> TYP 1/2•CONDUIT RISER 1•VAPOR RECOVERY 1'CONDUIT H DISTRIBUTION BOX OWNERG.C. <br /> 1_ FOR CONDUIT <br /> RISER18•, CONNECTION CONNECTION 0 0 0 0 o 0 0 0 0 0 0 0 0 0 0 0 0 1 PUMP BOX - BENDEL OWNER G.C. <br /> CANOPY UP FROM BASE OR EQUIV. INCLUDES MTG. DKT. _ <br /> 4'-3' -I . • " " a + 2 IMPACT VALVE - DPW 10RM OWNER G.C. <br /> COLUMN SIDE A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 <br /> (WHERE APP.) MPD ADVANTAGE_ � na + - OR EQUIV. INCL. U-BOLI <br /> 12•_3• 2'-0• 2'-6" ._ I, p 3 1 1/2" UNION - CRO. J7, OWNER G.C. <br /> 21• � ^ FURNISHED WITH DISPENSER <br /> 1• CONDUIT 2 + <br /> 10 1 Y- _ TYP 1 w n 1 - o 'O tO e m 4 1 1/2" X 1B" FLEXIBLE OWNER G.C. <br /> NOMINAL BUILDING LENGTH PLUS 21'-4' FOR 685,733 & 1152 BUILOING . 2 9/18' o O o 0 0 o N n a o o m <br /> n + CONNECTOR NON-METALLIC <br /> 0 I 1 1 1 O I i 1 I 1 1 OR STEEL w./SLEEVE <br /> NOMINAL BUILDING LENGTH PLUS 21'-4` FOR 815 & 1225 BUILDINGS. s a a a - a , o a a a a a a a o+ <br /> m z xo 1 . z 5 2' GLASS FIBER PIPE G.C. G.C. <br /> 9 CANOPY COLUMN - !o _ ,_c �u �1 � i� O O o a O z °' + 6 FRP ELBOW, 90° G.C. G.C. <br /> WHERE' APPLICABLE i d ... '° < - m m �S i u � 1F ��a N a + a <br /> N <br /> MPD WIRING °�N m N + � 7 NOZZLE OPW 118 OR EQUIV_ OWNER C.C. <br /> • ' <br /> ,n. O 8 SWIVEL HUSKY 1 + VI OWNER G.C. <br /> 2'-8" R. I kt <br /> N 3 1/ - 14 1 w a w W o a + wr w 9 ISLAND FORM 13• HIGH OWNER G.C. <br /> SINGLE PRODUCT DISPENSER OUTLINE (r 0 ir � => > / <br /> x e 10 HOSE 5 8' X 10 FT. OWNER G.C. <br /> 'A' SIDE F" '' SALESMAKER AND HICHUNE 1 1/2' SUPPLY a � w� o a + m m <br /> -� L�J 21, , OWNER <br /> UNION TYP a w w o o z � tea + n 11 I 12 BREAKAWAY <br /> FILTER HEAD OWNER <br /> HOSE OWNER G.C. <br /> 1 -' I THISPOSITISIDE ON HOSE' 10 1 2• a o p p a 13 CIM-TEK DIESEL FILTER OWNER G.C.14 PUMP OUTLET SWVEI. PUMP MFGG.C. <br /> z ~ w w a + 15 DISPENSER CONTAINMENT BOX <br /> E d N n. j0 j o w w o WESTERN FIBERGLASS OWNER G.C. <br /> 2`-8• 2'-5• LESMAKER-2. io 0 <, m Yu, a m = CONTINUITY m > > ti 16 PIPING PENETRATION SEAL <br /> SINGLE HOSE ,o ,�. o a' mW 0 o j m I WESTERN FIBERGLASS OR EQUIV OWNER G.C. <br /> ., u 0 `�` 1R v u 3 o u v � m d 17 1 t 2 x 12 FLEX CONNECTION <br /> Iu '}' I m a a (� INDICATOR n `r (5 OWNER C.C. <br /> N o w o o .� o o a a '' 1n NON-METALLIC OR STL.w. SLEEVE _ <br /> o it a < E---) 0 18 1 1/2" STEEL COUPLING SCH. G.C. G.0 <br /> "'111 a m o o a 40 GALVANIZED <br /> V) - t� m 19 1 1/2" STEEL PIPE NIPPLE 4" G.C. G.C. <br /> 1 O LONG SCH. 40 GALVANIZED <br /> o w - 3 1' 2• 14' a a a a a a a a a a a a <br /> rzywa I DISPENSER OUTLINE TOSCO NORTHWEST COMPANY <br /> °' ro DUAL PRODUCT o <br /> a I 8a • HICHLINE ONLY 6 6 w w w ? j NOTE A: EACH PI DESIGNATION ABOVE RETAIL MARKETING <br /> PUMP MOUNTING DIAGRAMS _ _ REPRESENTS ONE DISPENSER, DESIGN AND ENGINEERING <br /> mw - N <br /> oz j ` SCALE: 1" 1'-0" z m g n m REGARDLESS OF THE NUMBER OF HOSES DU OHIO 44174 <br /> s r NOTE B: WHERE MORE THAN 6 DISPENSERS <br /> ETAIL AT "i °° ARE INSTALLED, IN CONJUNCTION <br /> L WITH A PAM, ADDITIONAL DISTRIBUTION <br /> 3 BOXES MUST BE ADDED. UP TO 12 <br /> 2'-s• 5'= " I VALVE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DISPENSERS MAY BE WIRED TO ONE DISPENSERS AND ISLANDS <br /> 2 No CONSDISMOLE <br /> IS SED WHEN " DIL°A INE GILBARCO MPD ADVANTAGE <br /> t CONSOLE IS USED.(SEE FIELD ENGINEER). <br /> 0 0 . 0 0 0 0 0 0 0 0 0 0 0 0 <br /> 1 I <br /> CANOPY coluMN 1 ExPAN$-ibN 0 m DISTRIBUTION BOX SALESMAKER 2 AND <br /> z ND QTE 3 JOINT - < o . o <br /> (WHEREAPPLICABLE) TERMINAL STRIPS HIGHLINE MODELS <br /> 3 4' AIR UNE • •' N n o e m f I 1 <br /> i. / f . , :� . :. . ` '. �-. y . .6, o I N a a a 1 tRG-AD <br /> PEA coNCr < < •< < s < < 3 DWG. N0. 13-RG-ADV REV, 13 <br /> 1 J , - i - I ) rj _ .. Ytn 3 3 - i"=1" PLOT SIZE CLEVELAND DETAIL <br /> 'A'' SIDE I I T 9 < - �r N�" x o o �-' �" - D MAY 4, 1987 C C ED BY JGD <br /> o a REVISIONS: A D KO EViSIONS: DATE CKO U <br /> { 1O - ) 6 � ) / � , _ '� > 10. CF{AN GED MP 3 TO MPO' A VAN 2121191 P 1. CHANGE 2' ISLAND FORM RADIUS TO 4" 6-19-87 CDE RW \ <br /> REVISED IMPACT VALVED TAIL 6-19-91 CPD 2. CHANCE ISLAND FORM DIMENSIONS & NOTES 10-21 8 CDE EMJ �T <br /> _ m cmi 6 SINGLE AND DUAL DISPENSERS 12. REVISIEO STANDARD ISLAND LAYO TS 7/22/91 P 3. ADD AIR UNE & SPEAKER CONDUIT 4-15-88 CDE <br /> 0 _ 13.ADDEO BREAKAWAY TO DISPENSER HOSES 9 5 91 CPO 4. REV. ISLAND LENGTH NOTE B-16-88 CDE <br /> 5, REV IMPACT VALUE MPD PLAN MAT'L SCHED, 3-8-89 CDE <br /> I - 4 DISPENSER TERMINAL STRIPS R L GATE 3 4 AI LN ON ISLAN LAY IIT 3_779TGPC ( � <br /> STANDARD ISLAND LAYOUTS -_ - 6REVISED ISLAND SIZES FOR HANDICAP R.B. REVISED PUMP MIT NTING DETAIL SIDEAAMPIO_18-9( GPD 14 <br /> 1 SCALE: 1/2• _ V-0• - 9. REV DIMENS. ON MOUNI"G. DETAIL SIDEIle <br /> 44t <br />
The URL can be used to link to this page