Laserfiche WebLink
TQ VENT RISERS NO. Q- EQUIPMENT DESCRIPTION SUPPLIED Q <br /> BY NOTES <br /> 28" DIA. MANWAY 8 2 2 1 DOUBLE WALL FIBERGLASS TANK OWNER 1) PEA GRAVEL BACKFILL, ALL OTHER MATERIAL MUST BE <br /> COVER O/C OR XERXES APPROVED BY TANK MANUFACTURER AND OWNER'S <br /> = r w 33 ROTATE SUBMERSIBLE PUMP AS - FIELD REPRESENTATIVE, <br /> g j w o ¢ 11 58 SHOWN TO PROVIDE CLEARANCE 2 42" DIA FIBERGLASS CONTAINMENT SUM OWNER 2) 2" RIGID STYROFOAM BOARD. <br /> wo 0 > w c� a r w a a 22" DIA. MANWAY FOR VENT/VALVE ASSEMBLY O/C OR XERXES <br /> Z ¢ � to O 3) FILTER FABRIC (TYPAR OR EQUIVALENT)- CUT TO FIT <br /> m - >v a z 3 31" DIA. FIBERGLASS SUMP RISER TIGHTLY AROUND PIPING PENETRATIONS. (BY CONTRACTOR) <br /> °- `Id � � Y w 00 o g O 4" SPARE OPENING O/C OR XERXES OWNER 4) FIBERGLASS PIPE AND FITTINGS TO BE A.O. SMITH OR <br /> z d a a K z IN TANK 31 - AMERON. FITTINGS MAY NOT BE MIXED. <br /> 'n w ¢ �. a z 13 4 32" DIA. FIBERGLASS RISER LID OWNER 5) SLIDE BACK EXCEPT TO TEST. <br /> > > '� ¢ 0/C OR XERXES <br /> / 6) SLOPE CONCRETE AROUND ALL MANHOLES 1" RISE <br /> PRODUCT CONNECTION \ \ 1 22 5 FIBERGLASS DISPENSER DRIP BOX <br /> NOT SHOWN FOR CLARITY O )- 7 OVER 12" RUN, <br /> 39 WESTERN FIBERGLASS OWNER WIRE MESH AND REINFORCING BARS TO BE A MAXIMUM <br /> - - 6 2" FIBERGLASS PIPE (FRP) CONTRACTOR <br /> OF 4" FROM TOP OF CONCRETE. <br /> O O 8) SLOPE TANKS 1/8" PER FOOT TOWARDS ANNULAR <br /> ® 7 2" DIA.x 45' FRP ELBOW CONTRACTOR SPACE MONITOR. <br /> ° 8 2" DIA.x 90' FRP ELBOW CONTRACTOR 9) SLOPE SIDES OF TANK HOLE OR USE SHORING FOR <br /> 34 \59 ° 29 - ALL TANK EXCAVATIONS IN ACCORDANCE WITH OSHA <br /> o \ 9 3"x 2" FRP TEE CONTRACTOR CONSTRUCTION INDUSTRY STANDARDS 29 CFR PART <br /> 00 \ 60 / 31 10 2" FRP ADAPTER- BELL x NPT MALE CONTRACTOR 1926 SUBPART P, OSHA STANDARDS-EXCAVATIONS; <br /> 2 / \\ FINAL RULE OCTOBER 1, 1989. <br /> 19 2P 11 2" FRP ADAPTER- SPIGOT x NET MALE CONTRACTOR 10) USE ANGLE FOR ASPHALT YARD ONLY, <br /> DOUBLE WALL FRP 61 - 11) REINFORCE CONCRETE SLAB AROUND MANHOLE WITH <br /> PRODUCT PIPING 12 3" FIBERGLASS PIPE (FRP) -CONTRACTOR 4-#4 REBAR 60" IN LENGTH. PLACE REBAR 6" FROM <br /> 3 <br /> SIDES OF BOX. <br /> 27 13 2"x 1 1/2"0FRP THREADED <br /> 34 REDUCER BUSHING CONTRACTOR 12) CONDUITS FOR WIRING OF SENSORS AND PROBES ARE <br /> TO BE SEPARATED FROM OTHER WIRING. WIRES MUST <br /> STAGE II VAPOR RECOVERY 12 22 2 14 3" DIA. FRP TEE CONTRACTOR BE SIZED ACCORDING TO MANUFACTURE'S SPECS. <br /> LINE FROM DISPENSERS 13) SEAL AND PLUG UNUSED OPENINGS. <br /> 15 3" DIA.x45' ELBOW CONTAINMENT FITTING CONTRACTOR <br /> TANK PLAN VIEW — "- -- 14) MINIMUM BEND RADIUS 8". <br /> CONTAINMENT SUMP PLAN DETAIL A 16 3DIA. TEE CONTAINMENT FITTING CONTRACTOR 15) INTERIOR OF FIBERGLASS DRIP BOX TO BE FILLED <br /> 3/87 = 1 '-0" 17 2" DIA. GALV. STEEL PIPE CONTRACTOR WITH PEA GRAVEL BACKFILL TO SHEAR VALVES. <br /> 16) 3/4" CONDUIT FOR ANNULAR SPACE MONITOR. <br /> 8" THICK CONCRETE SLAB 6 7 18 2" DIA.x 90' GALV. STEEL ELBOW CONTRACTOR <br /> 3'-0" REINF. W/6x6x6 6 WWF 45LOOP CONDUITS BETWEEN TANKS, THROUGH <br /> DIA.x ' GALV. STEEL ELBOW ONTRACTOR JUNCTION BOX. SEAL OFF HOME ;tUBOTH TANK <br /> (DO NOT USE FIBER IN CONCRETE) 19 2"_ _ _ _ AND BUILDING. DO NOT PIPE INTOWIRININ G TROUGH. <br /> 20 4" GALV. RISER- LENGTH AS REQUIRED CONTRACTOR 17) 3/4" CONDUIT FROM EACH SUBMERSIBLE PUMP TO <br /> 2'-0" A 8 C D E 6 35 21 4" PIPE CAP- SCH. 40 GALVANIZED CONTRACTOR BUILDING. TERMINATE WITH SEAL-OFF PER NFPA <br /> 1 2 1 2 2 2 2 2 2 2 11 -- - SPECIFICATIONS. <br /> 22 2"x 18" S.S. FLEX CONNECTOR- <br /> 18) 3/4" CONDUIT FOR ELECTRONIC TANK GAUGE. <br /> q D MALE SWIVEL x FEMALE OWNER LOOP CONDUITS BETWEEN TANKS, THROUGH <br /> 4. -4 z 'D ,D - TITEFLEX OR TELEFLEX JUNCTION BOX. SEAL OFF HOME RUN AT BOTH TANK <br /> • .. . . ;r:• ,�/ • . '. - 1;'. - - 25 D . T D CONNECTOR18 TITEFLEX "SOIILSAFE"XAPC OWNER <br /> z a s— 3 AND BUILDING DO NOT PIPE INTO WIRING TROUGH <br /> ` 4 <br /> PEA GRAVE6 o P� G 1 4 4 26 OR TELEFLEX "FLUIDFLEX' 19) 3/4" CONDUIT FOR CONTAINMENT SUMP SENSORS. <br /> F LOOP CONDUIT BETWEEN CONTAINMENT SUMPS, <br /> RAVEL 3 2 24 4" PVC RISER PIPE ONTRACTOR THROUGH JUNCTION BOX. SEAL OFF HOME RUN AT <br /> _ BOTH TANK AND BUILDING. DO NOT PIPE INTO WIRING <br /> m 1 I A 17 25 LEAK DETECTOR- RED JACKET, OWNER TROUGH, <br /> m w 1/2 52 18 30 2� PISTON OR DIAPHRAGM 2D) CONDUIT BETWEEN 4!' CONDUIT RSUMIPSBOTHROUGH JUNCTION BOX, <br /> ' z OP <br /> 26 1 1/2 F,P SUBMERSIBLE PUMP- WITH A SEAL OFF AT EACH ENTRY. DO NOT PIPE INTO <br /> 2 g 30 RED JACKET OWNER WIRING TROUGH. <br /> 22 31 21) PROVIDE 6" CLEARANCE BETWEEN MANHOLE LID AND <br /> 6 27 LIQUID SENSOR-- VEEDER ROOT TLS-350 OWNER <br /> III— -III = p 12 9 -- - - -- --- — TOP OF RISER FOR TANK GAUGE. <br /> _III III_- a 4 3„ 14 28 TANK GAUGE- VEEDER ROOT TLS-350 OWNER 22) ALL PENETRATIONS MUST BE PERPENDICULAR <br /> 4 11 19 29 JUNCTION BOX- CH GUP215 ONTRACTOR TO CONTAINMENT SUMPS AND DRIP BOXES. <br /> -III —III 30 SEAL OFF- CH EYD2 CONTRACTOR 23) SECURE SHEAR VALVE TO BRACE. <br /> 31 3/4" FLEXIBLE ENTRY BOOT- 24) VENT PIPING CONTAINMENT TO BE PROVIDED ONLY <br /> —III 24 2,V' =11 I n 7 ENVIRON FEB-3075 OWNER WHEN REQUIRED 8Y LOCAL CODE. <br /> MIN. ----- ---- 25) PROVIDE 6" CLEARANCE BETWEEN TOP OF TEST <br /> (MIN.) <br /> _III—III Z , 32 1" FLEXIBLE ENTRY BOOT- OWNER WELL CAP PLUG AND GRADE. <br /> 34 39 N ENVIRON FEB-3100 26) CUT AND POSITION FILL TUBE WITH ANGLE AWAY FROM II —III ISUBMERSIBLE PUMP. <br /> FLEXIBLE ENTRY BOOT- OWNER II ENVIRON FEB-6200 27) INSTALL TANK ID. MARKERS IN THE SPILL CONTAINMENT <br /> MANHOLES AROUND FILL RISERS. MANHOLE COVERS <br /> D 34 S FLEXIBLE ENTRY BOOT- OWNER SHALL BE PRIMED AND PAINTED ACCORDING TO THc <br /> _ 2 22" DIA. MANWAY ENVIRON FEB-6300 FOLLOWING SPECIFICATIONS: <br /> 12" MIN. 1 g g —III- 27 W/28" DIA. COVER 35 36" MANHOLE- POMECO 110-36Wi, REGULAR UNLEADED - WHITE w/BUCK CROSS <br /> CNI 236RSG OR EQUAL (WATER TIGHT) OWNER REGULAR LEADED - BLUE <br /> l II I = - I I I-III-III-III-III-III-III-III III-III-III-III- III-III-III-III-III-III-III-III -_-__ PLUS UNLEADED - BLUE W/WHITE CROSS <br /> — — — — =— —I —I —I TL—I —I —I I— CONTAINMENT SUMP ELEVATION DETAIL B 36 30" MANHOLE- POMECO 110-30 FILL SUPER UNLEADED - RED W/WHITE CROs <br /> —1 1-- = II—III—I 1=1 1=1 1=III=III-I T —" TANK ELEVATION _ <br /> OR CNI 23OR OWNER DIESEL - YELLOW <br /> 3/8" = 1 '-0" 1"= .KEROSENE - BROWN <br /> 37 SPILL CONTAINER- POMECO 211 , OWNER +HEATING OIL - GREEN <br /> DPW 1-4500 OR EBW 705-BG +USED OIL - BLACK <br /> +VAPOR RECOVERY - ORANGE <br /> 38 PUMP BOX- BEN DEL, FORMEX OR <br /> -OBSERVATION WELL - BLACK TRIANGLE ON WHITE BACKGROUND <br /> MORGAN OWNER SUBMERSIBLE PUMPS - GRAY <br /> LINE OBSERVATION TANK GAUGE - GRAY <br /> L 4 e WELL 39 VENT VALVE ASSY/FLOAT VENT VALVE .PAINT SURROUNDING 3" OF CONCRETE PAD TO MATCH. <br /> I - 10 DPW 233VM-6045/53VML-3120 OWNER <br /> z 2 2 WITH STEEL PIPE PLUG -- 28) PIPING SHALL BE LAID AND CONTINUOUSLY SUPPORTED <br /> iv iv 3" FRP VAPOR 40 4" FILL CAP- OPW 634-TT OR EQUIV. OWNER ON A 6' BEDDING OF CLEAN COMPACTED PEA GRAVEL. <br /> i l RETURN LINE 41 4"x4" ADAPTER- OPW 633T-8076 OWNER PL PIPING SHALL BE SUPPORTED BY BLOCKS, <br /> 8" THICK CONCRETE PAD PLANKS OR OTHER DEBRIS. <br /> 1 ( 1 2" FRP PRODUCT PIPING W/ 42 3" VAPOR CAP- OPW 1711 -T-3 OWNER 29) VENT LINE SHALL STAND NO LESS THAN 4' FROM <br /> If 3" FRP CONTAINMENT PIPING 43 3"x4" ADAPTER- OPW 1611 -AVB -- OWNER OUTSIDE EDGE OF CURB. <br /> 12 19 I I 44 2" VENT CAP- DPW 23 OR EQUAL OWNER 30) INTERIOR OF FIBERGLASS CONTAINMENT SUMP TO BE <br /> o o CLEAR OF PEA GRAVEL BACKFILL SO THREADED <br /> IIS'. 45 4" DIA. ALUMINUM DROP TUBE W/OPW OWNER JOINTS ARE EXPOSED. <br /> 61-SO OVERFILL PREVENTION VALVE _- 31) REAM ALL RISERS FOR FULL PIPE BORE. <br /> 1 46 SHEAR VALVE- DPW 10-RMP OWNER <br /> (FOR "MPD-3" USE OPW 10-RM) <br /> 12 1F 47 6" GALV. RISER (LOTH. AS REQ'D.) OWNER <br /> o Ilie <br /> o I I o Ill CONDUIT FOR DISPENSER A 48 3" TEST WELL PLUG- SHAW AERO CONTRACTOR TOSCO NORTHWEST COMPANY <br /> DRIP BOX SENSORS TO BLDG. 1d 49 TANK ID. MARKER- EW A 0022-1 -8 <br /> 8 OR UNIVERSAL #59 OWNER <br /> 1 2� �z� I.'.4 2 LINE OBSERVATION RETAIL MARKETING <br /> MINI MINI MINI MIN. WELL _ _ / \ _ _ / 50 1 1/2"x 1" GALV. STEEL REDUCER CONTRACTOR G <br /> F 51 FERNCO 1056-64 W/ STAINLESS STEEL DESIGN AND ENGINEERING <br /> I I 2 2 WORM CLAMP W/O AIR STEM OWNER 200 PUBLIC SQUARE <br /> ICLEVELAND, OHIO 44114 <br /> 52 FERNCO 1056-32 FLEXIBLE W/AIR STEM OWNER <br /> (D (D (D ( 1 53 FERNCO 1056-32 FLEXIBLE W/O STEM OWNER CALIFORNIA <br /> 54 1 1/27x 12" NON-METALLIC FLEX- <br /> TITEFLEX OR TELEFLEX OWNER _ DOUBLE WALL FIBERGLASS <br /> 0 1 1 o o TANK AND LINE DETAILS <br /> 12 i6 'O I O O I 155 18" MANHOLE- POMECO 110-18WT, <br /> — CNI 218R-12 OR EQUAL (WATER TIGHT) OWNER — <br /> LINES T O ERISERS NT 56 VEQEDERUID AROOTATLS- 350 ACE SENSOR- OWNER <br /> NOTE: ' _= m� I 57 1" GALV. STEEL PIPE NIPPLE CONTRACTOR <br /> 58 2" <br /> BOLD LINES DENOTE FRP PIPING ° x 12"--S.S. FLEX CONNECTOR- <br /> DWG. NO. : 15-CA 1 /2 REV. : ? <br /> N z DASHED LINES DENOTE CONDUIT I I MALE SWIVEL x FEMALE OWNER SCALE: 1"=1'-0" PLOT SIZE MADE BY: TAIT CF <br /> z MIN. 6 WIRES PER CONDUIT TITEFLEX OR TELEFLEX <br /> DATE: 4-26-91 CHECKED BY: <br /> 59 3" DIA. GALV. STEEL PIPE CONTRACTOR. <br /> REVISIONS �o DWN CKD <br /> R SES W-LUi� ].IO OI�tf_] YV�i SP.V£ ]-0 91-YI i <br /> m 60 3" STEEL PIPE UNION ONLRACTOR - — <br /> P TANK ELECTRICAL CONDUIT LAYOUT TYPICAL PIPING AND COND011 LAYOUT 61 3" FRP ADAPTER- BEL x NPT FEMALE .ONTRACTOR - <br /> 3/16" = 1'-0" NO SCALE 62 4" FACTORY SLOTTED PVC-1 PIPE, .02" ONTRACTOR <br /> SLOTS WITH CAP. <br /> y 15DWTCAI <br /> 1 <br />