My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2003 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4445
>
2300 - Underground Storage Tank Program
>
PR0231785
>
BILLING 2003 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 12:02:16 PM
Creation date
11/6/2018 10:18:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2003 - 2014
RECORD_ID
PR0231785
PE
2361
FACILITY_ID
FA0003994
FACILITY_NAME
PERSHING GAS FOR LESS
STREET_NUMBER
4445
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11018006
CURRENT_STATUS
01
SITE_LOCATION
4445 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PERSHING\4445\PR0231785\BILLING\BILLING 2003 - 2014 .PDF
QuestysFileName
BILLING 2003 - 2014
QuestysRecordDate
8/30/2016 9:49:09 PM
QuestysRecordID
3179084
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mass <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-PAGE 2 <br /> VI. DISPENSER MONITORING <br /> MONITORING OF AREAS BENEATH DISPENSERS)IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) Myo. <br /> Xr"ONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT(UDC) <br /> PANEL MANUFACTURERF M51 MODEL k: W2. <br /> LEAK SENSOR MANUFACTURER: M33_ MODEL q(S): Mse. <br /> WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? "yg&YES;9 b.NO Mss. <br /> WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? Via..YES ❑ b.NO 1456. <br /> WILL FAILUREIDISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? 4ff-&YES ❑ b.NO 1457. <br /> 2.MECHANICAL ASSEMBLY(e.g.,FLOAT AND CHAIN ASSEMBLY)IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK j <br /> ASSEMBLY MANUFACTURER: P7 rayo 14s8. MODEL#(S): F I oo`, rlkal m Mss. <br /> J&3.VISUAL MONITORING DONE: �.DAILY ❑. b.WEEKLY(Regvha..sa,cy.pp,ovd) MfiO, <br /> ❑ 4.NO DISPENSERS <br /> ❑ 99.OTHER(Specify) M61. <br /> VII. ENHANCED LEAK DETECTION <br /> ❑ 1.WE HAVE BEEN NO"I'IFIED BY THE STATE,WATER RESOURCES CON FROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK ^A'0. <br /> DETECTION(ELD)FOR"THE US'T(S)COVERED BY THIS PLAN.PER 23 CCR¢2644.1,ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br /> VIII. TRAINING <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) :neo. <br /> 1. �- THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> 2. OPERATING MANUALS.FOR ELECTRONIC MONITORING EQUIPMENT(Required) <br /> 3. THE FACILITY'S BEST MANAGEMENT PRACTICES(Required as of 1/01/2005) <br /> 4. CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br /> 5. CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> 6. STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> 7. ❑ SWRCB PUBLICATION:."WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br /> 99. ❑ OTHER(Specify): 1481. <br /> Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant in theirjob duties and can access those documents when needed. <br /> By January 1,2005 this facility will have a"Designated UST Operator"who has passed the operator exam administered by the International Code Council(ICC). By <br /> January 1,2005,and annually thereafter,the "Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems. <br /> This training will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> ➢ The facility employee's role with regard to the leak detection equipment. <br /> ➢ The facility employee's role with regard to spills and overfills. <br /> ➢ Whom W contact for emergencies and leak detection alarms. <br /> For facility employees hired on or after January 1,2005,the initial training will be conducted within 30 days of the date of hire. <br /> IX. COMMENTSIADDITIONAL INFORMATION <br /> Please use this section to include any additional UST system monitoring-related information(e g_,additional information required by your local agency): N185. <br /> _ X. PERSONNEL RESPONSIBILITIES <br /> AS OF 1/1/05, THE `DESIGNATED UST OPERATOR" IDEN-IIFIED IN SECTION III OF THE CURRENT UST OPERATING PERMIT APPLICATION- <br /> FAC'ILTTY FORM WILL HAVE ULTIMATE AUTIIORITY FOR PERFORMING THE MONITORING AC'I IVITIES AND MAIN FAIN ING LEAK DETECTION <br /> EQUIPMENT COVERED BY THIS PLAN,AND WILL PERFORM AND DOCUMENT MINIMUM MONTHLY VISUAL INSPECT IONS OF 9'HE FACILITY'S <br /> UST SYSTEMS IN ACCORDANCE WITI123 CCR$27 15(h) <br /> XI. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> OWNER/OPERATORS RE REPRESENTING iL <br /> n1si. <br /> er Msaa7 <br /> ❑Operator <br /> OWNE ERATOR NAME( riot): M92. OR TITLE: M1193 <br /> JA(Agency Use Only) This plan has been reviewed and: Approved ❑.Approved With Conditions ❑Disapproved <br /> Local Agency Signature: Date: e/ • <br /> Comments/Special Conditions: S' //(. <br /> Y <br /> 11 <br /> SJCEUD-d(07/03)(-314 V 07/23/03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.