Laserfiche WebLink
Page 3 of 5 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />PERSHING GAS <br />Facility Address: <br />I ; N PERSHIM_ SFOCKTON <br />Date: <br />UST System Observations <br />319 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />e V <br />e R COS <br />320 <br />HSC 25290.1(c3), <br />25290.2(c3) <br />Secondary containment not constructed to prevent water intrusion <br />❑ V <br />❑ R o COS <br />321 1 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />❑ V <br />❑ R o COS <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />❑ V <br />❑ R ❑ COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V <br />❑ R o COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V <br />❑ R ❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V <br />❑ R ❑ COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />❑ V <br />o R ❑ COS <br />327 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />❑ V <br />❑ R ❑ COS <br />328 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V <br />❑ R n COS <br />329 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V <br />❑ R ❑ COS <br />330 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V <br />o R u COS <br />331 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V <br />o R ❑ COS <br />332 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V <br />in R o COS <br />333 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V <br />❑ R ❑ COS <br />334 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />OV <br />c R o COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V <br />O R o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V <br />o R o COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />n V <br />❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />o V <br />❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />o V <br />o V <br />❑ R ❑ COS <br />❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />2060 <br />See below <br />Unlisted DesignIConstmction violation <br />V <br />e R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />105 <br />HSC 25286(c) Current BOE number not submitted. <br />UST Facility Operating Permit Application is lacking valid BOE Maintenance Fee Account Numbers. Immediately <br />log into CERS, update the required information, and submit for review by the EHD. <br />This is a minor violation. <br />Inspector: <br />FATINAH ZAREEF, REHS <br />one: <br />(209) 953-7311 <br />ate: <br />01/28/2016 <br />Page 3 of 5 <br />