COMPLIANCE INFO 2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO 2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 2:34:16 PM
Creation date
11/6/2018 12:48:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\R\ROTH\116\PR0523684\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
4/24/2018 11:35:23 PM
QuestysRecordID
3866361
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for Fast Lane Central Valley as of October 16, 2017. <br /> Open violations from June 17,2016 inspection <br /> Violation#316-Secondary containment not constructed to prevent water intrusion(after Jul 2003). <br /> Approximately one-quarter cup of water was found in the 91-product fill sump,approximately one-quarter inch of <br /> water was found on the south sloping side of the vent box on the automobile side of the facility and approximately <br /> one-half inch of water was found covering the vent box bottom on the truck side of the facility. Approximately one <br /> cup of liquid was found in the under dispenser containments(UDCs)for dispensers 13/14B, 16A/17B, 17A/1 813 and <br /> 18A/19. Secondary containment shall be constructed to prevent any liquid intrusion into the system by precipitation, <br /> infiltration,surface runoff or seepage.The service technicians removed the liquid during the inspection. Continue to <br /> check the 91-product sump,vent boxes and dispensers for liquid and if found,immediately contact a properly <br /> licensed,trained, and certified contractor to address the liquid intrusion into the 91-product sump, vent boxes and <br /> UDCs under permit and inspection of the Environmental Health Department(EHD). <br /> This was corrected on site. <br /> Violation#319-No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty. <br /> The 87-product spill container on the auto side and the north and south diesel spill containers on the truck side of <br /> the facility contained liquid. All USTs shall be equipped with a spill container that has a minimum capacity of five <br /> gallons and a drain valve that allows drainage of the collected spill into the primary container or provide a means to <br /> keep the container empty. The liquid was removed by the service technicians during the inspection. Continue to <br /> monitor for liquid in the spill containers and remove the liquid when present. <br /> This was corrected on site. <br /> Open violations from June 17,2016 inspection <br /> Violation#106-Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For T1,T2,T3,T4, and T5, beneath Pipe <br /> Monitoring is Performed Using the Following Methods, add"Yes"to Leak Alarm Triggers Automatic Pump <br /> Shutdown,and"Yes"for Failure/Disconnect Triggers Pump Shutdown. Also beneath Recordkeeping, change"No" <br /> to"Yes"for Equipment Maintenance and Calibration Records. The monitoring plan must be uploaded to the <br /> California Environmental Reporting System(CERS). Immediately log into CERS, make the necessary changes, <br /> and submit for review by the EHD. <br /> Open violations from July 16,2016 inspection <br /> Violation#316-Secondary containment not constructed to prevent water intrusion. <br /> Liquid was found in the truck side diesel vent sump,truck side diesel north and south turbine sumps.The gaskets <br /> from the sump lids/collars of the truck side diesel north and south turbine sumps are missing.These sumps are not <br /> liquid vapor tight. Secondary containment shall be constructed to prevent any water intrusion into the system by <br /> precipitation, infiltration, or surface runoff. Immediately remove this liquid, make a hazardous waste determination <br /> per Title 22 hazardous waste regulations, and manage accordingly. Immediately contact a properly licensed, <br /> trained,and certified contractor to address the water intrusion into the truck side diesel vent sump,truck side diesel <br /> north and south turbine sumps under permit and inspection of the EHD. <br /> Open violations from June 30,2016 inspection <br /> Violation#103-Current financial responsibility documents not submitted. <br /> Current financial responsibility documents have not been submitted to the EHD. Current financial responsibility <br /> documents are required to be submitted annually. Immediately log into the California Environmental Reporting <br /> System (CERS)at http://cers.calepa.ca.gov/,and upload the required documents. <br /> Page 7 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.