Laserfiche WebLink
Comments concerning testing completed on both the auto and truck sides on 8/8/2016: <br /> Auto testing: <br /> Page 2, the question was answered "no" for: Were all sensors visually inspected ,functionally tested, and confirmed <br /> operational? Please comment in Section E concerning this answer. <br /> Page 2, a number of questions were not answered in Section D. Answer all the questions and comment in Section E, if <br /> necessary. <br /> Page 2, Section E. lists the sensors that were tested on 6/16/16, not tested on 8/8/2016. It is noted that "Checked plug <br /> and drained brine from bottom of the sumps above to verify communications within the sump's secondary <br /> brine." Please clarify what sumps are referenced in this statement. <br /> Page 3, the box is checked for—Check this box if tank gauging is used only for inventory control. It is not appropriate to <br /> check this box.ATG is used for overfill protection. Please revise and complete the questions in Section F and add <br /> comments in Section H, if appropriate. <br /> Page 3, answer questions in Section G and comment in Section H, if appropriate. <br /> Truck testing: <br /> Page 2, a number of questions were not answered in Section D.Answer all the questions and comment in Section E, if <br /> necessary. <br /> Page 2,Section E. lists the sensors that were tested on 6/17/16, not tested on 8/8/2016. It is noted that"Checked plug <br /> and drained brine from bottom of the sumps above to verify communications within the sump's secondary <br /> brine." Please clarify what sumps are referenced in this statement. <br /> Page 3, the box is checked for—Check this box if tank gauging is used only for inventory control. It is not appropriate to <br /> check this box. ATG is used for overfill protection. Please revise and complete the questions in Section F and add <br /> comments in Section H, if appropriate. <br /> Add a comment that interstitial communication has not been tested and verified for vacuum sensor monitoring of the <br /> secondary containment piping on the truck side of the facility and the 87-, 91-, and diesel-product vent lines on the auto <br /> side of the facility. <br /> Please revise and resubmit the testing reports, and include the alarm history panel printout for each testing date. <br /> Thank you. <br /> Vicki McCartney, Senior REHS <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue <br /> Stockton, California 95205 <br /> Phone: (209) 468-9852 <br /> Email: vmccartney("7a.sjcehd.com <br /> f" <br /> r <br /> From: Michelle Mancera [mailto:AR@epiccompliance.com] <br /> Sent: Wednesday, November 2, 2016 8:16 AM <br /> To: Vicki McCartney [EH] <br /> Cc: Tanal Easma <br /> Subject: Fast Lane-Lathrop, 116 E Roth Rd_EHD <br /> 2 <br />