My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO 2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 2:34:16 PM
Creation date
11/6/2018 12:48:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\R\ROTH\116\PR0523684\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
4/24/2018 11:35:23 PM
QuestysRecordID
3866361
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Amok <br /> San Joaquin County hcn <br /> Environmental Health Department Ifibix <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 l q /$ / <br /> Telephone: (209)468-3420 Fax:(209) 468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility!Name: Facility Address: Date: <br /> Fast Lane Central Valley 1 116 Roth Rd, Lathrop August 08, 2016 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status _j V _j R ❑COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R n COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST c V n R n COS <br /> 326 HSC 25299(x)(9) Tampered with or disabled leak detection devices or alarms n V n R ©COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V o R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V o R o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements ❑V ❑R o COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system e V ❑R n COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(x)(3) Suction piping not properly sloped or incorrectly located check valve u V u R n COS <br /> 402 CCR 2643(4) Daily monitoring of suction pipe(pre-Jan 1984)not performed r V ❑R o COS <br /> 403 CCR 2643(4) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) u V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed (pre-January 1984) r V r R i COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation V �R u COS <br /> 2030 See below Unlisted Operations/Maintenance violation n V Ei R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V -i R D COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Iters#t Remarks <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> Vacuum sensor monitoring of the secondary containment piping of the truck side of the facility of the <br /> vacuum/pressure/hydrostatic(VPH) system has not been tested to date. The interstitial space of the underground <br /> storage tank shall be maintained, as designed, under constant vacuum such that a breach in the primary or <br /> secondary containment is detected before the hazardous substance is released into the environment. Immediately <br /> contact a properly licensed, trained, and certified contractor to test communication of the VPH components under <br /> inspection by the Environmental Health Department(EHD). <br /> This is a repeat violation, Class II. <br /> Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.