Laserfiche WebLink
Adak IdEb. <br /> IRW <br /> San Joaquin County 5 p �� z 74.5'' <br /> Environmental Health Department ,1 <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 $ �L <br /> Telephone: (209) 468-3420 Fax:(209)468-3433 Web:www.s ov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Fast Lane Central Valley 1 116 Roth Rd, Lathrop June 17, 2016 <br /> - SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. L11 sensor on the auto side <br /> went into alarm on 8122/2015, 9/9/2015 and 91102015, as noted by the designated operator (DO); however, the <br /> alarms were not addressed by the DO and maintenance records associated with these alarms were not found on <br /> site. L22 sensor, on the truck side, went into alarm on 1/27/2016 and went into alarm three times on 5/2012016 but <br /> the alarms were not documented by the DO nor were maintenance records associated with these alarms found on <br /> site. These records shall be maintained on site for at least three years. Monitoring records include: (1) date and <br /> time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any <br /> visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or <br /> other monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br /> reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br /> site and submit copies to the EHD. <br /> This is a minor violation. <br /> 203 CCR 2712(b) Failed to maintain records of monitoring, repair, lining, and upgrades on site. <br /> Monitoring system certification testing reports were not found on site during the inspection. Also records of repairs <br /> associated with the L11 sensor alarms on 812212015, 91912015, 9/10/2015 and L22 sensor alarms on 1/27/2016 and <br /> 5/20/2016 for the UST system were not found on site. These records shall be kept on site for the life of the tank. <br /> Immediately locate and maintain these records on site and submit copies to the EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans was not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class Il. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the January 29, 2016 <br /> and May 28, 2016 designated operator monthly inspection reports and failed to check that they were responded to <br /> appropriately. The missing alarms include: L22, brine sensor in dispenser 17A1180 on the truck side, on January <br /> 27, 2016 and three times on May 20, 2016. During the monthly inspection, the designated operator shall review the <br /> alarm history for the previous month, check that each alarm was documented and responded to appropriately, and <br /> attach a copy of the alarm history with documentation taken in response to any alarms to the monthly report. Ensure <br /> that designated operators performing monthly inspections at this facility are including all of the required information <br /> on the reports. <br /> This is a repeat violation, Class II. <br /> Page 5 of 8 <br />