Laserfiche WebLink
Aal Am, <br /> San Joaquin County <br /> Environmental Health Department ' <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sjciov.orglehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Fast Lane Central Valley 1 116 Roth Rd, Lathrop June 17, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004). <br /> The Diesel North and Diesel South submersible turbine pump (STP) sump 208 sensors on the truck side failed when <br /> tested. The continuous monitoring system shall be maintained to detect the entry of the liquid or vapor phase of the <br /> hazardous substance stored in the primary containment into the secondary containment and to detect water intrusion <br /> into the secondary containment. The 208 sensors were replaced and retested during the inspection. A"LIST Retrofit <br /> Verification with Inspector Already Onsite" form has been completed and provided to the operator and contractor. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 306 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> Communication in the 87-, 91-, and three diesel-submersible turbine pump (STP) sumps and fill sumps, and <br /> communication in the under-dispenser-containments (UDC) of the truck side of the facility as well as vacuum sensor <br /> monitoring of the secondary containment piping of the truck side of the facility of the vacuum/pressure/hydrostatic <br /> (VPH) system were not tested during the inspection on June 16 and 17, 2016. The interstitial space of the UST <br /> shall be maintained, as designed, under constant vacuum such that a breach in the primary or secondary <br /> containment is detected before the hazardous substance is released into the environment. Immediately contact a <br /> properly licensed, trained, and certified contractor to test communication of the VPH components listed above under <br /> inspection by the Environmental Health Department(EHD). <br /> Documentation of the S6 diesel STP sensor on the auto side of the facility indicates that the S6 sensor has been <br /> going into alarm intermittently. On 6/16/2016, S6 sensor was tested, passed, and closed alarm; however, S6 went into <br /> alarm on 6/17/2016. Immediately contact a properly licensed, trained, and certified contractor to repair or replace <br /> the sensor under permit and inspection by the EHD. <br /> This is a repeat violation, Class II. <br /> 316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> Approximately one-quarter cup of water was found in the 91-product fill sump, approximately one-quarter inch of <br /> water was found on the south sloping side of the vent box on the automobile side of the facility and approximately <br /> one-half inch of water was found covering the vent box bottom on the truck side of the facility. Approximately one <br /> cup of liquid was found in the under dispenser containments (UDCs)for dispensers 13114B, 16A/17B, 17A/1 8B and <br /> 18A/19. Secondary containment shall be constructed to prevent any liquid intrusion into the system by precipitation, <br /> infiltration, surface runoff or seepage. The service technicians removed the liquid during the inspection. Continue to <br /> check the 91-product sump, vent boxes and dispensers for liquid and if found, immediately contact a properly <br /> licensed, trained, and certified contractor to address the liquid intrusion into the 91-product sump, vent boxes and <br /> UDCs under permit and inspection of the Environmental Health Department(EHD). <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Page 6 of 8 <br />