Laserfiche WebLink
'ii 1II <br /> Appendix VI ( " <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION AUG 14 2017 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of � <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment, A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> ownerloperator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Fast Lane Central Valley Bldg.No.: <br /> Site Address: 116 East Roth Rd city; Lathrop, CA zip: 95330 <br /> Facility Contact Person: Hardeep Gill Contact Phone No.. 707-326-0369 <br /> MakelModel of Monitoring System: VR 350 Date of Testing/Servicing: 6/20/2017 <br /> B. Inventory of Equipment Tested/Certified Truck side <br /> Check the appropriate boxes to indicate specific equipment ins ectedlserviced: <br /> B <br /> T1 Diesel South Tank ID: <br /> nk Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> lar Space or Vault Sensor. Mode{: 303 ❑ Annular Space or Vault Sensor. Model: <br /> Sump/Trench Senscr(s). Model: 208 ❑ Piping Sump!Trench Sensor(s). Model:mp Sensor(s). Model 208 ❑ Fill Sump Sensor(s). Model: <br /> anical Line Leak Detector. Model 99LD2000 l Mechanical Line Leak Detector, Model: <br /> ronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> Overfill 1 High-Level Sensor. Model: ❑ Tank Overfill 1 High-Level Sensor. Model: <br /> s eci equipment a and model in Section E on Page 2). ❑ Other (sped equipment t e and model in Section E an Page 2). <br /> Tank ID: T2 Diesel North Tank ID: <br /> 1 In-Tank Gauging Probe. Model: MAG-7 - In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: 303 -1 Annular Space or Vault Sensor. Model: <br /> Piping Sump 1 Trench Sensor(s). Model: 208 Piping Sump 1 Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). MOdel: 208 Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model 99LD2000 I Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Lire Leak Detector. Model: <br /> Tank Overfill 1 High-Level Sensor. Model: I Tank Overfill 1 High-Level Sensor. Model: <br /> Other(specify e ui ment type and model in Section E on Page 2). 1 I Others eci equipment t e and model in Section E on Page 2). <br /> Dispenser ID: 13 Dispenser ID: 16 <br /> +I Dispenser Containment Sensor(s). Model: 203 = Dispenser Containment Sensor(s). Model 208 <br /> �I Shear Valve(s). _ Shear Valve(s). <br /> I Dispenser Containment Floats and Chains. Dis enser Containment Floats and Chain(s). <br /> Dispenser ID: 14 Dispenser 1D: 17 <br /> Dispenser Containment Sensor(s). Model: 2O8 Lr Dispenser Containment Sensor(s). Model: 208 til <br /> Shear Valve(s). Le Shear Valve(s). ft <br /> Dispenser Containment Flcat s and Chains. ❑ Dispenser Containment Floats and Chains. <br /> Dispenser ID: 15 Dispenser ID: 18 <br /> 1r Dispenser Containment Sensor(s). Model: 208 a Dispenser Containment Sensor(s). Model: 208 <br /> E� Shear Valve(s). ii Shear Valve(s). <br /> 7 Dispenser Containment Floats and Chain(s). Dispenser Containment Floats and Chains. <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tankard dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspectedlserviced in accordance with the manufacturers' Sd lyt`� <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct 9_ <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a it Ci <br /> copy of the report;(check all that apply): System set-up FI Alarm history report 1 ` <br /> Technician Name(print): Briar) Dunahay Signature: <br /> Certification No.: B42886 License.No.: 956593 <br /> Testing Company Name: EPIC Environmental Compliance Systems Inc. Phone No.: 888-700-EPIC <br /> Testing Company Address: 39120 Argonaut Way # 643, Fremont, CA 94538 Date of TestinglServicing: 6/20/2017 <br /> Monitoring System Certification Page 1 of 4 12107 <br /> 2/21/07 <br />