Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209) 468-3433 Web:www.s0aov.orglehd <br /> Underground Storage Tank Programs Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Fast Lane Central Valley 1 116 Roth Rd, Lathrop June 20, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS Il,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator(DO) failed to document all the auto-side alarms from the attached alarm histories on the <br /> 919116, 10131116, 2114117 and 5117117 designated operator monthly inspection reports and failed to check that they <br /> were responded to appropriately. The missing alarms include: <br /> L28:Disp 11-12 brine fuel alarm on 8119/16, 8120/16 and 8/21/16 on the 919116 DO auto-side report; <br /> 1-4:91 STP brine fuel alarm on 10/10/16 on the 10131/16 DO auto-side report; <br /> L9:91 fill sump fuel alarm on 1/7117; L7: 87 fill sump fuel alarm on 1/28117 and S6:Diesel Prod. Line Sensor Fault <br /> alarm on 2111117 on the 2/14/17 DO auto-side report; <br /> Ll l:diesel fill sump sensor out alarm on 5/1117 and 513/17 on the 5/17117 DO auto-side report. <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> The DO auto-side report for 11/27/16 did not have Item 8 completed on the form; the alarm histories for L20 through <br /> L23 were not found on the Veeder Root panel printout; Item 4: Each alarm for the previous month has been <br /> responded to appropriately was marked "NA"when it should have been marked "Yes".There was an alarm (S6: <br /> diesel prod line sensor fault alarm) on 11-5-16 that was documented but not addressed by the DO. <br /> The DO auto-side report for 12/31/16 did not have a date on the Veeder Root panel printout; and Item 4:" Each <br /> alarm for the previous month has been responded to appropriately."was marked "NA". It should have been marked <br /> "Yes" since there was an alarm that was addressed by the DO. <br /> The DO auto-side report for 117/16 did not have Item 8 completed on the form; and the Veeder Root panel printout <br /> did not include the alarm history for S6. <br /> The DO auto-side report for 4126/17 did not have Items 1 through 4 and Items 9 through 15 completed on the form <br /> and Item 6 was not completed correctly; and <br /> The DO auto-side report for 5/17/17 had a Veeder Root panel printout dated 5/18117 and the panel printout was <br /> missing the alarm histories for L25 through L28 and S5 through S7. <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the required <br /> information on the reports. <br /> This is a repeat violation, Class II. <br /> FA0015977 PRO523684 SC001 06/20/2017 <br /> EHD 23-01 Rev.09/22116 Page 8 of 11 Underground Storage Tank Program CIR <br />