My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO 2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 2:34:16 PM
Creation date
11/6/2018 12:48:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\R\ROTH\116\PR0523684\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
4/24/2018 11:35:23 PM
QuestysRecordID
3866361
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for Fast Lane Central Valley as of October 16, 2017. <br /> Open violations from June 20,2017 inspection <br /> Violation#201 -Failed to maintain alarm logs and/or records of follow up actions. <br /> Monitoring records for the last three years were not found on site. Monitoring system certification test reports for <br /> 2014,2015 and 2016 were not found at the facility during the inspection. These records shall be maintained on site <br /> for at least three years. Monitoring records include: (1)date and time of all monitoring or sampling; (2)monitoring <br /> equipment calibration and maintenance records;(3)results of any visual observations; (4)results of sample analysis <br /> performed a lab or in the field; (5)logs of all readings of gauges or other mondoring equipment, ground water <br /> elevations,or other test results; (6)results of inventory readings and reconciliations. Immediately locate and <br /> maintain all maintenance and monitoring records for the last three years on site and submit copies to the EHD. <br /> Violation#206-Failure to comply with UST operating permit conditions. . <br /> A copy of the UST operating permit was not found on site. A copy of the UST operating permit and all attachments <br /> and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on site. <br /> Violation#209-Designated operator did not inspect all required items and/or the inspection reports not <br /> completed. <br /> The designated operator(DO)failed to document all the auto-side alarms from the attached alarm histories on the <br /> 9/9/16, 10/31/16, 2/14/17 and 5/17/17 designated operator monthly inspection reports and failed to check that they <br /> were responded to appropriately. The missing alarms include: <br /> L28:Disp 11-12 brine fuel alarm on 8/19/16,8/20/16 and 8/21/16 on the 9/9/16 DO auto-side report; <br /> L4:91 STP brine fuel alarm on 10/10/16 on the 10/31/16 DO auto-side report; <br /> L9:91 fill sump fuel alarm on 1/7/17; L7: 87 fill sump fuel alarm on 1/28/17 and S6:Diesel Prod. Line Sensor Fault <br /> alarm on 2/11/17 on the 2/14/17 DO auto-side report; <br /> L11:diesel fill sump sensor out alarm on 5/1/17 and 5/3/17 on the 5/17/17 DO auto-side report. <br /> During the monthly inspection,the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> The DO auto-side report for 11/27/16 did not have Item 8 completed on the form;the alarm histories for L20 through <br /> L23 were not found on the Veeder Root panel printout; Item 4: Each alarm for the previous month has been <br /> responded to appropriately was marked"NA"when it should have been marked"Yes".There was an alarm(S6: <br /> diesel prod line sensor fault alarm)on 11-5-16 that was documented but not addressed by the DO. <br /> The DO auto-side report for 12/31/16 did not have a date on the Veeder Root panel printout;and Item 4:"Each <br /> alarm for the previous month has been responded to appropriately."was marked"NA". It should have been marked <br /> "Yes"since there was an alarm that was addressed by the DO. <br /> The DO auto-side report for 1/7/16 did not have Item 8 completed on the form;and the Veeder Root panel printout <br /> did not include the alarm history for S6. <br /> The DO auto-side report for 4/26/17 did not have Items 1 through 4 and Items 9 through 15 completed on the form <br /> and Item 6 was not completed correctly;and <br /> The DO auto-side report for 5/17/17 had a Veeder Root panel printout dated 5/18/17 and the panel printout was <br /> missing the alarm histories for L25 through L28 and S5 through ST <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the required <br /> information on the reports. <br /> Page 3 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.