Laserfiche WebLink
.jan 23 06 08: 13p M Dotten 2033-2650 p. 2 <br /> Pacility: Madsen Page 2 <br /> D. Results of Testing/Servicing: <br /> NIA Software Version Installed NONE <br /> 0 Yes ❑ No* 1s the audible alarm operational? ❑Deafening? Outside Alarm <br /> ®Yes ❑ No's Is the visual alarm operational? <br /> ❑Yes ❑ No* Is the 2rint function operational? ®Not installed. <br /> ®Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed o erational? <br /> 1E Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their Rroperoperation? <br /> ❑Yes (] No* if alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modern) <br /> Z N/A operational? <br /> ]Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> JR NJA monitoring system detects a leak,fails to operate,or is electrically disconnected? if yes;which sensors initiate <br /> positive shut-down? (Check all that apply) ❑ Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failureldisconnection? ❑Yes; ❑No. <br /> ❑Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e..no <br /> N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s and operating ro erl ? If so, at what percent of tank capacity does the alarm trigger? <br /> Yes* ® No Was any monitoring equipment replaced? if yes, identify specific sensors, probes, or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product; ❑Water. if yes,describe causes in Section.E,below. <br /> Yes ❑ No* Was m nitoring system set-up reviewed to ensure proper settings?Attach set up reports, if applicable <br /> ®Yes ❑ No* Is all monitoring equipment oerational er manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: No deficiencies. Fillspill containment tested and passed with Incon Sump Tester. <br />