My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1986 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1800
>
2200 - Hazardous Waste Program
>
PR0514003
>
COMPLIANCE INFO 1986 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2024 9:16:23 AM
Creation date
11/6/2018 8:37:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986 - 2016
RECORD_ID
PR0514003
PE
2227
FACILITY_ID
FA0003761
FACILITY_NAME
ST JOSEPHS HOSPITAL
STREET_NUMBER
1800
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12718044
CURRENT_STATUS
01
SITE_LOCATION
1800 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\C\CALIFORNIA\1800\PR0514003\COMPLIANCE INFO 1986 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.04 <br /> State of Califomia+lealth and Welfare Agency Department of Health Services <br /> Page 7 of 9 pages <br /> RADIOACTIVE MATERIAL LICENSE License Numb-: 1276-39 <br /> Supplementary Sheet Amendment Number:688 <br /> 36. Special Requirements for Remote Afterloading Device Calibration and Spot Checks. <br /> (a) At intervals not to exceed daily or prior to use(if used less fi-equently),the following tests shall <br /> be performed: <br /> (1) Source position indicator(s). <br /> (2) Source positioning reproducibility, to within± 1 mm <br /> (3) Inspection of guide tubes for kinks and other imperfections. <br /> (b) At intervals not to exceed monthly or prior to use (if used less frequently), the following tests <br /> shall be perforated: <br /> (1) Accuracy of the timing device. <br /> (2) Source travel time error. <br /> (c) At installation and intervals not to exceed three months, (one month for Ir-192) thereafter, the <br /> licensee shall determine the dose accuracy to within±5 percent. <br /> 37. No remote afterloading device equipment operation authorized by this license shall be initiated unless the <br /> licensee has in his possession detailed written instructions specific for the make and model of the remote <br /> afterloading device equipment and for the type of operation involved. <br /> 38. The licensee shall not transfer any radioactive source or device containing a radioactive source, except in <br /> accordance with the transferee's radioactive material license as to kind and amount of radioactive material, <br /> manufacturer and model number of the radioactive source,and manufacturer and model number of the remote <br /> afterloading device. <br /> 39. Each remote afterloading device shall be inspected and serviced in accordance with the manufacturer's <br /> recommendations. <br /> 40. Installation, relocation, maintenance, and repair of devices containing radioactive material, and leak testing, <br /> replacement and disposal of sealed sources containing radioactive material used in devices shall be perforated <br /> only by persons specifically authorized to do so. <br /> 41. Upon initial source loading and/or subsequent to each source exchange, radiation surveys shall be performed <br /> prior to initial human use as follows: <br /> (a) A radiation survey shall be made of: <br /> (1) The unit source housing, with the source(s) in the shielded position. The maximum radiation <br /> levels at 20 centimeters from the surface of the source housing not exceed 3 milliroentgens per <br /> hour. <br />
The URL can be used to link to this page
Your browser does not support the video tag.