Laserfiche WebLink
N0. Q — EQUIPMENT DESCRIPTION SUPgPY IED Q — NOTES <br /> ISLAND MULTI-PRODUCT DISPENSER STAGE I RISER 1 3" FIBERGLASS PIPE (FRP) <br /> A.O. SMITH RED THREAD II OR CONTRACTOR 1. MAIN VAPOR RETURN LINE IS 3" DIAMETER FRP. <br /> FILL RISER AMERON DUALLOY 3000 USE 2" DIAMETER FRP PIPE BETWEEN MAIN RETURN <br /> FRP PRODUCT LINES 7' FRP VAPOR 2" FRP VAPOR 2 2" FIBERGLASS PIPE (FRP) LINE AND DISPENSER. <br /> RETURN LATERAL RETURN LATERAL A.O. SMITH RED THREAD II OR CONTRACTOR 2. SLOPE_ VAPOR RETURN LINE NOT LESS THAN 1/8" <br /> SEE STAGE II AMERON DUALlOY 3000 PER FOOT AND NOT MORE THAN 1/4" PER FOOT <br /> PIPING ISOMETRIC 3 8 FT, LONG DISPENSER HOSE- FROM DISPENSERS TO TANKS. NO AIR OR LIQUID <br /> REINFOkCFD CONCRETE DAYCO PET0 ROFLEX 200OWNER TRAPS ARE ACCEPTABLE. <br /> PEA GRAVEL OR ASPHALT PAVEMENT 3" FRP MAIN VAPOR 4 STAGE II VAPOR RECOVERY NOZZLE- <br /> BACKFILL TANK PAD RETURN LINE FROM EMCO WHEATON A-4001 (MPD-3 ONLY) OWNER 3. FIBERGLASS PIPE AND FITTINGS TO BE A.O. SMITH <br /> NEW OR EXISTING MPD INSTALLATION �SDISPENSERS 5 HOSE RETRACTOR ASSEMBLY OWNER OR AMERON. FITTINGS MAY NOT BE MIXED. <br /> POMECO HIMAST 73" <br /> MAIN VAPOR RETURN CINEOL VEN1 RISERS 6 GASOLINE CONNECTION HOSE CONTRACTOR 4. STEEL FITTINGSSTEEL PIPEALL SHALLL BEHCLASS EDULE 150E USE NGASOILA <br /> / - / z '(0 7 HOSE CLAMP - DAYCO OWNER SOFT SET FOR PIPE JOINT SEAL. <br /> \�\ PRODUCT 1 \� 8 BREAKAWAY COUPLING- <br /> /� 3" FRP VAPOR EMCO WHEATON COAXIAL "SAFEBREAK' CONTRACTOR 5. VAPOR RECOVERY PIPING SHALL BE LAID AND <br /> �\\� w LINES 2 �/ b RETURN LINE MODEL #A4019-002 CONTINUOUSLY SUPPORTED ON A 6" BEDDING OF <br /> / 9 1" STEEL PIPE NIPPLE PEA GRAVEL. TRENCHES SHALL BE BACKFILLED <br /> X `D \� SCHEDULE 40 GALVANIZED CONTRACTOR COMPLETELY TO THE UNDERSIDE OF PAVING WITH <br /> FRP oa 10 1 11Z' STEEL UNION CONTRACTOR PA GRAVEL. <br /> \� \ VENT LINE at u' 11 1" STEEL UNION CONTRACTOR NO PIPING SHALL BE SUPPORTED BY BLOCKS, <br /> °Mu" t2 1 t/2" x 3/4" GALVANIZED PLANKS OR OTHER DEBRIS. <br /> 2" FRP VAPOR EXTRACTOR aarFT°EP REDIUCER NPT FEMALE X NPT MALE CONTRACTOR <br /> RETURN LATERAL FITTING sups" 13 3/4"' STEEL 90' ELBOW CONTRACTOR 6. CONNECT UNDERGROUND STAGE II PIPING TO MPD <br /> DISPENSER PIPING DURING CONSTRUCTION FOR <br /> 3" OR u" � 14 3/4" STEEL PIPE NIPPLE CONTRACTOR BOTH IMMEDIATE AND FUTURE USE. <br /> N LINE <br /> y g' g" g" y' 15 3/47'STAG STEEL UNION CONTRACTOR 7 FOR SINGLE AND DUAL DISPENSERS, STUB UP THE <br /> SUEMERGED PUMP <br /> COP;TAINMENT SUMP SINGLE OR DUAL 16 STAGE II VAPOR RECOVERY NOZZLE- OWNER PIPING AND CAP OFF WHEN PIPING WILL NOT BE <br /> 38" ) EMCO WHEATON A-4005 (ADVANTAGE ONLY) <br /> DISPENSER (TAWS A{tei EytIS71NG USED IMMEDIATELY. <br /> 17SPACER HOSE— OWNER <br /> 2" FRP VENT LINES DAYCO PETROFLEX 2000 MODEL 7574 <br /> 8. SAFETY BREAKS ARE TO BE INSTALLED. <br /> TO VENT RISERS LAND 18 PUMP HOLD DOWN BOX- BENDEL, FORMEX <br /> OWNER <br /> PIPING TRENCH DETAIL 5 (mm$TIN Cy) OR EXISTING SINGLE & DUAL INSTAILA _ STAGE II PIPING ISOMETRIC OR MORGAN 9. TESTING PROCEDURE <br /> FRP PRODUCT LINES NO SCALE <br /> 1" = i'-0" 19 1 DISPENSER DRIP BOX-WESTERN FIBERGLASS OWNER AIR PRESSURE TEST THE STAGE Q VAPOR RETURN <br /> LINE FOR ONE HOUR AT 50 PSI. BRUSH A SOAP <br /> STAGE II PIPING PLAN 2 3 4 NOTE: AND WATER SOLUTION ON EVERY FITTING AND <br /> NO SCALE REFER TO DRAWINGS 15-CA 1/2 AND 2/2 FOR INSPECT FOR AIR BUBBLES, <br /> EQUIPMENT DESCRIPTION NOT SHOWN THIS SHEET. <br /> AFTER BACKFILLING THE TRENCHES, BUT BEFORE <br /> PAVING AND SETTING THE DISPENSERS, PERFORM <br /> 5 THE "PRESSURE DROP DURING FLOW TEST" AND <br /> THE "BLOCKAGE TEST' ACCORDING TO THE <br /> 17 17 7 REQUIRED LOCAL PROCEDURES. <br /> B / g RECORD BACK PRESSURES MEASURED DURING BOTH <br /> TESTS WITH FLOW RATES OF 60 CFH AND 100 CFH <br /> / 8 ON THE DATA SHEETS PROVIDED. <br /> 3 0 \ o oBACK PRESSURE MAY NOT EXCEED 0.45 INCHES OF <br /> 0 o 3 WATER AT A FLOW OF 60 CFH OR 0.95 INCHES <br /> an rand rand <br /> r= o o ® '°" OF WATER ATA FLOW OF 100 CFH. IF LIQUID <br /> Brand ran ran1:91BLOCKAGE IS INDICATED, MAKE NECESSARY REPAIRS <br /> 4 16 4 OR ADJUSTMENTS TO ELIMINATE THE BLOCKAGE, <br /> REPEAT THE "PRESSURE DROP DURING FLOW TEST' <br /> AND THE "BLOCKAGE TEST" AFTER COMPLETION OF <br /> b � THE PARD WORK AND INSTALLATION OF DISPENSERS. <br /> SUBMIT COMPLETED TEST DATA SHEETS TO THE <br /> FIELD ENGINEER FOR APPROVAL. <br /> 'n 10. STAGE II FLEXIBLE CONNECTOR TO BE CONTAINED <br /> WITHIN DISPENSER DRIP BOX, FOR SITES WITH NO <br /> CONTAINMENT BOX, THE FLEXIBLE CONNECTOR MUST <br /> BE ISOLATED USING AN ISOLATION SLEEVE. <br /> b <br /> ELEVATION ELEVATION ELEVATION 7 B <br /> GILBARCO MPD-3 B GILBARCO ADVANTAGE MPDA8 SINGLE DUAL DI, NSERS <br /> 3" FRP VAPOR 3" FRP VAPOR RETURN LINE <br /> RETURN LINE ISLAND & DISPENSER <br /> IS & DISPENSER rc <br /> w !SV & DISPENSER <br /> z z <br /> z w <br /> vwa a <br /> o gir 2" FRP VAPOR a 2" FRP VAPOR " :1 SIDE Ln 3" FRP VAPOR b <br /> 3 4" CONDUIT RETURN LATERAL ,� RETURN LATERAL RETURN LINE 17 �w <br /> oFOR SPEAKER 3 b 7 3 g' PRODUCT LINES <br /> z �� 0 2" FRP VAPOR 0 oW <br /> z RETURIN LATERAL o z <br /> N PRODUCT LINES m 18 N 18 g N <br /> h �o <br /> (1) i" CONDUIT e - <br /> FOR DISPENSER <br /> 12 F <br /> (i) i" GOND' i 1 16" 3/4" CONDUIT -� 2 1 2" 11 3 4 5 fl/ 14" (1)-1" CONDUIT <br /> FOR SPEAKER <br /> FOR DISPEP "A" SIDE "A" SIDE <br /> (J BOX SIDE) (J BOX SIDE) <br /> PIPING PLAN PIPING PLAN ING PL <br /> GILBARCO MPD-3 GILBARCO ADVANTAGE MPD SINGLE DUAL DI ENSERS <br /> 1/2"=1'-O" 1/2"=l '-O" 1/2"=1'-D" <br /> Yj 42' + Y.+. 42 T� 7" 7' y' TOSCO NORTHWEST COMPANY <br /> 9 15/16" , 11 718" 11 7 8" 8 5/16_ AGE II PIPING STAGE II PIPING 5" 13 11Z' 18 1/Z 5" PIPING UNIONS 15 13 RETAIL MARKETING <br /> PIPING NS ECTION KIT CONNECTION KIT Sn <br /> BY GI' CO A s�x b b. BARCO BY GILBARCO j_epz BY GILBARCO J-BOX DESIGN AND ENGINEERING <br /> Ni- <br /> 14 <br /> FOR 1- CNDUIT DISPENSER 15 CALIFORNIA <br /> SAWCUT 4 1/4 2 STAGE II VAPOR RECOVERY <br /> 19 (1)-1" CONDUIT DIA. HOLE FOR 19 18 SAWCUT 4 1/4" 14 .� <br /> ENVIRON FLEXIBL .� DIA. HOLE FOR (7ILBARCO DISPENSERS <br /> FOR DISPENSER ENTRY BOOT (TYP <br /> ENVIRON FLEXIBLE <br /> ENTRY BOOT (TYP.) 7" <br /> a N <br /> DWG. NO.: 15R-S2VR-CA 2/2 REV.: <br /> 1O b o b SCALE: 1 2°=1'-0" PLOT MADE BY: TAIT CF <br /> 0 <br /> . z DATE: 4-25-91 CHECKED BY: _ <br /> REVISIONS DATE OWNI CKD <br /> 13" 8" 8" 8" 5" T 6" 8" 8" 13" <br /> STAGE II PIPING CONNECTION STAGE II PIPING CONNECTION STAGE II PIPING CONNECTION -- <br /> GILBARCO MPD-3 Q GILBARCO ADVANTAGE MPD A i SINGLE & DUAL DISPENSERS <br /> 15S2VRCA <br />