My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL FILL SUMP AND UDC INSTALL PLAN 2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3725
>
2300 - Underground Storage Tank Program
>
PR0231417
>
INSTALL FILL SUMP AND UDC INSTALL PLAN 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:04 PM
Creation date
11/6/2018 10:37:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
FILL SUMP AND UDC INSTALL PLAN 2003
RECORD_ID
PR0231417
PE
2361
FACILITY_ID
FA0003780
FACILITY_NAME
TRACY SHELL*
STREET_NUMBER
3725
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21217030
CURRENT_STATUS
01
SITE_LOCATION
3725 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TRACY\3725\PR0231417\INSTALL\FILL SUMP AND UDC INSTALL PLAN 2003.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br /> _-_ — - --- — -- - - -- ELECTRONIC MONITORING SYSTEMS (PER "APPROVED MATERIALS LIST") PROVIDES <br /> ADVANCED AUTOMATIC CONTROL OF UNDERGROUND TANK AND PIPING INSTALLATIONS. <br /> EXPLOSION PROOF " USE SENSOR DETAIL FOR TURBINE AND FILL SUMP EACH MONITORING SYSTEM CAN BE CONFIGURED TO PROVIDE SIMULTANEOUS REAL <br /> JUNCTION BOX TIME SURVEILLANCE OF SEVERAL DIFFERENT INSTALLATION PARAMETERS WITH <br /> rDACB AUTOMATIC ALARM NOTIFICATION AND AUTOMATIC SHUTDOWN OF SELECTED COMPONENTS <br /> LE IN THE ADVENT OF DEVIATIONS FROM INTENDED OPERATIONS. SENSOR DESCRIPTIONS <br /> [NONCORROSIVE <br /> F�SEE <br /> NT SENSOR CABLE AND CLASSIFICATIONS ARE NOTED BELOW. <br /> E CABLE GRIP <br /> S1 CONTINUOUS MONITORING OF PRESSURIZED PRODUCT PIPING TO TEST, ALARM, <br /> RISER <br /> PIPE AND SHUT DOWN TURBINE IF LEAK OCCURS. SENSOR IS MANDATORY. <br /> = <br /> CAP S2 CONTINUOUS MONITORING OF SECONDARY CONTAINMENT PIPING AND TURBINE <br /> SENSORSUMP FOR INTRUSION OF ANY LIQUID. SENSOR IS TO BE INSTALLED SUCH <br /> MFGIR THAT ANY ALARM WILL SHUT DOWN TURBINE IF FUEL IS DETECTED. SENSOR <br /> _ IS MANDATORY. <br /> I I �� 53 CONTINUOUS SIMULTANEOUS MONITORING OF TANK INNER AND OUTER WALLS <br /> L <br /> BY HYDROSTATIC MEANS. IF INTERSTITIAL LIQUID (WATER OR SALT BRINE) <br /> PIPE SEAL OFF I / \ LEVEL GOES UP OR DOWN BEYOND LIMITS, SENSOR WILL ALARM BUT SHUT <br /> � RISER <br /> FITTING <br /> r � / NOTHING DOWN AS SUCH ACTION WILL NOT ARREST THE PROBLEM. HOWEVER, ' <br /> f \ INTERSTITIAL LIQUID WILL NOT PERMIT PRODUCT TO ESCAPE DUE TO HIGHER <br /> IL � LIQUID DENSITY AND HIGHER HYDROSTATIC HEAD REGARDLESS OF INVENTORY <br /> a„o <br /> / \ LEVEL. SENSOR IS MANDATORY FOR SUCH TANKS. <br /> INTERNALLY S4 CONTINUOUS MONITORING OF TANK RISER INTERSTII, IF RISERS ARE CONTAINED. <br /> INTRINSICALL THREADED SENSOR WILL AUTOMATICALLY ALARM IF ANY LIQUID INTRUDES INTO INTERSTII, <br /> SAFE SENSOR I <br /> ADJUSTABLE CONDUIT TO LEAK DETECTION PANEL IN BLDG. JL 3/8” x 3" CLEVIS ; BUT WILL SHUT NOTHING DOWN AS SUCH WILL NOT ARREST THE PROBLEM. <br /> LEAD CABLE <br /> S3 W/COTTER PIN I TANK SENSOR IS OPTIONAL. HOWEVER, IF RISERS ARE CONTAINED, SENSOR CONDUITS <br /> C MUST ALSO BE INSTALLED FOR POSSIBLE FUTURE USE. SINCE CONDUITS ARE <br /> NOTE: I PART OF SAID CONTAINMENT, SAID CONDUITS MUST PASS BOTH N.E.C. CONTINUITY <br /> INSTALL 1/4 POLYFLOW TUBE TO GRADE TEST AND PRESSURIZED LEAK TEST. <br /> IF GROUND WATER MAY EXCEED RISER HEIGHT 2"0 FIBERGLASS SLEAVE <br /> (SMITH OR AMERON PIPE) I CONTAINMENT SUMP IF THESE RISERS ARE CONTAINED IN A SUMP, SUBSTITUTE AN S2 TYPE <br /> PERFORATED or SLOTTED SENSOR AND WIRE IT TO ALARM, THIS WILL SHUT DOWN NOTHING. <br /> ENTIRE LENGTH OF SLEEVE. <br /> TO BE ATTACHED TO SIDE OF fI / S5 CONTINUOUS PRODUCT INVENTORY LEVEL MONITORING. CAN BE PROGRAMMED <br /> RISER PIPE CAP JUNCTION SUMP USING METHACRYLATE ADHESIVE. I S2 EXPLOSION—PROOF JUNCTION BOX TO PROVIDE LOW INVENTORY LEVEL WARNING, HIGH INVENTORY LEVEL ALARM, <br /> AND FITTINGS Box SUMP WALL�\ WATER WARNING, AND AUTOMATIC TANK LEAK TEST TO .01 GPH ACCURACY PER <br /> 2TO BLDG IINSTALLEDUSEPA SENSOR OPTIONAL <br /> UCONTINUITYIFOR SENSOR <br /> MUST <br /> PVC BE AND MUST PSS BOTH AN NEC. TEST AND A <br /> PIPE RISER \ PRESSURIZED LEAK TEST. <br /> I <br /> INTRINSICALLY <br /> SAFE SENSOR SENSOR AND 2"0 PERFORATED <br /> FIBERGLASS SLEAVE TO BE PLACED S6 CONTINUOUS MONITORING OF DISPENSER SECONDARY CONTAINMENT SPACE FOR <br /> ON SIDE OF SUMP THAT PRODUCT INTRUSION BY ANY LIQUID, SENSOR WILL AUTOMATICALLY ALARM AND SHUT DOWN <br /> SENSOR TO BE 1/2" (MAXIMUM) PIPING PENETRATES SUMP. OFFENDING DISPENSER (NO ELECTRICAL POWER TO SAID DISPENSER) SHOULD <br /> _FROM LOWEST SPOT IN SUMP WASS. SENSOR TO BE PLACED ANY FUEL BE DETECTED. SENSOR IS MANDATORY. <br /> RISER PIPE 1/2" (MAX) FROM LOWEST POINT <br /> RESERVOIR IN SUMP. w ADDITIONAL SENSORS CAN BE UTILIZED, BUT MUST FIRST BE APPROVED BY <br /> FRP RESERVOIR SENSOR A A <br /> 53 SECTION A—A HEAD OFFICE MARKETING ENGINEERING STAFF UNLESS GENERAL SPECIFICATIONS <br /> LIQUID MONITORING FLUID OR "APPROVED MATERIALS LIST" IS REVISED TO SHOW APPROVALS OF SAME IN <br /> THE FUTURE. <br /> NOTE FOR ELECTRICIANS: ALL SENSITIVE CIRCUITS (SENSORS, DATA, ETC) <br /> SHALL BE ROUTED IN METALLIC CONDUIT AROUND (NOT THROUGH) WIRE <br /> DOUBLE WALL FIBERGLASS TANK TROUGH IN BUILDINGS, FAILURE TO COMPLY MAY CAUSE SYSTEMS TO PICK UP <br /> INDUCTIVE NOISE THAT DISRUPTS INTENDED OPERATION OF SENSITIVE DEVICES. <br /> S3 <br /> ' SEE E0103720 j <br /> 12" UNIVERSAL q62 8" CGNC NON—MANDATORY <br /> III_ —_)I ncHTI ACCESS 13K. SLAB. OBSERVATION WELLS <br /> —�� PVC RISER PIPE SEE I S1 I ' l <br /> -III— E01031200 I " r '•' r',,, AT LEAST ONE WELL IN <br /> UNPERFORATED TANK HOLE AREA TO BE <br /> CASING 24" 8" CASING CONFIGURATION <br /> DEEP. iMOU2 AS SHOWN BELOW. <br /> f� <br /> I I S2 12" NITRILE KEY CK <br /> S37�� II �EAGRAVEL FIL—SEAL—PAK JOINT (TYP) <br /> I <br /> BACKFILL XLINER WITH <br /> I ✓ STAINLESS SOME STATES HAVE PERMIT REQUIREMENTS FOR WELLS. IT WILL BE THE <br /> I BAND CLAMPS. I INSTALLING CONTRACTOR'S RESPONSIBILITY TO KNOW SAID CODE <br /> I I I REQUIREMENTS AND TO OBTAIN REQUISITE PERMITS. PRIOR HEAD OFFICE <br /> 4" SC CAS 40 PVC TANKS DEVIATIONS FROM ABOVE. IF LOCAL CODES DO NOT REQUIRE WELLS BUT DO <br /> II COMPANY ENGINEERING APPROVAL IS REQUIRED FOR ANY SIGNIFICANT <br /> Il fl II BOTTOM CA TANK WELL CASING WITH <br /> HOLE EXCAVATION. CONTINUOUS .020' UREQUIRE REGULAR MONITORING IF INSTALLED, 00 NOT INSTALL UNNECESSARY <br /> �I THREADED CONNECTIONS.CHINED SLOTS OBSERVATION WELLS. <br /> (NO GLUED JOINTS) LOCAL JURISDICTIONS MAY HAVE THEIR OWN REQUIREMENTS. IF THIS IS THE <br /> CASE, CONTACT THE LOCAL ALLIANCE COMPANY ENVIRONMENTAL ENGINEER. <br /> LI II s . 4 / <br /> 12" MIN. WELL / <br /> �-III-III- i��//� (TYP) TYPICAL/ <br /> TYPICAL DOUBLEWALL FIBERGLASS TANK_ ��j� <br /> LJ TANK SLAB <br /> / I <br /> THREADED PVC CAP <br /> OR FERNCO QUIK—CAP. <br /> REFERENCE DRAWINGS - E01031500; E01032700 <br /> These drawings and specifications are the confidential and ® APPROVALS <br /> v,m.,�mAq <br /> proprietary property of Shell Oil Products US and shall not be 4 10/31/02 ADDED SLEEVE NOTES jjR Shell Cil Products US 0 0 0 CALIFORNIA U.S.T. STANDARDS <br /> copied, reproduced, disclosed, or used without Shell Oil DISTRICT MANAGER <br /> Products US written authorization. They ore intended as 3 04/12/02 ADD NEW DETAILS (2) ADRY <br /> contract documents for use on this specific project In AREA TECHNICAL MANAGER❑ D 0 U B LEWALL TAN K/ PIPING <br /> conjunction with its issue date and are not suitable for use on 2 02/14/02 ADD NON—MANDATORY OBSERVATION WELL ADRY Motiva Enterprises LLMC <br /> a different project or ata later date. _____ DIAGRAM FROM "DELETED DWG. E01031800' --- <br /> --- TERMINAL MANAGER GRAPHIC SCALE ELECTRONIC MONITORING DETAILS <br /> I. <br /> 1 2/11 /02 CLARIFICATION / CHANGES ADRY 12700 Northborough Drive SCALE: SAP/WIC # DATE: DRAWN: REQUESTED BY: <br /> �C Shell Oil Products US. All Rights Reserved 2002 REV DATE DESCRIPTION OF REVISION BY APP HOUston TX 77067-2508 ENGINEER <br /> NONE 800062 03 MAY 2002 RABAGO HOVLAND E01031400 <br />
The URL can be used to link to this page
Your browser does not support the video tag.