GUIDELINES FOR TLS - 350R SYSTEM SET-UP (Revised 06/01 <br /> ** ONLY AUTHORIZED VEEDER-ROOT DISTRIBUTORS MAY PERFORM SYSTEM SETUP ** <br /> OUTPUT RELAY SETUP TABLE C <br /> Relay Type....... ........,...Standard Overfill High Level <br /> SYSTEM SETUP <br /> Relay Orientation...........Normally Closed aminal Low Delivery Limit Limit ! Label uLim Limit <br /> Asst nment Method. ....ln Tank Alarms...All tanks...Ove fill capacity Product Limit q, of `o of a Volume <br /> Assignment (Gallons) Limit (Gallons) Manufacturer Manufacturer <br /> Station Header.....................Must include address, city, and state along with 6-digit SAP site number. Actual Actual Actual Co Capacity <br /> Shift Start Times..._.............Time 1 : 6:OOAM Shift Times 2, 3 & 4 will not be used. OUTPUT RELAY SETUP Facilities without PLLDs Reference Table A (Gallons) Tank Tank p y Actual Capacity <br /> ( ) � ) - (Gallons) <br /> RORO locations may choose optional times to suit business needs. Capacity Capacity (Gallons) <br /> y p Relay Type.._...............Standard <br /> Periodic Test Warnings.......,Enabled (Days = 21) Relay Orientation..........Normally Closed 4000 150 700 95 98 XX = gallons XX = gallons <br /> Periodic Test Alarms............(Days = 28) Assignment Method......In Tank Alarm...Each Tank...High Water, Low Fuel (Per Tank Model Chart) (Per Tank Model Chart) <br /> Annual Test Warnings._......Disabled Assignment Method......Liquid Sensor Alarms...by Sensor; Fuel, High Liquid, Low Liquid XX - gallons XX = gallons <br /> System Security Code..........6-digit SAP location number Assignment Method......3 Wire CL Alarms...by Sensor.....Fuel, High Liquid 6000 250 1 000 95 98 (Per Tank Model Chart) (Per Tank Model Chart) <br /> (NOTE: System Key Pad Security Switch Must be Enabled: S2 position #1 Closed) PLLD LINE DISABLE SETUP (Facilities with PLLDs) Reference Table A 8000r400 <br /> 1500 95 98 XX = gallons XX = gallons <br /> COMMUNICATIONS SETUP DATA FOR THE POLECAT RS232 COMM BOARD - (HUGHES) -- (Per Tank Model Chart) (Per Tank Model Chart) <br /> Baud Rate = 9600 Assignment Method......In Tank Alarm...Each Tank...High Water, Low Fuel XX = gallons XX = gallons <br /> = ODD RS232 Security code must left disabled! Assignment Method......Liquid Sensor Alarms...by Sensor; Fuel, High Liquid, Low Liquid 100001500 95 98 (Per Tank Model Chart) (Per Tank Model Chart) <br /> Parity y _ allons Stop Bit = 1 (Per Tank Model Chart) (Per Tank Model Chart) <br /> 120001500 95 98Data Length = 7 TABLE ACOMMUNICATIONS SETUP DATA FOR THE RUBY RS232 COMM BOARD Rellt� Output Assignments far Alarm Activation and Shutdown50002000 95 98 (p r Tank llModel Chart) (Pe Tank IlModel Chart) <br /> Baud Rate = 9600 Ilons <br /> 200002500 95 98 Per Tank Model Chart Per Tank Model Chart <br /> Parity = NONE ( ) ( ) <br /> Stop Bit = 1 TANKS PIPING CONTAINMENT <br /> Data Length = 8 <br /> The RS-232 port needs to be connected to the VSAT's Port 3 if the site has already been set-up and configured to communicate SINGLE DOUBLE SINGLE DOUBLE SUMP DISPENSER 'INTERSTITIA Nominal Capacity < This is the generic lank size. <br /> via the satellite (Consult Polecat Administrator if you have questions regarding this connection @a 281-874-7834). WALL WALL WALL WALL AREA AREA AREA <br /> TANKS TANKS PIPING PIPING Low Product Limit < When tank guage float reaches this level of product in tank, the product line will be disabled. <br /> REQUIRED CONNECTION EQUIPMENT <br /> PIS - 232 Serial Port Satellite (VSAT) Board 3.0 gph LINE FAILURE YES YES Delivery Limit < A warning will sound that product has reached this level in tank. Delivery order should be confirmed. <br /> Compatible Category 5 Shielded Communications Cable w/DB-25 Connectors. 2 gph LINE SINGLE FAILURE NO NO <br /> Shut down for that tank will occur at low product limit if delivery not received. <br /> PINS: (2 = SEND) (3 = RECEIVE) (7 = GROUND) (20 = DTR straight through end to end) I _— _ _ _ ___ Overfill Limit < This is the first level alarm setting which will track tanks filled to 95% of manufacturer's actual capacity. <br /> Laptop computer programmed with V-R diagnostics or Pro-Com software or use Hyper-Link to test cable, VSAT board and TLS 350. .1 gph LINE SINGLE FAILURE NO NO High Level Limit < This is the second level alarm setting which will track tanks filled to 98% of manufacturer's actual capacity. <br /> Communications Break-Out Box or Mini-Tracker also highly recommended for trouble-shooting of communications problems. r- <br /> Full Volume < This is the gallon amount to be programmed into the Veeder-Root which reflects manufacturer's actual <br /> .2 gph PROGRAMMED g p g <br /> IN-TANK SETUP PERIODIC ALARM NO NO capacity for tank as published on the location-specific tank chart. <br /> Follow normal setup procedures. Use the following information as a standard --- Maximum or Label < This is the gallon amount to be programmed into the Veeder-Root which reflects manufacturer's actual <br /> ProduProduct Co ng.........2" .Refor o Tablefer to Table <br /> blended fuel)- Check OS labeling and verify compatibility HIGHhTANK WATER FAILURE Y O Y O — Volume Limit entered foorFull Volunk as e. Th published is not the geneon the nicPnom necific oank chart.minal capacity nulmbe tuber must match the number <br /> Product Code.... .......... .. Refer 4o Table B <br /> Water <br /> CH <br /> ES <br /> High Water Alarm.....3" IT' for ETCH blended fuel) <br /> Maximum or Label Limit.... .Refer to Table C (Tank actual capacity per manufacturer's tank chart) LEAK ALARM YES YES POLECAT COMMUNICATIONS SET-UP PROTOCOLS <br /> Overfill Limit,..,.-.................Refer to Table C SUDDEN OSS NO NO Relay Type...................Standard <br /> High Level Limit.............._...RefertoTableC I .._ _._ Relay Orientation..........Normally Closed <br /> Delivery Limit.......................Refer to Table C LOW LEVEL YES YES Assignment Method......in Tank Alarm...Each Tank...High Water, Low Fuel <br /> Low Level Limit................... Refer to Table C LINE SHUTDOWN ON THIS ALARM CONDITION! — --___ Assignment Method..,...Liquid Sensor Alarms...by Sensor; Fuel, High Liquid, Low Liquid <br /> Leak Alarm Limit.-...-50 Gallons LINE SHUTDOWN ON THIS ALARM CONDITION! SENSOR ALARMS YES YES NO Assignment Method......3 Wire CL Alarms...by Sensor.....Fuel, High Liquid <br /> Sudden Loss limit......50 Gallons — - <br /> Tank Tilt,.......If probe is mounted in the center of the tank tilt should be set at 000.00. If the probe is not <br /> in the center follow instructions in the most recent Veeder-Root set-up manual for calculating tank tilt. <br /> SINGLE TANK Must be selected and assignment of alarms must be associated with the appropriate tank and sensors. <br /> DO NOT USE TANK TILT TO MATCH THE MANUAL STICK READINGS. <br /> IN MOST CASES THE TLS-35OR SHOULD NOT MATCH THE STICK. IN TANK ALARMS High Water ----------- Water level in tank has reached the programmed point. <br /> Low Fuel ------------ Fuel level in tank has dropped below the low level limit. <br /> IN-TANK SETUP Periodic Leak -------- A periodic leak is a .2 gallon per hour test. <br /> Leak Min Annual ......................50% LIQUID SENSOR Fuel ------------------- This applies to a sensor which is installed in the sump or interstitial area of the tank. <br /> Leak Periodic Test Type...........25% High Liquid ----------- Applies to the Brine sensor in the interstitial area of the bank. <br /> Periodic Test Type....................Standard Low Liquid ------------ Applies to the Brine sensor in the interstitial area of the tank. <br /> Annual Test Fail.......... .........Disabled <br /> Periodic Test Fail......................Disabled 3 WIRE This sensor is installed in the containment sumps and will not shut the pump down for water unless the water <br /> Gross Test Fail..........................Disabled CURRENT LOOP reaches the HIGHEST point on the sensor. It will then shut the line down with a "High Liquid" alarm and fuel alarm. <br /> Annual Test Averaging..............Off <br /> Periodic Test Averaging............Off <br /> Tank Test Notify......................_Off TABLE B <br /> Tank Test Siphon Break............Off — -- <br /> Delivery Report Delay........... ...1 Minute; Manifolded tanks only...5 mins or greater L <br /> Meter Data.................................Yes PRODUCT LABEL TANK * PRODUCT <br /> End Factor.......... ......................None/O (for BIR only) LOCATION CODE <br /> Cal Update.................................Immediate <br /> IN-TANK AUTO LEAK TEST SETUP DATA <br /> I UNLEADED REGULAR 1 1 <br /> Leak Test Method.......................All Tanks — <br /> Leak Test Frequency...... ...........CSLD ( .2 gph test) UNLEADED PLUS 2 2 <br /> Gross Test Auto-Confirm....,.......Disabled <br /> Report Only.................................Disabled SUPER UNLEADED 3 3 <br /> Test Early Stop............. t. ........Disabled DIESEL 4 4 <br /> Leak Test Report Format............Disabled <br /> Changes made to existing locations must be phoned in to Polecat Admin . <br /> KEROSENE 5 T <br /> PRESSURIZED LINE LEAK DETECTOR SETUP _ <br /> 0.10 GPH Test............................Enabled/Repetitive from the location , and communication must be confirmed . <br /> 0.20 GPH Test............................Enabled/Repetitive Manifolded Tanks Example <br /> Shutdown Rate...........................3.0 GPH only <br /> Low Pressure Shutoff..... .....Yes <br /> TANK * PRODUCT <br /> Low Pressure..............................5 PSI PRODUCT LABEL LOCATION CODE <br /> 2.0" DIA Length..........................Actual (>100 ft.) Default is 501 feet and must be changed <br /> RECONCILIATION SETUP (Automatic monthly printout) UNLEADED REGULAR 1 1 <br /> Automatic Daily Closing..............Default (2:00am) -- <br /> Automatic Shift Closing........... ...Not used UNLEADED REGULAR 2 1 <br /> Periodic Reconciliation Mode..... Monthly <br /> Periodic Reconciliation Alarm......Disabled SUPER UNLEADED 3 3 <br /> NOTE: Please refer to your State and Local Regulations regarding when a reconciliation report must be printed. You must SUPER UNLEADED 4 3 <br /> program Periodic Reconciliation for Rolling if you are required to generate a report on a given number of days. I - <br /> 'Tank Location - This is the preferred tank layout as it applies the TLS-350 channels. <br /> With manifolded tank applications this will not be possible, however, the product order <br /> should be maintained. <br /> These drawings and specifications are the confidential and APPROVALS <br /> proprietary property of Shell Oil Products US and shall not be shell Oil Products US 0 0 0 CALIFORNIA U .S.T. STANDARDS <br /> copied, reproduced, disclosed, or used 'without Shell Cil DISTRICT MANAGER <br /> Products US written authorization. They are intended as I I <br /> contract documents for use on this specific project in - ❑ - - — D 0lJ U L E V V/-'ALL FIBERGLASS Y11 \ r\ <br /> on s Issue de not suitable or use on --. otiva Enterprises LLC AREA TECHNICAL MANAGER <br /> conjunction with itiuate and ore f <br /> a different project or at a later date. GRAPHIC SCALE TERMINAL MANAGER V E E D E R — ROOT SPECIFICATIONS <br /> 1 10/31 02 CLARIFICATION /CHANGES jjR 12700 Northborough Drive SCALE: SAP/WIC # DATE: DRAWN: REQUESTED BY: <br /> © Shell Oil Products US. All Rights Reserved 2002 REV DATE DESCRIPTION OF REVISION BY APP Houston -rX 77067-2_508 ENGINEER -- E01 031 500 <br /> NONE 800062 03 MAY 2002 RABAGO HOVLAND <br />