Laserfiche WebLink
�„� ..... .- ....�..��.....a_.��.u.�_. _a.� NOTES: <br /> - — — -- -- - - -- ELECTRONIC MONITORING SYSTEMS (PER "APPROVED MATERIALS LIST") PROVIDES <br /> — ADVANCED AUTOMATIC CONTROL OF UNDERGROUND TANK AND PIPING INSTALLATIONS. <br /> EXPLOSION PROOF " USE SENSOR DETAIL FOR TURBINE AND FILL SUMP EACH MONITORING SYSTEM CAN BE CONFIGURED TO PROVIDE SIMULTANEOUS REAL <br /> JUNCTION BOX TIME SURVEILLANCE OF SEVERAL DIFFERENT INSTALLATION PARAMETERS WITH <br /> ADJUSTABLE AUTOMATIC ALARM NOTIFICATION AND AUTOMATIC SHUTDOWN OF SELECTED COMPONENTS <br /> LEADER CABLE IN THE ADVENT OF DEVIATIONS FROM INTENDED OPERATIONS. SENSOR DESCRIPTIONS <br /> RISER VENT SENSOR CABLE AND CLASSIFICATIONS ARE NOTED BELOW. <br /> (SEE NOTE CABLE GRIP <br /> [-NONCORROSIVE <br /> Si CONTINUOUS MONITORING OF PRESSURIZED PRODUCT PIPING TO TEST, ALARM, <br /> RISER <br /> PIPE AND SHUT DOWN TURBINE IF LEAK OCCURS. SENSOR IS MANDATORY. <br /> \ <br /> \I <br /> CAP <br /> b S2 CONTINUOUS MONITORING OF SECONDARY CONTAINMENT PIPING AND TURBINE <br /> SENSOR aSUMP FOR INTRUSION OF ANY LIQUID. SENSOR IS TO BE INSTALLED SUCH <br /> MFGR <br /> THAT ANY ALARM WILL SHUT DOWN TURBINE IF FUEL IS DETECTED. SENSOR <br /> _ IS MANDATORY. <br /> I I � S3 CONTINUOUS SIMULTANEOUS MONITORING OF TANK INNER AND OUTER WALLS <br /> BY HYDROSTATIC MEANS. IF INTERSTITIAL LIQUID (WATER OR SALT BRINE) <br /> FITTING <br /> L J —P PER SEAL OFF / \ LEVEL GOES UP OR DOWN BEYOND LIMITS, SENSOR WILL ALARM BUT SHUT <br /> I/ NOTHING DOWN AS SUCH ACTION WILL NOT ARREST THE PROBLEM. HOWEVER, I\ INTERSTITIAL LIQUID WILL NOT PERMIT PRODUCT TO ESCAPE DUE TO HIGHER <br /> LIQUID DENSITY AND HIGHER HYDROSTATIC HEAD REGARDLESS OF INVENTORY <br /> 4„0 <br /> LEVEL. SENSOR IS MANDATORY FOR SUCH TANKS. <br /> INTERNALLY INT \ S4 CONTINUOUS MONITORING OF TANK RISER INTERSTII, IF RISERS ARE CONTAINED. <br /> INTRIN SENSOR <br /> THREADED <br /> APE SENSOR O SENSOR WILL AUTOMATICALLY ALARM IF ANY LIQUID INTRUDES INTO INTERSTII, <br /> SADJUSTABLE CONDUIT TO LEAK DETECTION PANEL IN BLDG. 318" x 3" CLEVIS I ; BUT WILL SHUT NOTHING DOWN AS SUCH WILL NOT ARREST THE PROBLEM. <br /> S3 LEAD CABLE W/COTTER PIN TANK SENSOR IS OPTIONAL. HOWEVER, IF RISERS ARE CONTAINED, SENSOR CONDUITS <br /> MUST ALSO BE INSTALLED FOR POSSIBLE FUTURE USE. SINCE CONDUITS ARE <br /> NOTE: PART OF SAID CONTAINMENT, SAID CONDUITS MUST PASS BOTH N.E.C. CONTINUITY <br /> INSTALL 1/4 PQLYFLOW TUBE TO GRADE / TEST AND PRESSURIZED LEAK TEST. <br /> IF GROUND WATER MAY EXCEED RISER HEIGHT ASS SL VE <br /> (SMITH OR APIPE) <br /> I I CONTAINMENT SUMP IF THESE RISERS ARE.CONTAINED IN A SUMP, SUBSTITUTE AN S2 TYPE <br /> PERFORATED or SLOTTED <br /> /� SENSOR AND WIRE IT TO ALARM, THIS WILL SHUT DOWN NOTHING. <br /> ENTIRE LENGTH OF SLEEVE. <br /> TO BE ATTACHED TO SIDE OF I / S5 CONTINUOUS PRODUCT INVENTORY LEVEL MONITORING. CAN BE PROGRAMMED <br /> RISER PIPE CAP JUNCTION SUMP USING METHACRYLATE ADHESIVE. { I I S2 EXPLOSION—PROOF JUNCTION BOX TO PROVIDE LOW INVENTORY LEVEL WARNING, HIGH INVENTORY LEVEL ALARM, <br /> AND FITTINGS Box SUMP WALL WATER WARNING, AND AUTOMATIC TANK LEAK TEST TO .01 GPH ACCURACY PER <br /> 2" THREADED <br /> ABS TO BLDG S2 \ USEPA PROTOCOL. SENSOR IS OPTIONAL BUT CONDUITS FOR SENSOR MUST <br /> BE INSTALLED AND MUST PASS BOTH AN N.E.C. CONTINUITY TEST AND A <br /> PIPE RISER PRESSURIZED LEAK TEST. <br /> INTRINSICALLY <br /> SAFE SENSOR SENSORFIBERGLASS <br /> AND 2"0 PERFORATED S6 CONTINUOUS MONITORING OF DISPENSER SECONDARY CONTAINMENT SPACE FOR <br /> � I FIBERGLASS SLEAVE TO BE PLACED <br /> ON SIDE OF SUMP THAT PRODUCT INTRUSION BY ANY LIQUID. SENSOR WILL AUTOMATICALLY ALARM AND SHUT DOWN <br /> SENSOR TO BE 1/2" (MAXIMUM) PIPING PENETRATES SUMP. OFFENDING DISPENSER (NO ELECTRICAL POWER TO SAID DISPENSER) SHOULD <br /> FROM LOWEST SPOT IN SUMP WASS' SENSOR TO BE PLACED (i ANY FUEL BE DETECTED. SENSOR IS MANDATORY. <br /> RISER PIPE 1/2" (MAX) FROM LOWEST POINT <br /> RESERVOIR IN SUMP. A ADDITIONAL SENSORS CAN BE UTILIZED, BUT MUST FIRST BE APPROVED BY <br /> FRP RESERVOIR SENSOR <br /> S3 A A A HEAD OFFICE MARKETING ENGINEERING STAFF UNLESS GENERAL SPECIFICATIONS <br /> SECTION A- <br /> LIQUID MONITORING FLUID OR "APPROVED MATERIALS LIST" IS REVISED TO SHOW APPROVALS OF SAME IN <br /> THE FUTURE. <br /> NOTE FOR ELECTRICIANS: ALL SENSITIVE CIRCUI'T'S (SENSORS, DATA, ETC) <br /> SHALL BE ROUTED IN METALLIC CONDUIT AROUND (NOT THROUGH) WIRE <br /> DOUBLE WALL FIBERGLASS TANK TROUGH IN BUILDINGS. FAILURE TO COMPLY MAY CAUSE SYSTEMS TO PICK UP <br /> INDUCTIVE NOISE THAT DISRUPTS INTENDED OPERATION OF SENSITIVE DEVICES. <br /> S3 <br /> SEE EO103120 tT <br /> NIVERSAL #62 8" CONC <br /> j I �I PVC RISER PIPE SEE 'I S1 m ho TIGLOGHTULOCKINKi ACCESST60 SSB. j OBSERVATION WELLS <br /> 1 B <br /> T E01031200 AT LEAST ONE WELL IN <br /> UNPERFORATED '.'l,-III TANK HOLE. AREA TO BE <br /> CASING 24" MOUN 8" CASING CONFIGURATION <br /> IF IDEER 1_1/2 AS SHOWN BELOW. <br /> N-� <br /> S3 52 <br /> 12° NITRILE KEYLOCK <br /> PEAGRAVEL FIL-SEAL-PAK JOINT (TYP) <br /> I I BACKFILLS LINER WITH <br /> ✓ STAINLESS SOME STATES HAVE PERMIT REQUIREMENTS FOR WELLS. IT WILL BE THE <br /> II BAND CLAMPS, I INSTALLING CONTRACTOR'S RESPONSIBILITY TO KNOW SAID CODE <br /> REQUIREMENTS AND TO OBTAIN REQUISITE PERMITS, PRIOR HEAD OFFICE <br /> I 4" SCHED 40 PVC COMPANY ENGINEERING APPROVAL IS REQUIRED FOR ANY SIGNIFICANT <br /> I II <br /> I BOTTOM OF TANK WELL CASING WITH TANKS DEVIATIONS FROM ABOVE, IF LOCAL CODES DO NOT REQUIRE WELLS BUT DO <br /> II I HOLE EXCAVATION. CONTINUOUS 020" REQUIRE REGULAR MONITORING IF INSTALLED, DO NOT INSTALL UNNECESSARY <br /> I MACHINED SLOTS & OBSERVATION WELLS. <br /> THREADED CONNECTIONS. <br /> \ (NO GLUED JOINTS) LOCAL JURISDICTIONS MAY HAVE THEIR OWN REQUIREMENTS. IF THIS IS THE <br /> L <br /> CASE, CONTACT THE LOCAL ALLIANCE COMPANY ENVIRONMENTAL ENGINEER. <br /> � I <br /> All <br /> 12" MIN, WELL <br /> TYPICAL // <br /> TYPICAL DOUBLEWALL FIBERGLASS TANK TANK SLAB" <br /> THRETHREADED PVC CAP <br /> RNCO QUIK-CAP. — -- -- <br /> REFERENCE DRAWINGS - E01031500; E01032700 <br /> These drawings and specifications are the confidential and APPROVALS <br /> proprietary property of Shell Oil Products US and shall not be 4 10/31/02 ADDED SLEEVE NOTES 'jR Shell Oil Products US 0 0 0 CALIFORNIA U .S.T. STANDARDS <br /> copied, reproduced, disclosed, or used without Shell Oil DISTRICT MANAGER. <br /> Products US written authorization. They are intended as 3 04/12/02 ADD NEW DETAILS (2) ADRY ��}} IE'--�� ��( /� I TANK/PIPING <br /> ghl �/ (� <br /> contract documents for use on this specific project in ❑ D V U D L�_ VV/'LLL A V K/P I P I N G <br /> corjunction with its issue date and are not suitable for use on 2 02/14/02 ADD NON—MANDATORY OBSERVATION WELL ADRY Motiva Enterprises LLC AREA TECHNICAL MANAGER <br /> a different project or at a later date. ___ _____ DIAGRAM FROM "DELETED DWG. E01031800" --- P TERMINAL MANAGER GRAPHIC SCALE ELECTRONIC M 0 N ITO R I N G DETAILS <br /> 1 02/11 /02 CLARIFICATION / CHANGES ADRY 12700 Northborough Drive SCALE: SAP/WIC # DATE: DRAWN: REQUESTED BY: <br /> Shell Oil Products US. All Rights Reserved 2002 REV DATE DESCRIPTION OF REVISION BY APP Houston TX 77067-2508 ENGINEER <br /> NONE 800062 03 MAY 2002 RABAGO HOVLAND E01031400 <br />