Laserfiche WebLink
Jun 0706 09,32p Mike Qotten 209-533-2650 p•4 <br /> i <br /> Facility: Linden Associated Growers Page 2 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: N/A <br /> Complete the fullowing checklist: <br /> Yes ❑ No* ]s the audible alarm o erational? <br /> Yes ❑No* Is the visual alarm operational? <br /> El Yes ❑ No* is the-print function operational? M Not:installed. <br /> E Yes ❑ No* Were all sonsoTs.visually inspected, functionally tested,and confirmed o erational? <br /> Z Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will ` <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g, modem) <br /> N/A operational? <br /> ❑Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> NIA monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) ❑ Sump/Trench Sensors; ❑Dispenser Containment Sensors. <br /> Didyou confirm positive shut-down due to leaks and sensor failure/disconnection? ❑Yes; ❑No. <br /> ❑Yes ® No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> NIA mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill oinx s and o eratin ro erl ? If so,at what Eercent of tank capacity does the alarm triMer?. <br /> ® Yes* ❑ No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or outer equipment replaced <br /> and list the manufacturer name and model for all re lacement parts in Section E, below. <br /> Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> JE Product; ® Water. If Xes, describe causes in Section E,below. <br /> Yes ❑ No* Was monitoring system set-up reviewed to ensure ploper settings?Attach set up rel2orts,if a licable <br /> Yes ❑ No* Is all monitori! a ui mentoperational per manufacturer's ecifications? <br /> *In Section E below,describe bow and when these deficiencies were or will be corrected. <br /> E. Comments: No Deficiencies. <br /> Page 2 of 03/01 <br />