My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
14175
>
2300 - Underground Storage Tank Program
>
PR0234383
>
COMPLIANCE INFO_1992-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/7/2018 12:04:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2005
RECORD_ID
PR0234383
PE
2361
FACILITY_ID
FA0003670
FACILITY_NAME
REYNOLDS PACKING CO QUALITY BIN
STREET_NUMBER
14175
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
051-050-05
CURRENT_STATUS
02
SITE_LOCATION
14175 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\T\HWY 26\14175\PR0234383\COMPLIANCE INFO 1992-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
274
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jun 14 05 10: 09p Mis Dotten 1200 533-2650 p. 1 <br /> w <br /> �+ V <br /> 17759 Buttercup Circle, Sonora, CA 95370 <br /> Phone: 2019-532-7320; Fax: 209-533-2650 <br /> California Contractor 623541 A-Haz <br /> alltech@getrocket.com <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information <br /> Facility Name: Linden Associated Growers Date of Testing/Servicing: May 26,2005 <br /> Facility Address: 14175 E.Hwy 26,Linden CA 95326 <br /> Facility Contact Person: Charlie Busalacchi Contact Phone No.: 209-9314800 <br /> Regulatory agency: San Joaquin Health; Inspector:John Jackson,Plione: 468-3440;Fax 468-3433 <br /> Make/Model of Monitoring System: Veeder-Root ILS-250 <br /> This test report is it: ❑Preliminay Report nresolved Issues Exist or a_M Final Re ort acifi was observed to be in Compliance) <br /> Tank ID:Gasoline Compartment Tank ID:Diesel Compartmant E <br /> ❑In-Tank Gauging Probe. Model:None ❑In-Tank Gauging Probe. Model:Noise <br /> M Annular Space or Vault Sensor. Model:Float Switch M Annular Space or Vault Sensor. Model:Shared with Gas side <br /> ❑Piping Sump/Trench Sensor(s)_ Model:None ❑Piping Sump/Trench Sensor(s). Model:None a <br /> ❑Fill Sump Sensor(s). Model:None ❑Fill Sump Sensor(s). Model:None is <br /> El Mechanical Line Leah Detector. Modal:Nona ❑Mc t hanical Line Leak Detector, Model:None <br /> ❑Electronic bine Leak Detector. Model:None ❑Electronic Line Leak Detector. Model:None <br /> M Tank Overfill/Iiigh-Level Sensor, Model:Drop Tube M Tank Overfill/High-Level Sensor. Model:Drop Tube <br /> M Fillspill buckets tested ❑Pass MFail M Fillsliill buckets tested ❑Pass MFail <br /> Other ❑Other <br /> Tank ID: Tank 1D: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor, Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/'french Sensor(s). Model: ❑Piping Sump l Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑lilt Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Lime Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/I-figh-Level Sensor. Model: ❑Tarok Overfill/High-Level Sensor. Model: <br /> ❑Fillspill buckets tested ❑Pass ❑Fail ❑Fillspill buckets tested ❑Pass ❑Fail <br /> ❑Other ❑Other <br /> Dispenser ID:Gas M Sump:®Dry[]Water❑Produc€ Dispenser ID: Diesel Z Sump:ZDry❑Water❑Product <br /> M Dispenser Containment Sensor(s). Model:Float SW. Z Dispenser Containment Sensor(s), Model:Float Switch <br /> Shear Valve(s) (Functional test) ❑Shear Valvc(s) (Functional test) <br /> ❑Dii iscr Containment Float(s)and Chains Q Containment Floa€(s)and Chains. <br /> Dispenser ID: ❑Sump:❑Dry❑Water❑Product — — Dispenser ED: ❑Sump:❑Dry❑Water❑Product <br /> El Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s) (Functional test) ❑Shear Valve(s) (Functional test) ! <br /> ❑Dis nser Contai uvent Flo<at(s and Chains . L]Dis eraser Containment Float(s)and Chains . <br /> Dispenser ID: ❑Sump:❑Dry❑Water❑Product Dispenser ID: ❑Sump:[]Dry❑Water❑Product <br /> ❑Dispenser Containment Scmsor(s). Madel: ❑Dispenser Contaimnent Sensor(s)- Model: <br /> ❑Shear Valves) (Functional test) ❑Shear Valve(s) (Functional test) <br /> ❑Dis nser Containment Floats and Chain(s). ❑Dispenser Containment Float(s)and Cliain(s . <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' -guidelines- Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this <br /> information is correct and a Plat Plan showing the layout of monitoring equipment For any equipment capable of generating such <br /> reports,I have also attached a cpp�thhc ort (cheelr all thal apply): ❑ System set-up ❑Alarm history report <br /> Technician: M�_ _Mike Dotten,California Contractor License.No.:623541 - <br /> Certification:Veeder-hoot: 341-32-6743;Level 4. ICC UST Technician#5259412 — U-r <br /> Page 1 of 3 03101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.