My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
14175
>
2300 - Underground Storage Tank Program
>
PR0234383
>
COMPLIANCE INFO_1992-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/7/2018 12:04:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2005
RECORD_ID
PR0234383
PE
2361
FACILITY_ID
FA0003670
FACILITY_NAME
REYNOLDS PACKING CO QUALITY BIN
STREET_NUMBER
14175
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
051-050-05
CURRENT_STATUS
02
SITE_LOCATION
14175 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\T\HWY 26\14175\PR0234383\COMPLIANCE INFO 1992-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
274
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jun 22 03 05: 32p MAP Dotten 20933-2650 p. 2 <br /> D. Results of Testing/Servicing <br /> Software Version Installed; N/A <br /> Complete the follo ing checklist: <br /> ® Yes ❑ No* Is the audible alarm operational? <br /> ®Yes ❑ No* is the visual alarm operational? <br /> ❑Yes ❑ No* Is the print functionoperational? ®Not installed. <br /> ®Yes ❑ No* Were all sensors visually ins ected, functionally tested,and confirmed operational? <br /> I Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their proper o eration? <br /> ❑Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> ® NIA operational? <br /> ❑Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ® NIA monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-dawn? (Check all that apply) ❑ Sump/Trench Sensors; ❑Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failureldisconnection? ❑Yes; ❑No. <br /> ❑Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> ® NIA mechanical overfill prevention valve is installed), is the overfill roaming alarm visible and audible at the tank <br /> fill oint(s)and o eratin ro erl ? If so,at what percent of tank capacity does the alarm tri4ginI <br /> JZ Yes* ❑ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in.Section E,below. <br /> Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> 0 Product; ® Water. ff es,describe causes in Section E,below. <br /> ®Yes ❑ No* Was monitoring stem_ set-up reviewed to ensure j2roper settings?Attach set up re orfs,if applicable <br /> Yes ❑ No* I Is all monitorina equipmentoperational per manufacturer's s cifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. El <br /> E. Comments: Drop Tube was replaced on the Gasoline side to pass a Vapor Recovery test. 'there was a small <br /> amount of product/water under each of the dispensers. This was removed with shop towels (rags) and processed by the <br /> laundry with the other soiled shop towels. <br /> rets /k), Page 2 of 3 03lD1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.