My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2358
>
2300 - Underground Storage Tank Program
>
PR0231756
>
COMPLIANCE INFO 2013 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 4:59:40 PM
Creation date
11/7/2018 9:03:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2016
RECORD_ID
PR0231756
PE
2361
FACILITY_ID
FA0006343
FACILITY_NAME
ALPHA FAST GAS*
STREET_NUMBER
2358
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14118221
CURRENT_STATUS
01
SITE_LOCATION
2358 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\2358\PR0231756\COMPLIANCE INFO 2013 - 2016.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2016
QuestysRecordDate
8/8/2018 4:42:56 PM
QuestysRecordID
3958640
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ALPHA FAST GAS* 2358 E WATERLOO RD STOCKTON Aril 23 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,GLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months. <br /> The January 2015, February 2015, and March 2015 designated operator monthly inspection reports were not found on <br /> site. Designated operator monthly inspection reports for the previous twelve months shall be retained on site. Copies <br /> of these inspection reports were emailed to the facility by the designated operator at the time of inspection. This was <br /> corrected on site. <br /> This is a repeat violation, Class 11. <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br /> The diesel annular sensor failed to activate an audible and visual alarm when tested and, therefore, the tank was not <br /> monitored. The interstitial space shall be monitored with a monitoring system connected to an audible and visual <br /> alarm system. The technician smacked the sensor several times and it began working. This was corrected on site. <br /> This is a Class 11 violation. <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br /> The Bravo box float and chain in the Dispenser 718 (W) UDC sump failed to stop the flow of product at the dispenser <br /> when tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of <br /> product at the dispenser when it detects a leak. The service technician adjusted the chain(s)and verified functionality. <br /> This was corrected on site. <br /> This is a repeat violation, Class ll. <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 87 VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting <br /> a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it passed_ This <br /> was corrected on site. <br /> This is a repeat violation, Class 11. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by May 23, 2015. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: 'Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Received by Inspector: Phone: Date: <br /> (initial): STACY RIVERA, Senior REHS (209) 468-3440 0412312015 <br /> Page 5 of 6 <br />