My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4407
>
2300 - Underground Storage Tank Program
>
PR0231761
>
COMPLIANCE INFO 2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 4:34:37 PM
Creation date
11/7/2018 9:23:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231761
PE
2361
FACILITY_ID
FA0002347
FACILITY_NAME
ERNIES GENERAL STORE
STREET_NUMBER
4407
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710059
CURRENT_STATUS
01
SITE_LOCATION
4407 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\4407\PR0231761\COMPLIANCE INFO 2011-2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,danuary2002 • <br />0 Page of <br />8. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps X <br />Fill Riser Containment Sumps are Present, but were Not T9sted <br />Test Method Developed By: D Sump Manufacturer D Industry Standard Professional Engineer <br />D Other (Spec) <br />Test Method Used: D Pressure D Vacuum Hydrostatic <br />0 Other (Spec6) <br />Test Equipment Used: <br />Fill Sump # Fill Sump # <br />Equipment Resolution: <br />Fill Sump # <br />Fill Sump # <br />Sump Diameter: <br />Sump Depth: <br />Height from Tank Top to Top of <br />Hi hest Pi in Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to <br />testing: <br />Portion of Sump Tested <br />Sump Material: <br />Wait time between applying <br />water and starting test: <br />Test Start Time: <br />Initial Reading (R,): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Chane in Reading (RF-Rj): <br />Pass/Fail Threshold or Criteria: <br />Test Result. " <br />,,.Pass' ` D Fail <br />Pass O,Fail <br />Pass ❑'Fail <br />0 Pass D Fail <br />Is there a sensor in the sump? <br />Yes 0 No <br />Yes 0 No <br />Yes D No <br />❑ Yes D No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />Yes D No DNA <br />Yes 0 No 0 NA <br />Yes 0 No 0 NA <br />0 Yes 0 No D NA <br />Was sensor removed for testing? I <br />Yes 0 No 0 NA <br />Yes 0 No 0 NA <br />Yes 0 No D NA <br />0 Yes D No D NA <br />Was sensor properly replaced and <br />verified functional after testing? I <br />Yes D No D NA <br />Yes 0 No DNA <br />Yes D No DNA <br />D Yes D No D NA <br />Comments — (include information on repairs made prior to testing, and recommended allow -up forfalled tests) <br />