My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2002 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 3:04:48 PM
Creation date
11/7/2018 10:05:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2004
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4040\PR0231963\COMPLIANCE INFO 2002 - 2004 .PDF
QuestysFileName
COMPLIANCE INFO 2002 - 2004
QuestysRecordDate
7/26/2018 10:41:38 PM
QuestysRecordID
3948516
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
205
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 5 of 7 <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: UDC Manufacturer Industry Standard X Professional Engineer <br /> Other(Specify) <br /> Test Method Used: Pressure Vacuum X Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Incon 0 TS-STS Equipment Resolution:Hndrd Thsnds <br /> UDC# 1 UDC# 2 UDC# 3 UDC# <br /> UDC Manufacturer: Western Fiberglass Western Fiberglass Western Fiberglass <br /> UDC Material: Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 28" 28" 28" <br /> Height from UDC Bottom to Top <br /> of Hi hest Piping Penetration: 10" 10" 10" <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: 41' 4" 4" <br /> Condition of UDC prior to <br /> testin Clean Clean Clean <br /> Portion of UDC Tested 12" 12" 12" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both Res 11No <br /> [INA RYes[]No []NA HYes F]No []NA Yes 11No []NA <br /> product and water)?` <br /> Turbine shutdown response time 60 Seconds 60 Seconds 60 Seconds <br /> Is system programmed for fail- <br /> safe shutdown?` Eyes No NA E]Yes❑No F]NA Yes ❑No []NA Yes ❑No []NA <br /> Was fail-safe verified to be <br /> o erational?` "Ryes No NA 2 Yes®No [JNA Yes []No NA Yes 0 Na NA <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test 30 Min 30 Min 30 Min <br /> Test Start Time: 12:48 12:48 12:48 <br /> Initial Reading(Ri): 6.5135 1.6030 2.3822 <br /> Test End Time: 13:03 13:03 13:03 <br /> Final Reading(RF): 6.4594 1.6029 2,2373 <br /> Test Duration: 15 Min 15 Min 15 Min <br /> Change in Reading(RF-Ri): 0.0545 0.0001 0.1449 <br /> Pass/Fail Threshold or Criteria: 0.002 Inches 0.002 Inches 0.002 Inches 0.002 Inches <br /> Test Result: 0 Pass EDFail 21 Pass ❑Fail ❑ Pass El Fail ❑ Pass ❑ Fail <br /> Was sensor removed for testing? 21 Yes ❑No❑ NA ✓ Yes No❑NA 0 Yes❑No DNA ❑Yes❑No❑NA <br /> Was sensor properly replaced and ® ❑ ® r E]N []Yes[] ❑ <br /> verified functional after testing? '�Yes No NP_ Yes[]No A �/Yes No NA 1 es No NA <br /> veri <br /> 11 <br /> COMMUItS— (include information on repairs made prior to testing, and recommended follow-u for failed tests) <br /> Under Dispenser Containment Testing(UDC#1 -Unleaded)Leaking at secondary test boot and conduit <br /> entry boot. <br /> Under Dispenser Containment Testing(UDC#1A- Unleaded) - Passed. <br /> Under Dispenser Containment Testing(UDC#2 Diesel) Leaking around conduit entry boot. <br /> Recommendations: Pull dispensers, remove pasco tape from conduit. Reseal and retest. <br /> UDC #1 Needs new test boot. See page 3 for recommendations. <br /> 1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to air of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.