My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2002 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 3:04:48 PM
Creation date
11/7/2018 10:05:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2004
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4040\PR0231963\COMPLIANCE INFO 2002 - 2004 .PDF
QuestysFileName
COMPLIANCE INFO 2002 - 2004
QuestysRecordDate
7/26/2018 10:41:38 PM
QuestysRecordID
3948516
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
205
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 4 of 7 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: Sump Manufacturer Industry Standard X Professional Engineer <br /> Other(Specify) <br /> Test Method Used: Pressure Vacuum X Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Incon @ TS-STS Equipment Resolution:Hndrd Thsnds <br /> Sump# 1 Sump# 2 Sump# Sump# <br /> Sump Diameter: 48° 48" <br /> Sump Depth: 30" 3011 <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: 12" 12" <br /> Height from Tank Top to Lowest <br /> p i p <br /> Electrical Penetration: {911 o <br /> Condition of sump prior to testing: Clean Clean <br /> Portion of Sump Tested' 14" 14" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both Ryes —]No NA Yes®No NA Yes❑No []NA Yes No []NA <br /> product and water)?' <br /> Turbine shutdown response time 60 Seconds 60 Seconds <br /> Is system programmed for fail-safe Yes[] No [INA I ]Yes❑No[]NA ®Yes[]No❑NA O Yes L]No[]NA <br /> shutdown? <br /> Was fail-safe verified to be <br /> operational?* Hyes 11 No [INA [i/ Yes[]No[]NA ❑YGs❑No❑NA []Yes❑No[]NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting <br /> test: 30 Min 30 Min 30 Min 30 Min <br /> Test Start Time: 10:38 10:38 <br /> Initial Reading(Rj): 6,2123 7.2457 <br /> Test End Time: 10:53 10:53 <br /> Final Reading(RF): 6.0969 7.2455 <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-Ri): 0.1154 0.0002 <br /> Pass/Fail Threshold or Criteria: 0.002 Inches 0.002 Inches 0.002 Inches 0.002 Inches <br /> Test Result: E] Pass OFail E Pass L�] Fail. F—i Pass Fail 10 Pass Q Fail <br /> Was sensor removed for testing? ✓[lyes 0 No DNA OYes 0No ❑NA F]Yes❑No❑NA ®Yes[:]No[]NA <br /> Was sensor properly replaced and ® [I [I ❑ � ❑ ❑ []NA ❑ []No ❑ <br /> verified functional after testing? Yes No NA Yes No NA Yes No Yes NA <br /> Comments--(include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> Piping Sump#1 (PST 41)Dropped level of test fluid below penetrations,still leaking.Possibly around sump to tank mating area. <br /> Recommendation:Refiberglass sump to tank mating area and retest. <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*) is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />