My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1756
>
2300 - Underground Storage Tank Program
>
PR0231300
>
INSTALL_1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2019 11:50:48 AM
Creation date
11/7/2018 11:13:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1999
RECORD_ID
PR0231300
PE
2361
FACILITY_ID
FA0001858
FACILITY_NAME
MY MINI MART
STREET_NUMBER
1756
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11721005
CURRENT_STATUS
01
SITE_LOCATION
1756 N WILSON WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WILSON\1756\PR0231300\1999 INSTALL .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
itions.In ho <br /> Bonding primary The table indicates the adhesive pot life 1-11111:311916us tempa�Qnde the Bonn of m zedt <br /> systems (Cont.) weather,pot life may be extended by wrapping a damp rag <br /> adhesive or by spreading the adhesive on aluminum foil to dissipate the heat. �r <br /> Pot life/cure times for Ameron B20 adhesive <br /> Minimum Ambient Adhesive Minimum Joint <br /> Temperature Pot Life Cure Time' <br /> (minutes) (hours) <br /> 40 5 70 12 <br /> 65 18 40 5 <br /> 75 24 30 4 <br /> 95 35 20 3 <br /> Cumulative totals.Cure time at listed temperatures need not he <br /> uninterrupted,but total time must equal the tabulated time before <br /> the system is pressure tested. <br /> Force curing adhesive <br /> r—1 At temperatures below 40°F(5°C)or if the temperature will not be above 40°F(5°C) <br /> Temperatures may be lower during the entire period of cure,an external heat source must be used to force cure the <br /> than ambient in a trench or adhesive.The adhesive and the bonding surfaces should be warmed to 50°F(10°C) <br /> out of direct sunlight. before mixing and applying the adhesive. <br /> -- —� <br /> L--- <br /> ——!'— Below 40°F(5°C)farce cure the adhesive with an external heat source such as: <br /> • Chem Cure Pak(US Pat.No.3,475,239) <br /> • Ameron heating blanket sufficiently large to cover the joint <br /> • Forced air heater if the trench is covered to contain the heat <br /> • Hot air gun <br /> Using Chem Cure Pak with Ameron B20 adhesive <br /> The Chem Cure Pak is a self-contained,nonelectrical heat source for curing adhesive- <br /> bonded joints.Instructions are printed on the Pak wrapper.The Pak is designed so that <br /> sufficient heat'is generated to cure Ameron B20 adhesive in one hour at ambient <br /> temperatures as low as 0°F(-18'C).The Chem Cure Pak is manufactured in different <br /> sizes corresponding to the diameter of the piping being installed.Use the correct size <br /> Pak for your installation.Refer to table on page 11 when ordering. <br /> In cold weather,wrap insulation around the Pak as soon as it has stopped steaming. <br /> For lower temperatures or when installing extra-heavy fittings,consult Ameron for <br /> —————– specific recommendations. <br /> Chem Cure Pak contains oxalic Assemble pipe and fittings using standard field installation procedures. <br /> acid.Harmful if swallowed.Causes 0 Mix the chemicals thoroughly as directed on the Pak wrapper- <br /> skin and eye irritation. E • Wrap the Pak around the connections,centering it over the tapered section of <br /> L————————————J the joint,not over the end of the fitting.Cover the entire bonding area to which <br /> adhesive has been applied.Refer to Fig.7-1. <br /> • Use one Pak per bond:sleeve couplings in 3-inch sizes and larger require two <br /> Activator <br /> Paks.However,a single Pak is sufficient for curing both bonds in a 2-inch sleeve <br /> 1-in slot <br /> syringe Coupling. <br /> • Secure the Pak with tie wires. <br /> • Cut slits at least 1 inch wide(25 mm)on either side of the Pak. <br /> • Inject water into the slits with the activator syringe or pour in a small amount from <br /> +� a cup. <br /> Tie wiresCenter Pak over Aluminum fait may be wrapped directly over the joint to prevent the Pak from <br /> tapered area sticking if it is necessary that the expended Pak be removed from the trench. <br /> Fig.7-1.The Chem Cure Pak should Follow the precautions printed on the Chem Cure Pak wrapper: <br /> produce steam in about 30 seconds atter Do not get ingredients on skin,in eyes,or on clothing. <br /> injecting water.ffno reaction occurs, Do not breathe dust or vapor. <br /> discard the Pak and use anotherone. <br /> • Use only outdoors where adequate ventilation is provided. <br /> • Qo not take internally. <br /> • Keep out of reach of children. <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.