NPT threaded Thread preparation <br /> connections Inspect threads on fiberglass adapters and threaded bushings. <br /> Do not use if threads are damaged, <br /> • Inspect threads on steel fittings for burrs. <br /> • Remove burrs from steel fittings by making up to mating steel threads.Unmake <br /> the steel fitting and reinspect. <br /> r—————————————1 Always dry fit fiberglass and steel threads without sealing compound.It should <br /> In general,threaded connections I be possible to dry fit the threads as shown in the following table.If the proper <br /> I I <br /> should be made up before adhesive- number of threads cannot be made up,select a new steel fitting. <br /> I I <br /> bonded joints to minimize the I Making the joint <br /> I possibility of damage to bonded joints I Threads must be clean and dry before applying thread-sealing compound. <br /> 1 caused by torquing the threaded I <br /> I Use a nonhardening,solvent-free Teflon based thread sealant such as Jomar <br /> connections.However,when installing <br /> 1 molded threaded bushings(tapered I Seal"The Heavyweight"or Gasoila Soft Set pipe sealant, <br /> major nominal pipe size x threaded 0 Apply sealing compound to male and female threads. <br /> i minor nominal pipe size)make the a Hand tighten the joint,then <br /> I tapered bonded joint first and allow it I use a wrench to get full Threads to Dry Fit and to Seat <br /> to cure before making up the threaded I make-up.Standard pipe Nominal <br /> I joint.This order of joint make-up will I wrenches can be used with Pipe Size <br /> to the bushing. I care on fiberglass adapters: Threads to Additional <br /> prevent damage <br /> I g. 1 Do not overtighten. (in) (mm) Dry Fit Threads to Seal <br /> 11h 40 4-5 3 <br /> L— ———— ——I The parts should make up 2 50 4-5 3 <br /> the number of threads 3 80 5-6 3 <br /> shown in the table above. 4 100 6-7 2 <br /> Otherwise,a proper seal 6 150 7-8 2 <br /> may not be effected when <br /> tightened, <br /> Isolating flex connectors at the shear valve <br /> r--————•———— When flex connectors are directly buried at the dispenser,regulations frequently <br /> Never use a pipe I require that they be cathodically protected and provisions be made to avoid stray <br /> wrench directly on the current electrolysis and corrosion,In such cases the flex connector must be electrically <br /> I pipe:wrench up only I isolated from the shear valve and from other metallic components in the system, <br /> on adapters. I Fxperfence has shown that nylon isolation adapters do not perform weil inasmuch as <br /> L————r———J the poor mechanical strength of the material results in creep or thread deformation with <br /> subsequent leakage. <br /> Ameron manufactures a 11h NPTfemale x 1 1 NPT male fiberglass-reinforced <br /> isolation adapter which may be mounted between the flex connector and the shear <br /> valve. Follow the same general installation procedures as with other NPT threaded <br /> fittings.After applying the sealing compound,hand tighten the adapter.Final make-up <br /> requires 1112 to 2 additional turns. <br /> Shear valve <br /> 11/2 NPT female <br /> 2'/e <br /> 1112 NPT Dualoy isolation <br /> Fig,8-1.The Rmeron fiberglass-reinforced male adapter <br /> I <br /> isolation adapter is mounted between the <br /> flex connectorand the shear valve. 21/4 13/8 <br /> SS flex connector <br /> 1112 NPT 11/2 NPT male <br /> female both ends <br /> (by others) <br /> 12 <br />