My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
BILLING 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2023 10:34:31 AM
Creation date
11/7/2018 12:01:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2012-2015
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1434\PR0231465\BILLING 2012-2015.PDF
QuestysFileName
BILLING 2012-2015
QuestysRecordDate
6/26/2017 3:07:01 PM
QuestysRecordID
3465007
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
O FIED PROGRAM CONSOLIDATED FO <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- (Page 1 of 2 <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. T90-2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) <br /> J. <br /> BUSINESS NAME(Sam as Facility Name or DBA) Tower Mart#886 <br /> BUSINESS SITE ADDRESS 103. CITY io4 <br /> 1434 W Yosemite Ave. Manteca ,CA 95337 <br /> IL EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the equipment manufacturers'instructions,or annually,whichever is more fre uent Such work must be 2erformed by qualified personnel.[23 CCR§2632.2634,2638,26411 <br /> 490.14 <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490-3b. <br /> IH. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ® 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED Iz3 ccx§2632,2634) <br /> 490.4. <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (hara Irl) <br /> r <br /> ® L CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 4949. <br /> WITH AUDIBLE AND VISUAL ALARMS.(23 ccx 52632,M341 <br /> SECONDARY CONTAINMENT IS: ® a DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 49 <br /> PANEL MANUFACTURER: Veeder-Root <br /> g90.' MODEL#: TLS 350 49(3-8. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 490.9. MODEL#(S):794390-420 490.10. <br /> 2 AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANKS).[23 CCR§26,43] 490.11. <br /> 49°-12. MODEL#: 490-13. <br /> PANEL MANUFACTURER: <br /> a9o-u <br /> IN-TANK PROBE MANUFACTURER: 1-14. MODEL#(S): <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY <br /> [I d. <br /> d.MONTHLY ❑ e.OTHER(Specify): 49414. <br /> PROGRAMMED TESTS: ❑ s 0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 490-19. <br /> ❑ <br /> 49x2° <br /> 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 cm§2646.11 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23=§26491 <br /> TESTING PERIOD: ❑ a.36 HOURS [Ib.60 HOURS 490.21' <br /> 490.23. <br /> ❑ 5.TANK INTEGRITY TESTING PER In cm§2 m] <br /> TEST FREQUENCY: ❑ a.ANINIUALLY ❑ b.BIENNIALLY E] c.OTHER(Specify): 4voasz4. <br /> 490.26. <br /> ❑ <br /> 99.OTHER(Specify): 490.27. <br /> all <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Check l <br /> hot,, t <br /> ® 1.CONTINUOUS MONITORING OF PIPEIPIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490.26. <br /> 1v CCR SECONDARY CONTAINMENT IS: ® a.DRY [Ib.LIQUID FILLED ❑ c.PRESSURIZED Eld.UNDER VACUUM 49°'29' <br /> §26361 490.31. <br /> PANEL MANUFACTURER:Veeder-Root 490.30. MODEL#: TLS 350 <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 490.32" MODEL# 0794380-208 490.33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(Le.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a,YES ❑ b.NO 49°-35. <br /> ® 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 490.36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.(23 CM§26361 490.35 <br /> MLLD MANUFACTURER(S):FE Petro-STP-MLD VMI 490-J7. MODEL#(S):Va orless LD-2000 <br /> 490.19. <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[z3 Cm§26361 <br /> ELLD MANUFACTURER(S): 490`40' MODEL#(S); 40.41 <br /> 4 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.I gp.h. aA3, <br /> N <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a YES ❑ b.NO 9(3<J. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490-44. <br /> 49045. <br /> ❑ 4.PIPE INTEGRITY TESTING. 4W6 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 490.47. <br /> 490.45. <br /> ❑ 5.VISUAL PIPE MONITORING. <br /> FREQUENCY: ® a.DAILY ❑ b.WEEKLY ❑ a MIN.MONTHLY&EACH TINE SYSTEM OPERATED* 490-04 <br /> •Allowed fm mavrcoriv vfunbunad rotor fud ii and HSC 25281.5 <br /> 490.50. <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 cm§2636(.x3)1 <br /> 117.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.715 CONNECTED TO THE TANK SYSTEM. 49491. <br /> 490.52. <br /> ❑ 99.OTHER(Specify) 49x53' <br /> UPCF UST-D(12/2007)-1/4 www.unidou.org <br />