My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
BILLING 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2023 10:34:31 AM
Creation date
11/7/2018 12:01:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2012-2015
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1434\PR0231465\BILLING 2012-2015.PDF
QuestysFileName
BILLING 2012-2015
QuestysRecordDate
6/26/2017 3:07:01 PM
QuestysRecordID
3465007
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN— (Page 2 of 2) <br /> VI. UNDER DISPENSER CONTAINMENT (UDC)MONITORING hata a pply <br /> that ) <br /> UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br /> ® 1.CONTINUOUS ELECTRONIC MONITORING ❑ 2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE 490.54¢. <br /> 490.546. <br /> ❑ 4.NO DISPENSERS _❑ 99.OTHER(Specify) 49.56. <br /> Oso ss. <br /> LEAK MONITOR MANUFACTURER:V@@der-Root MODEL#:TLS-350 <br /> 490-Sa, <br /> LEAK SENSOR MANUFACTURER: V¢¢d¢r-Root _ 490-5). 490-S9, <br /> #(S):0794380-2OR <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ® a,YES ❑ b.NO 49o-s9. <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO °9P60' <br /> FAILUREMISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. M a.YES ❑ b.NO 490.fi1. <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. ❑ a.YES ® b.NO 49061 <br /> UDC CONSTRUCTION IS: ® I.SINGLE WALL ❑ 2.DOUBLE WALL 490-61 <br /> 49oaaa <br /> IF DOUBLE WALL: <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ a.LIQUID ❑ b.PRESSURE ❑ c.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ❑ a.YES ❑ b.NO 490-fi4L' <br /> VII. PERIODIC SYSTEM TESTING <br /> ❑ 1.ELD TESTING: THIS FACILITY—HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 490-6sLEAK . <br /> IT <br /> D TECTION ELD MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED.[23 cCRg2644.t1 <br /> ® 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490 6. <br /> 490-fi7. <br /> ® 3.SPILL BUCKETS ARE TESTED ANNUALLY. <br /> VIII. RECORD KEEPING <br /> The following monitoring/maintenance records are kept for this facility: 49o43. <br /> ® a.ALARM LOGS ❑ b.VISUAL INSPECTION RECORDS ❑ c.TANK INTEGRITY TESTING RESULTS <br /> ❑ d.SIR TESTING RESULTS(and supporting documentation records) ❑ e.TANK GAUGING RESULTS(and supporting documentation records) <br /> ❑ f.ATG TESTING RESULTS(and supporting documentation records) ❑ g.CORROSION PROTECTION 60-DAY LOGS <br /> ® h.E UIPMENT MAINTENANCE AND CALIBRATION RECORDS <br /> IX. TRAINING <br /> Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to theirjob duties: 490.69. <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) 490'696. <br /> ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) 490. . <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490b9d <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 4966th. <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL. AND 49069r. <br /> STATISTICAL INVENTORY RECONCILIATION- 4q 691 <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" 4W69h <br /> ❑ OTHER(Specify): 4W69L <br /> This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council 490.70. <br /> (ICC). The "Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 <br /> days of hire.This training will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> ➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br /> • The facility employee's role with regard to spills and overfills as specified in the facility's UST Response Plan. <br /> D Names)of contact person(s)for emergencies and monitoring alarms. <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. 490.7 1_ <br /> Overfill 95%mechanical flapper <br /> XI. PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that:1.)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered <br /> by this plan occurs',2,)all conditions that indicate a possiblerelease are investigated;and 3 J all To.tarn$records aro maintained_properly__ <br /> THE FOLLOWING PERSON(S)ARE RESPONSIBLE FOR PERFORMING THE MONITORING AND EQUIPMENT MAINTENANCE: <br /> NAME: Paul Chevalier 490-7x TITLE:Maintenance Manager/Designated Operator 490" <br /> NAME: Romy Quiroz 490-14 TITLE:Zone Manager 990-19" <br /> The Designated UST Operator shall perform a monthly visual inspection of the facility,provide a report to the owner/operator,and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> `_II. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the inform at' n provided herein is true and accurate to the best of m knowledge. <br /> APPLICANT SIGNATURE DATE: 490-77. <br /> Jan 4, 2012 <br /> R FLESEN 01®I.Tuan O r/0¢razor®2.F2610 O nerl0 razor❑2.Awh9dttd M entuiW UE-9 490.]6. <br /> APPLICANT NAME(print): 490.15. APPLICANT TITLE: 09079' <br /> Paul Chevalier Maintenance Manager <br /> UPCF UST-D(12/2007)-3/4 www.unidocaorg <br />