INSTALL TANK TOP UPGRADE PLAN 1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
INSTALL TANK TOP UPGRADE PLAN 1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:25 PM
Creation date
11/7/2018 12:06:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
TANK TOP UPGRADE PLAN 1997
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1700\PR0231454\TANK TOP UPGRADE PLAN 1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> A B C D E F <br /> GENERAL NOTES <br /> 1ALL UNUSED TANK OPENINGS SHALL BE TIGHTLY <br /> S P I L L C 0 N T A I N M F N T S U M P S P I L L C O N T A I N M E N T S U M P . <br /> SECURED WITH PIPE PLUG, INSTALLED IN ACCORDANCE <br /> -- WITH MANUFACTURERS SPECIFICATIONS. <br /> 2. ALL LOCKABLE CAPS SHALL HAVE PADLOCKS KEYED <br /> —► 16" -'+-- 4" STEEL PLUG (TYP) ALIKE WITH THE EXCEPTION OF THE "FILL" CAP <br /> 3"x24" M x FEMALE FLEXING CONNECTOR (2 TYP) <br /> 3. TANKS SHALL BE TESTED AND INSTALLED IN <br /> 3" SUMP PIPING PENETRATION <br /> ACCORDANCE WITH MANUFACTURERS RECOMMENDA- 1 <br /> 4" STEEL PLUG (TYR) TIONS AS WELL AS LOCAL ORDINANCES-SEE DWG. J-0.1. <br /> VAPOR CAP & 3"x4" DRY BREAK ADAPTOR 3" SINGLE WALL PHASE II VAPOR RETURN <br /> LINE FROM DISPENSER ISLAND 4. ALL CONTAINMENT SUMP ASSEMBLIES SHALL BE <br /> 4"x4" FILL CAP AND ADAPTOR <br /> FIBERGLASSED INSIDE & OUTSIDE TO TANK RING AND <br /> CAPABLE OF WITHSTANDING HYDROSTATIC TESTING. <br /> i • CONTAINMENT SUMP ASSEMBLIES WILL BE INSTALLED <br /> • TANK LEVEL PROBE BY AMERICAN CONTAINMENT WHICH WILL ACT AS A <br /> RISER & CAP <br /> a 3/4" SUMP CONDUIT PENTRATION SUBCONTRACTOR 70 THE GENERAL CONTRACTOR. <br /> n JUNCTION BOX (NP BOTH SUMPS) I 1 3/4" CONDUIT FOR SUBMERSIBLE PUMP POWER (SEE NOTE 8) CALL (800) 555-6785 TO SCHEDULE. <br /> m 1" SUMP CONDUIT PENETRATION GENERAL CONTRACTOR WILL PERFORM HYDROSTATIC <br /> I VARIABLE LENGTH TURBINE HEAD & ADJUST LENGTH PER MANUFACTURERS INSTRUCTIONS TEST AFTER INSTALLING PENETRATION FITTINGS <br /> AND ASSOCIATED PIPING / CONDUIT. <br /> n I N SUMP LEAK DETECTOR SENSOR 2" BALL VALVE <br /> 5. ASSURE UNUSED PORTS ARE PLUGGED ON <br /> 2" SUMP PIPING PENETRATION <br /> 1" CONDUIT SEE NOTE 8 / TURBINE AND LEAK DETECTOR. <br /> 2" SINGLE WALL FIBERGLASS TANK VENT 6_ LOW AND HIGH VOLTAGE LINES SHALL BE RUN IN <br /> 4" STEEL PLUG (NP) I 3" SUMP PIPING PENETRATION SEPARATE DEDICATED CONDUITS. <br /> 4" EXTRACTOR CAP 4"x4"x3"x2" EXTRACTOR VALVE <br /> 7 ALL STEEL PIPING INSIDE SPILL CONTAINMENT SUMP <br /> TANK ANNULUS SENSOR RISER & CAP ASSEMBLY - PLUG UNUSED OPENING (2 TYP) I 2" FIBERGLASS PRODUCT PIPING LINE WITH ASSEMBLY SHALL BE SCH. 40 BLACK IRON, INCLUDING <br /> _ 1" CONDUIT FROM MONITOR PANELTO J-BOX (SEE NOTE 8 & 15) 1 I , i I 3" FIBERGLASS SECONDARY CONTAINMENT PIPE ALL 4" RISERS. (NO GALVANIZED PIPING) <br /> 36" DIA, FILL BOX & COVER WITH SPILL CONTAINMENT a FILL 36" DIA SUB-PUMP MANWAY <br /> r I I , B. ROUTE CONDUITS ALONG INSIDE PERIMETER OF SUMP TO <br /> FILL BOX WITH DRAIN VALVE R FILL/)/APOR RECOVERY MANWAY & CONTAINMENT SUMPI SUB PUMP MANWAY CONTAINMENT SUMP , PROVIDE EASE OF ACCESS TO PIPING IN THE FUTURE. <br /> SEE DETAIL J-1.1 <br /> SEE DETAIL J-1.1 HASE 1 VAPOR RECOVERY I 1 12 FOR CONDUIT SCHEMATIC SEE DWG. J-8, <br /> 1p,` 8"MIN. TO 18" MAX. .CLEARANCE FROM MANWAY <br /> 12" 24" SLOPE (TYP) i I I I 4" MIN. 6" MAX. CLEARANCE FROM FILL & VAPOR CAP TO SNAP TI7E LID � I TO RISER CAPS & SUB-PUMP A/C PAVING 9. ALL JUNCTION BOXES TO BE EXPLOSION PROOF WITH <br /> 2" CROWN (TYP) <br /> - - - — — — — — — — (TYP BOTH SIDES) UNION HUBS, CROUSE-HINDS GUAG77JUNCTION <br /> BOXES U SUMP WALL SHOULD BE MOUNTED <br /> NTED T <br /> HIGH AS POSSIBLE FOR EASE OF SERVICING. <br /> - - - - � - 91 <br /> — <br /> / I 10, ALL CONDUITS TO HAVE SEAL-OFFS PER LATEST EDITION <br /> OF THE NATIONAL ELECTRICAL CODE <br /> INSTALL MECHANICAL LEAK DETECTOR PER <br /> MANUFACTURERS INSTRUCTIONS rim <br /> PAVIN BASE IT. USE CABLE CONNECTOR FITTINGS (CROUSE-HINDS CGB OR <br /> 4" BLACK IRON RISER BY CONTRACTOR <br /> (TYP BO H SIDES) APPROVED EQUAL) AT MONITOR & LEVEL GAUGE CABLE <br /> i , I CONNECTIONS TO J-BOXES & PIPE FITTINGS. <br /> JUNCTION BOX (ttP BOTH SUMPS SEE NOTE 9) i ( I 3"x2" REDUCING TEST BOOT (SEE NOTE i6) <br /> EYESEAL OFF (TYP BOTH SUMPS) I 3/4" SUMP CONDUIT PENETRATION MINIMUM 5'-0"-MAXIMUM 7'-0" 12. ALL CONDUIT AND PIPING TO PENETRATE SUMPS <br /> I t I I SEE SITE SPECIFIC PERPENDICULAR TO SUMP WALL. 2 <br /> 3/4" CONDUIT FOR SUBMERSIBLE PUMP (SEE NOTE 8) BURIAL DEPTH CALCULATION 13. WHEN INSTALLING FILL BOX, CONTRACTOR IS TO ASSURE <br /> 3" SUMP PIPING PENETRATION THAT THE SPACE BETWEEN THE FILL BOX SKIRT AND THE <br /> I" SUMP CONDUIT PENETRATION I i I 1" SUMP CONDUIT PENETRATION I ON GENERAL PIPING PLAN TOP OF THE CONTAINMENT SUMP IS EQUALLY SPACED <br /> 1" CONDOR FROM MONITOR PANEL 2" FIBERGLASS PRODUCT PIPING LINE WITH <br /> TO J-BOX (SEE NOTE 8 & 15) -- I _ 3" FIBERGLASS SECONDARY CONTAINMENT PIPE ALL AROUND. PROVIDE ADEQUATE SUPPORT FOR FILL <br /> I I 3" SUMP PIPING PENETRATION I I I I BOX DURING CONCRETE INSTALLATION SUCH THAT FILL <br /> _ DROP TUBE WITH OVERFILL PROTECTION I I I 3" SINGLE WALL PHASE II VAPOR I _ 2" SINGLE WALL FIBERGLASS TANK VENT BOX DOES NOT MOVE RELATIVE E CONTAINMENT SUMP. <br /> RETURN FROM DISPENSER ISLAND 1 2" SUMP PIPING PENETRATION (NP BOTH SIDES) CONTAINMENT SUMP LID MUST BE INSTALLED ON TURBINE <br /> 42" TANK COLLAR (TYP BOTH SUMPS) I I 1 III CONTAINMENT SUMP TO ASSURE THAT NO WATER ENTRY <br /> I III CAN OCCUR. <br /> LOCATION FOR TANK HOLD DOWNS (4 NP) , 14. ALL PIPING TO SLOPE DOWN TOWARD TANKS AT A <br /> MINIMUM OF 1/4" PER FOOT. <br /> Z 15. MONITOR CONDUIT MAY ENTER TURBINE SUMP FIRST <br /> ' II O DEPENDENT ON SITE ARRANGEMENT AND TANK <br /> 0 L I I I I I LOCATIONS. <br /> j L I I II I U 16. UNCLAMP TEST BOOT AFTER TESTING SECONDARY PIPING. <br /> L I II II I x <br /> Ld <br /> w i L II I I II j1 I o UNDERGROUND STORAGE TANKS <br /> I I I II I <br /> I I L I I II II I APPROVED DOUBLE WALL FIBERGLASS TANKS <br /> I L I I I II I I J ARE PER DWG, J-0.1, MATERIAL FURNISHED BY <br /> II I 76 PRODUCTS CO. <br /> I I I I II it I SEE GENERAL ARRANGEMENT DRAWING FOR QUANTITY AND <br /> L I I I I I LOCATION OF TANKS. <br /> L I I I II I UNLEADED GASOLINE STORAGE TANKS <br /> I I I I I I I <br /> TANK SHALL BE INSTALLED PER SITE SPECIFIC BURIAL DEPTH <br /> I I I I II II I CALCULATION AS SHOWN ON DRAWING J-0.1. TANKS MUST <br /> NOT BE BURIED DEEPER THAN 7 FEET. THERE SHALL BE <br /> L I I I I I I18 INCHES MIN. BETWEEN TANKS. <br /> I I I <br /> 10'-4" <br /> TANKS SHALL BE INSTALLED WITH A CRANE ONLY, <br /> OUTSIDE DIAMETER CRANE SHOULD BE ADEQUATELY SIZED TO <br /> ACCOMODATE TANK SIZES SPECIFIED ON THE GENERAL <br /> L I I I II II I ARRANGEMENT DRAWING AND WEIGHTS AS INDICATED IN THE <br /> 3 I I I I I I I II II I TABLES HEREON. TANKS SHALL BE SET ON A FIRM BASE OF 12" <br /> WASHED PEA GRAVEL AND SURROUNDED ON ALL SIDES BY A <br /> I- I I I I I MINIMUM THICKNESS 18" OF WASHED PEA GRAVEL. <br /> I L <br /> I I I I I II II I <br /> I I I L I � I II II I <br /> I I I II I I CONTRACTOR SHALL INSTALL FILL RISER AND LEVEL TANK TO <br /> 1/4" THICK STRIKER PLATE UNDER II I I I I I_ KEEP RISER STRAIGHT BEFORE PROCEEDING TO BACKFILL. <br /> PERSONNEL CHECKING LEVEL SHALL BE LOWERED TO TANK <br /> I I L ALL TANK OPENINGS j , TOP IN SAFETY HARNESS. <br /> (FURNISHED BY TANK MANUFACTURER) I FOR ADDITIONAL INFORMATION SEE DWG. J-0.1, J-0.2, J-0.2A <br /> L I <br /> TANK SPECIFICATIONS <br /> XERXES CORPORATION <br /> 4-6 , I — 87 T� <br /> I _ CAPACITYGALS. _ .. <br /> ACTU ) <br /> 1 <br /> 12" PEA GRAVEL TANK BED (SEE J _011 <br /> I— — OUTER DIA. 10'-4" <br /> 15,000 <br /> (14 976 GAL. AL <br /> I — LENGTH 29 5 3/4" <br /> -II S E T T A N K L E V E L ( D O N O T S L O P E ) - <br /> -1 —I I I WEIGHT 6,100 IBS. (APPROX) <br /> I-iii- I I . . , I I ,�11 �_ I I-� i i_ I <br /> ANNULUS LEAN( DETECTOR SENSOR AT BOTTOM CENTER OF TANK MAGNETOSTRICTIVE PROBE —1 I 1-1 I—i I <br /> 92 TAN <br /> CONTRACTOR TO FIELD CUT LOWER END OF FILL TUBE VARIABLE LENGTH SUBMERSIBLE PUMP CAPACITY 12,000 GALS. <br /> AT A 45• ANGLE & INSTALL PER MANUFACTURERS INSTRUCTIONS (11,849 GAL. ACTUAL) <br /> LENGTH 24'-0 1/4" <br /> 29'-5 3/4" (15,000 GALLON TANK) 1 -g OUTER DIA. 10'-4" <br /> 24'-0 1 /4 ' (12,000 GALLON TANK) WEIGHT 4,950 LBS. (APPROX) <br /> T Y P I C A L P R O D U C T TAN K — ELEVATION USE APPLICABLE SECTIONS ONLY <br /> 4 REV DATE REVISED <br /> DESTROY�rz o e 41E APPROVAL RECORD DRWH 9Y APPROVALS UNLEADED GASOLINE <br /> © UNION OIL OF CALIFORNIA, dba UNOCAL, 1994 RH <br /> THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN IS ISSUED FOR C.U.P. CHECKED BY UNDERGROUND FUEL TANK INSTALLATION <br /> PROPRIETARY TO UNION OIL OF CALIFORNIA (UNOCAL) AND HAS ( °w+mnew W ) °,,� TYPICAL OF 87 TANKS <br /> BEEN FURNISHED IN CONFIDENCE AND ARE SUBJECT TO THE ISSUED FOR PLAN CHECK <br /> TERMS OF A SEPARATE SECRECY AGREEMENT BETWEEN UNOCAL ISSUED FOR GEN. BID D <br /> AND THE RECIPIENT. THE RECIPIENT IS NOT TO COPY, DUPLICATE DATE _!/8/97 �"�SA ° �1 °�wm NO. Rn _ <br /> OR DISCLOSE THE CONTENTS TO ANY PERSON OR ENTITY EXCEPT ISSUED FOR CONSTRUCT. S <br /> AS EXPRESSLY AUTHORIZED BY SAID AGREEMENT OR BY UNOCAL PRODUCTS COMPANY _ 0 OF SIRF*S <br /> " - (aro�pd wu�1 <br /> IN WRITING. RECORD DRAWING 3 4 - ( — _ <br /> I � <br />