My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2006 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2115
>
2300 - Underground Storage Tank Program
>
PR0526335
>
BILLING 2006 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 11:53:42 AM
Creation date
11/7/2018 12:12:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2006 - 2008
RECORD_ID
PR0526335
PE
2351
FACILITY_ID
FA0017819
FACILITY_NAME
7 ELEVEN 2369-39858A
STREET_NUMBER
2115
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
2115 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\2115\PR0526335\BILLING 2006 - 2008.PDF
QuestysFileName
BILLING 2006 - 2008
QuestysRecordDate
6/22/2016 6:54:53 PM
QuestysRecordID
3124912
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U IFIED PROGRAM CONSOLIDATED FORM � <br /> UNDERGROUND STORAGE TANK U lE �D <br /> MONITORING PLAN- (Pae I of 3) U <br /> TYPE OF ACTION ® 1.NEW PLAN [12.CHANGE OF INFORMATION <br /> L 5 2008 490-1, <br /> 490-x. <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTS AT THIS FACILITY. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): ENVIRONMENT HEALTH 490-3-3 <br /> I. FACILITY INFORMATION ` <br /> FACILITY ID#(Agency Use Only) I <br /> 3. <br /> BUSINESS NAME(Same as Facility Name or DBA) GASSPECS, INC. dba GREAT AMERICAN GAS &CAR WASH <br /> BUSINESS SITE ADDRESS 103. BUSINESS SITE CITY 1M. <br /> 2115 W.Yosemite Ave. Manteca <br /> H. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(eg.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> the equyment manufacturers'mswe[ions,or annually,whichever is more frequent Such work,must be performed by qualifiedpersonnel.,lz3 CCR§2632 2634,263x,zsall_ <br /> ._.__. -.. .... .. 490-3. <br /> MONITORING EQUIPMENT IS SERVICED ® 1 ANNUALLY ❑ 99 OTHER(Specify): 490-3b <br /> HI. MONITORING LOCATIONS <br /> ® 904 <br /> 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED I23 cert§2612,26341 <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) �heack(ll <br /> ® 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,26341 <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY ® b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM d9)4 <br /> PANEL MANUFACTURER: Veeder Root 490.2 MODEL#: TLS-360 490-8, <br /> LEAK SENSOR MANUFACTURER: Veeder Root " MODEL#(S): 794380303 4WI0. <br /> ._-________...____ ____...._. ..._.......__..._......_....M3] <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED]b MONITOR SINGLE WALL TANK($).[23 ccR§2643] 490-1I. <br /> PANEL MANUFACTURER: 490-12 MODEL#: 4".13. <br /> IN-TANK PROBE MANUFACTURER: 490.14MODEL#(S): 49x-15. <br /> LEAK TEST FREQUENCY: ❑ &CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): °90-1Y_ <br /> PROGRAMMED TESTS: ❑ a.0.1 h. ❑ b.0.2 h. ❑ c.OTHEROso-le. <br /> . .....g.? . ........_._.___.__g.p.h. (Specify).... 69090- <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION Iz3 ccR§2646.❑ 490-20. <br /> ❑ 4.WEEKLY MANUAL TANKGAUGING(MTG)[23CCR§2651 TESTINGPERIOD ❑ a 36HOURS ❑ b 6011GURS 49 22 v_ <br /> ❑ S.TANK INTEGRITY TESTING PER[23 CCR§x643.11490-23 <br /> 90-24. <br /> TEST FREQUENCY ❑ a ANNUALLY ❑ b BIENNIALLY ❑ c.OTHER(Specify):_. 490 25 <br /> ---- ........... .......-------_ .......... ....._.._..._ _.._._........ ........... .... <br /> 490-26 <br /> ❑ <br /> 99.OTHER(Specify): 490-27 <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Caheack all <br /> ® L CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490'28. <br /> I§2636 SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-29. <br /> PANEL MANUFACTURER:Veeder Root 490.30. MODEL#: TLS-350 4%-31. <br /> LEAK SENSOR MANUFACTURER: Veeder Root 4W32 MODEL#(S): 794380-208 4"-33 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® ..YES ❑ b.NO 4so-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHU'T'DOWN. ® a.YES ❑ b.NO 490-3s. <br /> ....__.__ _ .______ ._....._. ____.._.._.._ __.__.___ .._....... ..__._._ .__.__,__.__.... <br /> �] 2.MECHANICAL LINE LEAK DETECTOR(MELD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 496-36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.I23 CM§2636] <br /> MELD MANUFACTURER(S): ' MODEL#(S); 490-38. <br /> ® 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCR§26361 490'19' <br /> ELLD MANUFACTURER(S):Veeder Root 49 40. MODEL#(S): 848480-001 49P41_ <br /> PROGRAMMED IN LINE LEAK TEST: ® a.MINIMUM MONTHLY 0.2 g.p.h ❑ b.MINIMUM ANNUAL 0.1 g.p.E 490.42. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 49043. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a YES ❑ b.NO 49044_ <br /> ❑ 4.PIPE INTEGRITY TESTING. 49045. <br /> TEST FREQUENCY: ❑ a ANNUALLY ❑ b.EVERY 3 YEARS ® a OTHER(Specify) Continuous 490 a°-46. <br /> ❑ 5.VISUAL PIPE MONITORING. 49048. <br /> FREQUENCY: ❑ 8_DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED' 49x-49. <br /> 'aa aro mo0a & r bnea.,gire.& x& ..�LvrNl➢P .&...^.!x.eer HSC§zszalatbJ016........____ <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA [23 CCR§263610)(3/1 4s0-50_ <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.715 CONNECTED TO THE TANK SYSTEM 490-51- <br /> . _.------- .... ...._.__._ .......-----... ......_ ............. ............ .................. ........... .............. .................. ........._... . ......._ <br /> 0-526 <br /> ❑ 99.OTHER(Specify) 4"-53 <br /> .3Q / --)4Z <br />
The URL can be used to link to this page
Your browser does not support the video tag.