My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 9:30:02 AM
Creation date
11/7/2018 12:23:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\707\PR0505151\COMPLIANCE INFO 2013 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
7/19/2016 10:55:15 PM
QuestysRecordID
3146588
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> SWRCB,January 2002 PaPEC 14 2015 <br /> 5. SECONDARY PIPE TESTING TAL <br /> Test Method Developed By: X Piping Manufacturer ❑Industry Standard ❑Pro fession wj PPApT FNT <br /> ❑Other(Spec) <br /> Test Method Used: X Pressure ❑Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Pressure Gauges in Psi/Nitrogen Equipment Resolution: 1/10-15 Psi <br /> Piping Run#1 Piping Run 42 Piping Run#3 Piping Run# <br /> Piping Material: Fiberglass Fiberglass Fiberglass <br /> Piping Manufacturer: Smith Smith Smith <br /> Piping Diameter: 3" 3" 3" <br /> Length of Piping Run: Approx. 100' Approx. 110' Approx.50' <br /> Product Stored: Regular 87 Regular 87 Diesel <br /> Method and location of Test boot at STP Test boot at STP Test boot at STP <br /> i in -run isolation: Piping Sump#1 Piping Sump#2 Piping Sump 43 <br /> Wait time between applying 15 Minutes 15 Minutes 15 Minutes <br /> pressure and startin test: <br /> Test Start Time: 9:30 9:50 9:55 <br /> Initial Reading(Ri): 5 Psi 5 Psi 5 Psi <br /> Test End Time: 10:30 10:00 10:10 <br /> Final Reading(RF): 2 Psi 0 Psi 0 Psi <br /> Test Duration: 1 Hour 10 Minutes 15 Minutes <br /> Change in Reading(RF-Rj): 3 Psi 5 Psi 5 Psi <br /> Pass/Fail Threshold or No detectable loss No detectable loss No detectable loss <br /> Criteria: <br /> Test Result: Fail Fail Fail <br /> Comments— (include information on repairs made prior to testing and recommended follow-up forfailed tests) <br /> Recommended repairs. <br /> Test boot for Tank#1 Regular 87 at Piping Sump. <br /> Test boot for Tank#2 Regular 87 at Piping Sump&at UDC#7&8. <br /> Test boot for Tank#3 Diesel at UDC#7&8. <br /> See comments below: <br /> Secondary Pipe#1 Tank#187 Regular has a small loss on Test boot Schrader Valve washer seal,in Piping Sump. <br /> Previous repair to this area on test boot. Unable to stop loss. Recommend a new test boot. <br /> Secondary Pipe#2 Tank#2 87 Regular test boot began to split apart 10 minutes after pressure was applied. <br /> Also found the test boot at UDC&7&8 for this Secondary Pipe has large cracks and shows bubbles it UDC Test water. <br /> Secondary Pipe#3 Diesel,will not maintain pressure due to test boot at UDC#7&8. Found large cracks on Test Boot, <br /> Bubbles flowing from this test boot in UDC#7&8 Test water. Recommend a new test boot. <br /> Recommend a repair contractor be consulted. <br />