Laserfiche WebLink
\ San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone:(209)468-3420 Fax: (209) 468-3433 Web:www.sicloy.orq/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> -1UICKI KLEEN CAR WASH 209 823-9159 C RSID:tobe21, 2015 <br /> CERS W: <br /> Facility Address: 10182307 <br /> 707 E YC" ''ITE AVE MANTECA CA 95336 <br /> Inspection Contact: Title: Phone: <br /> _.. .;� <br /> Mager <br /> Inspection Type: program• <br /> ^TION- O eratin Permit 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> Dx Inspection Photos O Samoles I Genaro Deanda Mana er <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Feh, 03/03/2016 Zane Nimmo 03/03/2016 <br /> Service Technician Manufacturers Training <br /> VMI. 11/11 VR,07/07/16: TT,12/31/-14 <br /> omia egu at ons =Flea a erye C = ode of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate o V ❑R o COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system o V ❑R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ❑V ❑R ❑COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current ❑V o R ❑COS <br /> 105 HSC 25286(c) Current BOE number not submitted ❑V o R ❑COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD ■V o R ❑COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ❑V o R ❑COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing ❑V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment ❑V ❑R o COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days o V ❑R ❑COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually o V oft ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ❑V ❑R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ■V ❑R ❑COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shutdown ❑V ❑R o COS <br /> 115 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days ❑V ❑R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification ❑V ❑R ❑COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well ❑V oft ❑COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test ❑V ❑R ❑COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days ❑V ❑R o COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V ❑R ❑COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V ❑R ❑COS <br /> 122 HSC 25299 Documents were falsified or misrepresented o V ❑R o COS <br /> 123 CCR 2661 Permit to repair UST system not obtained ❑V ❑R ❑COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V o R ❑COS <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V ❑R o COS <br /> Received Inspector: Phone: Date: <br /> (initial): ELENA MANZO, Senior REHS (209) 953-7699 10/21/2015 <br /> Page of6 <br />