My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 9:30:02 AM
Creation date
11/7/2018 12:23:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\707\PR0505151\COMPLIANCE INFO 2013 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
7/19/2016 10:55:15 PM
QuestysRecordID
3146588
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County .s <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone. (209) 458-3420 Fax: (209) 468-3433 Web:www Slaov ora/ehtl <br /> Underground Storage Tank Program Inspection Report <br /> FacilAy Name: <br /> Facility Address: Date: <br /> _ <br /> QUICKI KLEEN CAR WASH "1 i - './E <br /> File Review <br /> 126 HSC 25404(e)(4) Failed to report program data electronically ❑V-,R -COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm"a end/or records of follow up actions I ■V ❑R o COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years ❑V ❑R ❑COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site ❑V o R ❑COS <br /> 204 CCR 2712(1) Current monttoring plan approved by the EMD not found on site ■V ❑R o COS <br /> 205 CCR 2712(1) Operating permit not on site o V n R o COS <br /> 206 HSC 25294,25295 Failed to record or report unauthorized release in appropriate time frame o V o R ❑COS <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed ■V o R ❑COS <br /> 208 CCR 2715 I Designated operator monthly inspection reports not maintained on site for at least 12 months ■V ■R ❑COS <br /> 2D9 CCR 2715(f) Designated operator employee training not performed or log not kept o V ❑R o COS <br /> 210 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD ❑V ❑R ❑COS <br /> 211 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept o V o R o COS <br /> 212 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept o V o R ❑COS <br /> UST System Observations <br /> F3O5 <br /> HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overrias o V o R o COS <br /> HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) ❑V o R ❑COS <br /> HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003Jun 2004) ❑V o R ❑COS <br /> HSC 26290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) o V ❑R v COS <br /> HSC 25290.1(a) VPH monitoring of the interstitial spaces of the UST system is not maintained n V o R ❑COS <br /> CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity ❑V o R o COS <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained o V o R o COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm o V ❑R o COS <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC o V ❑R 0 COS <br /> 310 CCR 2636(f)(1) Sensor in a turbine sump failed to activate an audible and visual alar or stop the flow product o V u R o COS <br /> 311 CCR 2636(0(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs ❑V 0 R o COS <br /> 312 CCR 2636 Failed to properly program or operate leak detection equipment ❑V o R ❑COS <br /> 313 CCR 2638(f) Faiked to affix a tag sticker on monitoring equipment certified,repaired,or replaced u V o R o COS <br /> 314 CCR 2631(a) Primary containment not tight(pre-Jul 2003) ❑V o R ❑COS <br /> 315 HSC 25290.2(c)(1) Primary containment not tight(Jul 2003Jun2004) ❑V o R o COS <br /> 316 HSC 25290.1(c)(1) Primary containment not tight(after Jun 2004) o V ❑R o COS <br /> 317 HSC 25290.1,25290.2, Secondary containment not tight o V 0 R o COS <br /> 25291 <br /> 318 CCR 2636(a) Failed to have secondary containment 0 V ❑R o COS <br /> Received bA Inspector: Phone: Date: <br /> (initial): ELENA MANZO, Senior REHS (209) 953-7699 10/21/2015 <br /> pal2 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.