Laserfiche WebLink
San Joaquin County �1111111F <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Califomia95205-6232 <br /> Telephone:(209) 468-3420 Fax: (209)468-3433 Web:www sioov.oro/ehd <br /> Underground Storage Tank Program Inspection Report <br /> FaciRy Nama: Facility Address: Date: <br /> CUICKI KLEEN CAR WASH 707 E Y( -CA Oc <br /> UST System Observations <br /> 319 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) ■V ❑R ❑COS <br /> 320 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion ❑V ❑R ❑COS <br /> 25290.2(c3) <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not Mow to a collection sump ❑V ❑R o COS <br /> 322 CCR 2636(1)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ■V ❑R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty I o V ❑R o COS <br /> 325 CCR 2635(b) Spill container Failed to contain a minimum capacity of Me gallons ❑V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V ❑R ❑COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> 328 HSC 25283.5 Unburied below grade UST Failed to meet exemption status ❑V o R ❑COS <br /> 329 CCR 2717.1(g) Tampered with red tag PRo OS330 CCR2717A(f) Deposited petroleum into a red tagged UST OS331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms OS332 CCR 2631.1 UST system not compatible with the substance stored OS333 HSC 25298(b) Failed to comply with temporary closure requirements COS334 HSC 25298(c) Failed to comply with permanent closure requirements COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V o R ❑COS <br /> 402 CCR 2843(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V o R in COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V o R ❑COS <br /> 2030 See below Unlisted Operetions/Maintenanoe violation ❑V ❑R o COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> Receive Inspector: Phone: Date: <br /> (initial): --LENA MANZO, Senior REHS(ed 1 (209) 953-7699 10/21/2015 <br /> P -of 6 <br />