Laserfiche WebLink
RECI " r <br /> Appendix VI SEEP 3 0 1016 <br /> MONITORING SYSTEM CERTIFICATION ENVIRONMENTAL_ <br /> For Use By All Jurisdictions Within the State of California pF��A� HEALTH <br /> Authority Cited:Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code 9A%6 aG8iil!CFS <br /> This forth must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who perforins the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: QUICK & EASY FOOD MART Bldg.No.: <br /> Site Address: 824 E. YOSEMITE AVE. City: MANTECA zip: 95336 <br /> Facility Contact Person: 11TENDER Contact Phone No.: ( ) <br /> Make/Model of Monitoring System: GILBARCO E M C Date of Testing/Servicing: 6/27/2016 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: 87 Tank Size: Tank ID: 89 Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG I <br /> ® Annular Space or vault Sensor. Model: 420 ® Annular Space or Vault Sensor. Model: 420 <br /> ® Piping Sump/Trench Sensor(s). Model: 2 0 5 ® Piping Sump/Trench Sensor(s). Model: 2 0 5 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: 99 LD 2000 ® Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank Size: Tank ID: 91 Tank Size: <br /> ❑ In-Tank Gauging Probe. Model: ® In-Tank Gauging Probe. Model: MAG 1 <br /> ❑ Annular Space or Vault Sensor. Model: ® Annular Space or Vault Sensor. Model: SAME AS 89 <br /> ❑ Piping Sump/Trench Sensor(s). Model: ® Piping Sump/Trench Sensor(s). Madel: 205 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> 4 Mechanical Line Leak Detector. Model: ® Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ['r Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: I / 2 Dispenser ID: 3 / 4 <br /> ® Dispenser Containment Sensor(s). Model: 2 0 8 ® Dispenser Containment Sensor(s). Model: 2 0 8 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5 / 6 Dispenser ID: 7 / 8 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 2 0 8 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): 19 System set-up ®Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2n0 STREET GALT,CA 95632 Date of Testing/Servicing: 6/27/2016 <br /> Monitoring System Certification Page t of 4 2/21/07 <br />