My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1986-2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
420
>
2300 - Underground Storage Tank Program
>
PR0231458
>
COMPLIANCE INFO 1986-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 2:50:21 PM
Creation date
11/7/2018 1:12:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2001
RECORD_ID
PR0231458
PE
2361
FACILITY_ID
FA0001196
FACILITY_NAME
SAVE ON FUEL
STREET_NUMBER
420
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
219-312-06
CURRENT_STATUS
01
SITE_LOCATION
420 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\Y\YOSEMITE\420\PR0231458\COMPLIANCE INFO 1986-2001.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENANEERING REPORT <br /> TEST PROCEDURES FOR <br /> / MECHANICAL LEAK DETECTORS <br /> RED JACKET <br /> ' PUMPS <br /> September 1992 <br /> TESTING MECHANICAL LEAK DETECTORS <br /> OPTION A - BASIC FUNCTION EVALUATION <br /> ' The following defined terms are used throughout Red Jacket literature and instructions to bring attention to <br /> the presence of hazards of various risk levels, or to important information concerning the life of the product. <br /> 1 indicates presence of a hazard which will cause were per- indicates presence hazard whichwillorcan cause minor <br /> t ` <br /> conal injury, death or substantial property damage if ig- personal injury or property damage if ignored. <br /> pored. <br /> indicates presence of a hazard which can uuae aeoere per- {s indicates special instructions on installations,operation,or <br /> conal irUury, death or substantial property damage if ig- mainten.mwiichamimportantbutnotmlatedwpemnaI <br /> nored. injury hazards. <br /> AVO DESCRIPTION 2. stated that an annual test of the operation of <br /> the leak detector must be conducted in accor- <br /> This report(RJ-21) provides the procedure for es- dance with the manufacturer's requirements. <br /> tablishing that Red Jacket mechanical leak detec- <br /> tors are functioning utilizing the Apparatus to The EPA requires"...thatthe LLDsbetestedannu- <br /> Verify Operation(AVO).The characteristics of the ally to insure that they are properly installed and <br /> pumping system in which the line leak detector maintained and have not been tampered with and <br /> ' (LLD)is installed will affect its performance.This areoperahngmaccordance withthemanufacturer's <br /> AVO procedure provides some evaluation of the requirements". In addition,to assure maintenance <br /> pumping system as well as the LLD. It can be of leak detector capability, Red Jacket requires <br /> utilized for further evaluation of the pumping sys- that operation of the mechanical leak detector be <br /> tem.Please note that performanceoftheSimu. verified upon start-up and that testing of the leak <br /> lated Leak Test set forth in Section IV will detector be performed routinely—at least annu- <br /> satisfy the minimum functionality check re- ally.Section IV ofOption A(RJ-21)or Section V and <br /> quirements for annual inspection of leak de- VI of Option B (RJ-20) are intended to meet the <br /> tectors. For information on this as well as refer- minimum requirement for verifying the functional- <br /> ence information on the LLD and the pumping ity of the LLD. <br /> ' system in which it is installed, including symp- This report, as well as report RJ-20, provides the <br /> toms, probable causes, suggested action, see Red manufacturer's requirements for testing of Red <br /> Jacket Mechanical Leak Detector Manual,#5191, Jacket LLDs. The procedures covered in this re- <br /> and/or Red Jacket Petroleum Products Service port, and RJ-20, supersedes previous procedures <br /> Manual, #5190. for testing Red Jacket LLDs. <br /> Option B in Report RJ-20, utilizing the Field Test � Competent mechanical leak de- <br /> Apparatus (FTA), will provide a more finite ap- <br /> proach to testing the Red Jacket LLD that allows tector evaluation requires A) <br /> more consistent comparisons of leak rates thatmay that testing be performed by <br /> be used as a management and maintenance tool for trained,qualified personnel and <br /> ' populations of leak detectors. B)consistent,proper procedures <br /> involving good maintenance, <br /> Under 40CFR280.44(a), EPA has quality control and calibration <br /> ' I. defined performance standards for automatic of equipment are utilized. <br /> LLDs(out-of-the-box)prior to installation.Red Education on this and all technical aspects of Red <br /> Jacket mechanical leak detectors have been Jacket petroleum submersible pumping and moni- <br /> ' constructed to meet the EPA requirements as toring systems is available via our TECHS pro- <br /> outlinedin 40CFR280.44(a).Acopyof ourthird- gram. <br /> party certifications is available upon request. <br /> ' 1 RJ-21© 9/92 <br />
The URL can be used to link to this page
Your browser does not support the video tag.