My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1986-2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
420
>
2300 - Underground Storage Tank Program
>
PR0231458
>
COMPLIANCE INFO 1986-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 2:50:21 PM
Creation date
11/7/2018 1:12:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2001
RECORD_ID
PR0231458
PE
2361
FACILITY_ID
FA0001196
FACILITY_NAME
SAVE ON FUEL
STREET_NUMBER
420
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
219-312-06
CURRENT_STATUS
01
SITE_LOCATION
420 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\Y\YOSEMITE\420\PR0231458\COMPLIANCE INFO 1986-2001.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' The Piston-type Leak Detector...3 STEP LEAK TEST <br /> The Red Jacket piston leak detector hour) is metered through the LLD into flow to approximately 1-12 to 3 GPM. <br /> t is a pressure-sensing, piston-operated the piping system. If a leak is present This is the indication to the operator that <br /> valve designed to indicate a leak in the that equals or exceeds this amount,as a leak is present.' <br /> piping between the leak detector and much product escapes from the system If there are no leaks, pressure rapidly <br /> the dispenser. as is metered in through the LLD. builds in the system forcing the LLD to <br /> ' When the line pressure is at approxi- Under this condition pressure cannot open to the full-flow position. In a <br /> mately less than 1 psi and the sub- build up in the piping system. When a system with no leaks, it takes approxi- <br /> merged pump is turned on,a controlled nozzle is opened,a poppet in the LLD mately two seconds for a complete test. <br /> amount of product(three gallons per moves to a position that restricts the No further line testing lakes place until <br /> ' the line pressure drops below 1 psi. <br /> 010 <br /> POSITION 1 POSITION 2 POSntON <br /> 3 s <br /> ' VEMED VEHfED VEWED <br /> TOTO TO <br /> TANK TANK <br /> �. TANK % �/. <br /> PRESSURE p-IIm <br /> RELIEF <br /> VALVE <br /> LESS <br /> PG S4 <br /> 1 { / <br /> ROLL PRESSURE PULL PRESSURE / `PULL PRESSURE <br /> POPPET RPPROY 75 PSI APPPOY IS PSI AIPMY 55 Pa <br /> E�PAOY PMP \ �'�FHDY PWP `•� ��PROY PWP <br /> YEIEREKL PN \\V \\\ <br /> \` <br /> LESSTh <br /> 1PEI + <br /> ' �TO CISDHAMELWE ♦TO DISCHARGE UIE �aIEDRAROE IriE <br /> 1. The Trip or Relaxed Position.Under 2. Leak Sensing Position.As the pressure If there is no leakage in the system,the <br /> ' normal operating conditions,it is assumed builds to approximately 20 to 22 psi small flow around the metering pin <br /> that the lines are filled with gasoline. (rapidly)the piston has moved the poppet increases the line pressure to 22 psi in <br /> When the system pressure is less than 1 to such a position as to almost stop the approximately two seconds at which point <br /> psi,the piston and poppet are in their flow into the piping through the LLD valve the piston will snap the poppet to Position <br /> "down-or'tripped"position.The position poppet In this position,all the flow must 3,allowing full flow.Any product relieved <br /> of the valve poppet is such as to allow then travel around the metering pin which through pressure relief valve during trip <br /> approximately 1-1/2 to 3 GPM flow into limits it to approximately 3 GPH rate.If a position will be vented through vent tube <br /> the delivery line through a bypass simultaneous loss from the system equals to tank.This allows piston to move freely <br /> opening in the LLD valve poppet when or exceeds this amount,the line pressure with no back pressure to hamper its <br /> ' the submersible pump starts.Since the will not build beyond this point and the movement. <br /> system is full,pressure builds rapidly and valve will remain in the leak sensing 3. Non-leak Position.This position allows <br /> the poppet moves to the leak sensing position with the main flow blocked. If full flow.The poppet will remain in this <br /> position assuming there is no leak there is an attempt to dispense while the position as long as the system pressure <br /> ' present.The pressure relief valve valve is in this position,the line pressure remains above 1 psi.At less than i psi, <br /> prevents any build up of pressure under will drop..the piston will respond,and the the poppet will return to Position 1 and <br /> piston when in trip position by allowing poppet will return to Position 1 where the the next time the pump is activated,the <br /> relief of trapped product. 1-1/2 to 3 GPM will flow to the dispens- LLD will perform a line test. <br /> er5.' <br /> 'If the dispensing system(the solenoid valve and the nozzle)is opened previous to the completion of the line test,the LLD will detect this opening as <br /> a leak and restricted flow will result.Closing of the nozzle(s)fora period of time,adequate to allow completion of the line test,will allow the LLD to open. <br /> This,in tum,will allow full flow providing there is no additional escape for fuel in the system. <br /> ' 111Tr977M Per the above process,this product is designed and sold to detect leaks of 3 GPH or greater only. <br /> For leaks of less than 3 GPH, please consult with your Marley Pump Company representative. <br /> ' 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.