Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjaov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JAMAR SERVICE 4075 E MAIN ST, STOCKTON May 01, 2017 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status n V u R u COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements o V o R o COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V c R c COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V c R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(preJanuary 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed (pre-January 1984) ❑V r R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation c V n R u COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> On the Certification of Financial Responsibility form, under Coverage Amount, indicate 5,000 per occurrence and <br /> 5,000 per aggregate, instead of 500 per occurrence and per aggregate. Also, the witness or notary did not include <br /> the date. In the Letter from Chief Financial Officer, line 4"tangible net worth" is incorrect. Current financial <br /> responsibility documents are required to be submitted annually. Immediately log into the California Environmental <br /> Reporting System (CERS)at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a repeat violation, Class II. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> Under the Facility Operating Permit in the California Environmental Reporting System (CERS), the Board of <br /> Equalization(BOE) number 44024816 is closed and is not valid. Immediately contact the BOE and obtain a valid <br /> BOE number. Also, the Property Owner, Tank Owner, and Tank Operator names must be updated and submitted to <br /> CERS. <br /> This is a repeat violation, Class II. <br /> FA0002121 PR0231667 SCO01 05/01/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 5 Underground Storage Tank Program OR <br />