My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4075
>
2300 - Underground Storage Tank Program
>
PR0231667
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2019 4:22:44 PM
Creation date
11/7/2018 5:51:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0231667
PE
2361
FACILITY_ID
FA0002121
FACILITY_NAME
JAMAR SERVICE
STREET_NUMBER
4075
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
15726411
CURRENT_STATUS
01
SITE_LOCATION
4075 E MAIN ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\IAError\M\MAIN\4075\PR0231667\COMPLIANCE INFO 2016-PRESENT .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WS <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sjgov.ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JAMAR SERVICE 4075 E MAIN ST, STOCKTON May 01, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For the monitoring plan of both underground <br /> storage tanks, beneath "Personnel Responsibilities;'the name of the first person having responsibility and their title <br /> must be changed. The monitoring plan must be uploaded to the California Environmental Reporting System <br /> (CERS). Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan. <br /> The response plan is not current and/or not approved by the EHD. In the response plan both names under"Section <br /> IV Responsible Persons" need to be removed and updated. Also, in the response plan, "Section VII Owner/Operator <br /> signature"needs to be updated accordingly. The response plan must be uploaded to the California Environmental <br /> Reporting System (CERS). Immediately log into CERS, upload the completed form, and submit for review by the <br /> EHD. Ensure a copy is available for inspection at any time. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> The site map did not label the 87-and 91-product underground storage tanks. The site map did not indicate the <br /> location of the annular sensor and the location of the line leak detectors. The site map also did not indicate float and <br /> chains at all 4 dispensers. An accurate site plan must be submitted identifying the locations where monitoring will <br /> be performed. Immediately log into the California Environmental Reporting System(CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a repeat violation, Class II. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> The facility failed to document and address the T2: super unleaded probe out alarm on 10/11/16. Ensure the facility <br /> documents and addresses all daily alarms. <br /> This is a minor violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator(DO)failed to label the four dispensers correctly on the designated operator reports for <br /> 6/11/16 and 7111/16. The DO failed to document and address the T2: super unleaded probe out alarm on 10/11/16. <br /> The DO monthly inspection report dated 10/20/16 had a panel print out dated 10/21/16. The DO failed to sign the <br /> 3/7/17 DO monthly inspection report. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> FA0002121 PR0231667 SCO01 05/01/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.